Direct measurement of the evanescent field profile produced by objective-based total internal reflection fluorescence

[+] Author Affiliations
Alexa L. Mattheyses

University of Michigan, Biophysics Research Division, Ann Arbor, Michigan 48109

Daniel Axelrod

University of Michigan, Biophysics Research Division, and Department of Physics, Ann Arbor, Michigan 48109

J. Biomed. Opt. 11(1), 014006 (January 24, 2006). doi:10.1117/1.2161018
History: Received January 28, 2005; Revised August 08, 2005; Accepted August 29, 2005; Published January 24, 2006
Text Size: A A A

Total internal reflection fluorescence (TIRF) microscopy produces a thin excitation field (the evanescent field) that nominally decays exponentially. This field is ideal for selective excitation of fluorophores near the coverslip/sample interface. We present an experimental method, where the depth and axial profile of the evanescent field can be measured directly by microscopic observation of low refractive index fluorescently labeled spherical beads in an index-matched solution. To demonstrate the technique, through-the-objective TIRF is set up with laser excitation. In this configuration, the axial profile of the evanescent field created by either a 1.45-numerical aperture (NA) or a 1.65-NA objective fits well to a double exponential. At the coverslip/sample interface, about 90% of the evanescent field is represented by an exponential with a decay rate consistent with that expected for a theoretical evanescent field; the remaining 10% of the field is represented by an exponential with a much longer decay constant and is identified as scattering. The approach presented here is particularly useful for investigating the quality and axial profile of the evanescent field in both laser-based and mercury arc-based through-the-objective TIRF systems where a significant amount of light scattering can occur in the illumination optics.

Figures in this Article
© 2006 Society of Photo-Optical Instrumentation Engineers

Citation

Alexa L. Mattheyses and Daniel Axelrod
"Direct measurement of the evanescent field profile produced by objective-based total internal reflection fluorescence", J. Biomed. Opt. 11(1), 014006 (January 24, 2006). ; http://dx.doi.org/10.1117/1.2161018


Access This Article
Sign In to Access Full Content
Please Wait... Processing your request... Please Wait.
Sign in or Create a personal account to Buy this article ($20 for members, $25 for non-members).
 
Your Session has timed out. Please sign back in to continue.
Sign In to Access Full Content

Tables

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging & repositioning the boxes below.

Related Book Chapters

Topic Collections

PubMed Articles
Advertisement

Buy this article ($18 for members, $25 for non-members).
Sign In