0
Research Papers

Active retinal tracker for clinical optical coherence tomography systems

[+] Author Affiliations
Lelia Adelina Paunescu, Siobahn Beaton, Hiroshi Ishikawa, Gadi Wollstein, Joel S. Schuman

New England Eye Center, New England Medical Center, 750 Washington Street, Box 450, Boston, Massachusetts 02111

Daniel X. Hammer, R. Daniel Ferguson, John C. Magill

Physical Sciences Inc., 20 New England Business Center, Andover, Massachusetts 01810 E-mail: hammer@psicorp.com

J. Biomed. Opt. 10(2), 024038 (Dec. 18, 2003May 25, 2004Sep. 9, 2004Apr. 13, 2005April 13, 2005). doi:10.1117/1.1896967
History: Received Dec. 18, 2003; Revised May 25, 2004; Accepted Sep. 9, 2004; Apr. 13, 2005; Online April 13, 2005
Text Size: A A A

An active, hardware-based retinal tracker is integrated with a clinical optical coherence tomography (OCT) system to investigate the effects of stabilization on acquisition of high-resolution retinal sections. The prototype retinal tracker locks onto common fundus features, detects transverse eye motion via changes in feature reflectance, and positions the OCT diagnostic beam to fixed coordinates on the retina with mirrors driven by a feedback control loop. The system is tested in a full clinical protocol on subjects with normal and glaucomatous eyes. Experimental analysis software is developed to coalign and coadd multiple fundus and OCT images and to extract quantitative information on the location of structures in the images. Tracking is highly accurate and reproducible on all but one subject, resulting in the ability to scan the same retinal location continually over long periods of time. The results show qualitative improvement in 97% of coadded OCT scans and a reduction in the variance of the position of the optic disc cup edge to less than 1 pixel (<60 μm). The tracking system can be easily configured for use in research on ultra-high-resolution OCT systems for advanced image modalities. For example, tracking will enable very high density 3-D scans of the retina, which are susceptible to eye motion artifacts even for new high-speed systems. © 2005 Society of Photo-Optical Instrumentation Engineers.

Figures in this Article
© 2005 Society of Photo-Optical Instrumentation Engineers

Citation

Lelia Adelina Paunescu ; Daniel X. Hammer ; R. Daniel Ferguson ; Siobahn Beaton ; Hiroshi Ishikawa, et al.
"Active retinal tracker for clinical optical coherence tomography systems", J. Biomed. Opt. 10(2), 024038 (Dec. 18, 2003May 25, 2004Sep. 9, 2004Apr. 13, 2005April 13, 2005). ; http://dx.doi.org/10.1117/1.1896967


Access This Article
Sign In to Access Full Content
Please Wait... Processing your request... Please Wait.
Sign in or Create a personal account to Buy this article ($20 for members, $25 for non-members).
 
Your Session has timed out. Please sign back in to continue.
Sign In to Access Full Content

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging & repositioning the boxes below.

Related Book Chapters

Topic Collections

Advertisement

Buy this article ($18 for members, $25 for non-members).
Sign In