Errata

Errata: Two-photon microscope for multisite microphotolysis of caged neurotransmitters in acute brain slices

[+] Author Affiliations
Bradley E. Losavio

Baylor College of Medicine, Department of Neuroscience, One Baylor Plaza, Houston, Texas 77030

Vijay Iyer

Howard Hughes Medical Institute, 19700 Helix Drive, Ashburn, Virginia 20147

Peter Saggau

Baylor College of Medicine, Department of Neuroscience, and Department of Molecular Physiology and Biophysics, One Baylor Plaza, Houston, Texas 77030

J. Biomed. Opt. 15(1), 019801 (February 24, 2010). doi:10.1117/1.3311562
History: Published February 24, 2010; Online February 24, 2010
Text Size: A A A

Open Access Open Access

This article [J. Biomed. Opt.14, 064033 (2009)] was originally published online on 31 December 2009 with errors in Table 1. The following corrections were made:

  1. In column 2, row 2, the first numeral 2 underneath the square root bracket was removed;
  2. In column 2, row 4, θcompensated was changed to θdispersion. Also “gratting” was changed to “grating.”
  3. In column 4, row 6, the value “627” was changed to “672.” The corrected table appears below.

In addition, in the line following Eq. (11) on page 8, the first super script −7 was corrected to −5 to read “with the parameters λ=7.2×105 cm, c=3×105 cm/fsec”. All versions of the article were corrected on 12 January 2010 and the article appears correctly in print.

Table Grahic Jump Location
Theoretical spectral dispersion and compensation of TeO2 AODs. The following parameters are used: wavelength λ=720 nm; spectral bandwidth Δλ=3.68 nm; AOD aperture D=10 nm; acoustic velocity v=676 m/sec; scan range θscan=42.6 mrad; diffraction θdiffraction=0.0634 mrad; grating pitch d=150 grooves/mm; effective compensation frequency fcomp=vd2=71.1 MHz; and compensation θgrating=2Δλfcomp/v=552 μrad.
Table Footer NoteWhen θcompensated<θdiffraction , the number of compensated spots becomes N=θscan/θdiffraction, and the scanning is diffraction limited.

Citation

Bradley E. Losavio ; Vijay Iyer and Peter Saggau
"Errata: Two-photon microscope for multisite microphotolysis of caged neurotransmitters in acute brain slices", J. Biomed. Opt. 15(1), 019801 (February 24, 2010). ; http://dx.doi.org/10.1117/1.3311562


Figures

Tables

Table Grahic Jump Location
Theoretical spectral dispersion and compensation of TeO2 AODs. The following parameters are used: wavelength λ=720 nm; spectral bandwidth Δλ=3.68 nm; AOD aperture D=10 nm; acoustic velocity v=676 m/sec; scan range θscan=42.6 mrad; diffraction θdiffraction=0.0634 mrad; grating pitch d=150 grooves/mm; effective compensation frequency fcomp=vd2=71.1 MHz; and compensation θgrating=2Δλfcomp/v=552 μrad.
Table Footer NoteWhen θcompensated<θdiffraction , the number of compensated spots becomes N=θscan/θdiffraction, and the scanning is diffraction limited.

References

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging & repositioning the boxes below.

Related Book Chapters

Topic Collections

PubMed Articles
Advertisement


 

  • Don't have an account?
  • Subscribe to the SPIE Digital Library
  • Create a FREE account to sign up for Digital Library content alerts and gain access to institutional subscriptions remotely.
Access This Article
Sign in or Create a personal account to Buy this article ($20 for members, $25 for non-members).
Access This Proceeding
Sign in or Create a personal account to Buy this article ($15 for members, $18 for non-members).
Access This Chapter

Access to SPIE eBooks is limited to subscribing institutions and is not available as part of a personal subscription. Print or electronic versions of individual SPIE books may be purchased via SPIE.org.