SPECIAL SECTION ON TISSUE POLARIMETRY

Development and calibration of an automated Mueller matrix polarization imaging system

[+] Author Affiliations
Justin S. Baba, Jung-Rae Chung, Aimee H. DeLaughter, Brent D. Cameron, Gerard L. Cote´

Texas A&M University, Biomedical Engineering Program, College Station, Texas?77843-3120

J. Biomed. Opt. 7(3), 341-349 (Jul 01, 2002). doi:10.1117/1.1486248
History: Received Aug. 30, 2001; Revised Mar. 19, 2002; Accepted Apr. 1, 2002; Online August 01, 2002
Text Size: A A A

The high fatality rate associated with the late detection of skin cancer makes early detection crucial in preventing death. The current method for determining if a skin lesion is suspect to cancer is initially based on the patient’s and physician’s subjective observation of the skin lesion. Physicians use a set of parameters called the ABCD (asymmetry, border, color, diameter) rule to help facilitate diagnosis of potential cancerous lesions. Lesions that are suspicious then require a biopsy, which is a painful, invasive, and a time-consuming procedure. In an attempt to reduce the aforementioned undesirable elements currently associated with skin cancer diagnosis, a novel optical polarization-imaging system is described that has the potential to noninvasively detect cancerous lesions. The described system generates the full 16-element Mueller matrix in less than 70 s. The operation of the system was tested in transmission, specular reflection, and diffuse reflectance modes, using known samples, such as a horizontal linear polarizer, a mirror, and a diffuser plate. In addition, it was also used to image a benign lesion on a human subject. The results of the known samples are in good agreement with their theoretical values with an average accuracy of 97.96% and a standard deviation of 0.0084, using 16 polarization images. The system accuracy was further increased to 99.44% with a standard deviation of 0.005, when 36 images were used to generate the Mueller matrix. © 2002 Society of Photo-Optical Instrumentation Engineers.

© 2002 Society of Photo-Optical Instrumentation Engineers

Citation

Justin S. Baba ; Jung-Rae Chung ; Aimee H. DeLaughter ; Brent D. Cameron and Gerard L. Cote´
"Development and calibration of an automated Mueller matrix polarization imaging system", J. Biomed. Opt. 7(3), 341-349 (Jul 01, 2002). ; http://dx.doi.org/10.1117/1.1486248


Tables

Access This Article
Sign in or Create a personal account to Buy this article ($20 for members, $25 for non-members).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging & repositioning the boxes below.

Related Book Chapters

Topic Collections

Advertisement


  • Don't have an account?
  • Subscribe to the SPIE Digital Library
  • Create a FREE account to sign up for Digital Library content alerts and gain access to institutional subscriptions remotely.
Access This Article
Sign in or Create a personal account to Buy this article ($20 for members, $25 for non-members).
Access This Proceeding
Sign in or Create a personal account to Buy this article ($15 for members, $18 for non-members).
Access This Chapter

Access to SPIE eBooks is limited to subscribing institutions and is not available as part of a personal subscription. Print or electronic versions of individual SPIE books may be purchased via SPIE.org.