|
1.IntroductionOptical fiber refractometers are widely employed in chemical and biological applications, owing to advantages such as easy fabrication, low cost, high sensitivity, safety in hazardous environments, and immunity to electromagnetic interference. Many fiber refractometers have been presented, for example, a fiber Bragg grating based refractometer,1 a fiber Fabry-Perot structure,2, 3 a refractometer based on long period grating,4, 5 an abrupt taper Michelson interference-based refractometer,6 and a single-mode/multimode/single-mode fiber structure refractometer.7, 8 Recently, a refractometer based on a large-mode-area photonic crystal fiber (PCF) (LMA-8) was also demonstrated, and the corresponding measurement resolution of the 32-mm-long interferometer was about 2.9×10−4 refractive index units (RIUs) in the refractive index range of 1.38 to 1.44.9 A reflective modal interferometer based on a 22-mm solid-core photonic crystal fiber (SC-PCF) was also proposed and used for refractive index measurement10 and volatile organic compound (VOC) detection.11 Recently, hollow-core photonic crystal fiber (HC-PCF)-based modal interference has been investigated for potential in sensing applications. A modal interferometer based on a 27.8-cm-long HC-PCF has been presented,12 employing strain and temperature measurements. The interference fringe still appeared, even when using a butt-coupling method instead of fusion splicing. The characteristic of HC-PCF was unique13 and different from SC-PCF-based modal interferometers, which were built by some special coupling methods.14 In this work, a miniature refractometer based on modal interference in the HC-PCF is demonstrated. A special splicing method is used to produce complete collapse of air holes in the core and cladding of the HC-PCF. Due to the complete collapse effect, this proposed interferometer is highly sensitive to the change of refractive index outside the fiber. The sensor fabrication and principle are described. Results and discussion are presented, and a conclusion is given. 2.Sensor Fabrication and PrincipleThe 1.2-mm HC-PCF-based modal interferometer was fabricated by splicing the two ends of a HC-PCF (HC-1550-02, Crystal Fiber A/S, NKT Photonics, Birkerød, Denmark) to a single-mode fiber (SMF). The core diameter of a HC-PCF is about 10.9 μm with a pitch of 3.8 μm, with a larger than 90% air filling fraction. The coating of the HC-PCF was stripped before splicing. The fiber end of the HC-PCF was cleaved by a CT-30 cleaver (Fujikura, Fairfield, Connecticut), and spliced to the SMF with a manual operation program described in Ref. 15. Then another fiber end of the HC-PCF was cleaved with fiber length control, and the total length of the HC-PCF was about 1.2 mm. The next procedure was the splicing for the second point under the same program. Fusion splicing was performed by using a Sumitomo Type-36 splicer (Sumitomo Electric Lightwave, Research Triangle Park, North Carolina), and the parameter settings for fusion splicing were the default parameters for the splicing of two standard SMFs. The insertion loss of the fabricated sensor was about 30 dB; it is very high because of air hole collapse and power leakage. The air holes of the HC-PCF were completely collapsed and the length of each collapsed region was about 300 μm, as shown in Fig. 1. Air hole collapse can be verified by using a microscope to observe the fiber end. After complete collapse, the HC-PCF becomes a stub of glass, and the outer diameter of the HC-PCF is less than that of the SMF. Figure 2 shows the experimental setup and the structure of the 1.2-mm HC-PCF-based interferometer for refractive index measurement. The length of the sensing section was about 600 μm with the exception of the spliced area. The light from the broadband light source was passed through the SMF to the HC-PCF. The light transmitted from the HC-PCF entered into an optical spectrum analyzer (OSA, AQ6370, Yokogawa Company, Limited, Tokyo, Japan), and the corresponding transmission spectrum was acquired by the OSA. The broadband light source was an amplified spontaneous emission (ASE), which has a wavelength range of 1520 to 1600 nm. When the light passed through the input SMF and entered into the collapsed region (part A in Fig. 2) of the HC-PCF, the fundamental core mode spread widely, and then the higher-order cladding modes were excited inside the HC-PCF. After the propagation of these modes inside the HC-PCF, they recombined at the second collapsed region (part B in Fig. 2) and propagated in the output SMF. Therefore, the modal interference was formed as described in Refs. 12 and 13. The transmission of the modal interferometer is expressed by the interference of two dominated modes,9 Eq. 1[TeX:] \documentclass[12pt]{minimal}\begin{document}\begin{equation} T = I_{co} (\lambda) + I_{cl} (\lambda) + 2[I_{co} (\lambda)I_{cl} (\lambda)]^{1/2} \cos (2\pi \Delta n_{{\rm eff}} L/\lambda), \end{equation}\end{document}3.Results and DiscussionThe refractive index liquid samples (Cargille Laboratories, Cedar Grove, New Jersey), which have refractive indices of 1.35, 1.37, 1.39, 1.41, and 1.43, were used for the refractive index measurement of the HC-PCF-based refractometer. The calibrated refractive index accuracy for each liquid was ±0.0002 refractive index units (RIUs). Figure 3 shows the transmission spectra of a HC-PCF-based interferometer with different refractive indices outside the HC-PCF at room temperature. It appears that the interference fringes with good visibility and the maximum extinction ratio is about 7 dB. The wavelength separation between the adjacent peaks or dips is about 20 nm. When the refractive index was varied from 1.35 to 1.43, the dip wavelength shifted from 1593.28 to 1596.16 nm, corresponding a total red shift of 2.88 nm, as shown in Fig. 4. The red shift is observed because the increase of the refractive index leads to the increase of Δn eff. The wavelength shift of the interference fringe becomes larger with the increase of the refractive index, so the sensitivity for the range of 1.39 to 1.43 is higher than that for the range of 1.35 to 1.39, which is similar to the SC-PCF-based refractometer.9 The sensitivities of 24.5 and 46.5 nm / RIU for the index range of 1.35 to 1.39 and 1.39 to 1.43 are achieved, respectively. Thus, the resolutions of refractive index measurement for the range of 1.35 to 1.39 and 1.39 to 1.43 are about 8.1×10−4 and 4.3×10−4 RIUs, respectively, considering a wavelength resolution of 20 pm of the OSA used in the experiment, which is comparable to other refractometers. 1, 2, 4, 5, 6,, 9, 10, 11, In addition, the lengths of the sensing fibers of the other refractometers, such as single-mode/multimode/single-mode-based refractometers 7, 8, and SC-PCF modal interference-based refractometers, 9, 10, 11, are approximately dozens of millimeters, while that of the HC-PCF modal interference-based refractometer is just about 600 μm. The small-sized refractometer has an adventage in chemical and biological applications, because it needs only one microliter samples. Figure 5 shows the wavelength shift of the dip with the increase of external temperature. The peaks or dips in the transmission spectrum are shifted because the effective indices of these modes are dependent on the temperature effect, and the thermal expansion leads to variation of fiber length. When the temperature was increased from 25 to 75°C, the wavelength of the dip in the transmission was changed from 1593.84 to 1594.92 nm, corresponding to a red shift of about 1.08 nm. The wavelength shift of the dip has a linear relationship with the temperature change, and a sensitivity of about 22 pm/°C is achieved, as shown in Fig. 6. The temperature variation can affect the resolution of the refractive index measurement. The corresponding refractive index measurement error due to the temperature effect is about 8.9×10−4 RIU/°C. However, our experiments were conducted in a temperature-controlled environment; the corresponding temperature variation was about 0.2°C, so the refractive index measurement error by the effect of temperature was about 1.8×10−4 RIU, which is less than that limited by the wavelength resolution of the OSA. Therefore, our experimental results of refractive index measurement are reliable, and the temperature effect can be ignored if the temperature variation is less than 1°C. 4.ConclusionsA 1.2-mm HC-PCF-based miniature modal interferometer for refractive index measurement is demonstrated. The complete collapse of air holes in the HC-PCF introduces a high sensitivity to refractive index change outside the HC-PCF. The resolutions of refractive index measurement for the ranges of 1.35 to 1.39 and 1.39 to 1.43 are about 8.1×10−4 RIU and 4.3×10−4 RIUs, respectively. The index measurement error due to the temperature effect is about 8.9×10−4 RIU/°C. Therefore, the temperature effect could be ignored if the temperature variation is less than 1°C. Moreover, the proposed miniature refrectometer has advantages such as reuse, small size, robustness, easy fabrication, and an all-fiber and all-sealed structure, so it is very suitable for chemical and biological applications. AcknowledgmentThis work was supported by the Network Technology Research Center, School of Electrical and Electronic Engineering, Nanyang Technological University, and also supported by the China 973 program (grant number 2010CB327804). ReferencesW. Liang, Y. Huang, Y. Xu, R. K. Lee, and
A. Yariv,
“Highly sensitive fiber Bragg grating refractive index sensors,”
Appl. Phys. Lett., 86
(15), 151122
(2005). https://doi.org/10.1063/1.1904716 Google Scholar
O. Frazão, P. Caldas, J. L. Santos, P. V. S. Marques, C. Turck, D. J. Lougnot, and
O. Soppera,
“Fabry-Perot refractometer based on an end-of-fiber polymer tip,”
Opt. Lett., 34
(16), 2474
–2476
(2009). https://doi.org/10.1364/OL.34.002474 Google Scholar
M. Deng, C. P Tang, T. Zhu, Y. J. Rao, L. C. Xu, and
M. Han,
“Refractive index measurement using photonic crystal fiber-based Fabry–Perot interferometer,”
Appl. Opt., 49
(9), 1593
–1598
(2010). https://doi.org/10.1364/AO.49.001593 Google Scholar
L. Mosquera, D. Sáez-Rodriguez, J. L. Cruz, and
M. V. Andrés,
“In-fiber Fabry- Perot refractometer assisted by a long-period grating,”
Opt. Lett., 35
(4), 613
–615
(2010). https://doi.org/10.1364/OL.35.000613 Google Scholar
J. F. Ding, A. P. Zhang, L. Y. Shao, J. H. Yan, and
S. He,
“Fiber-taper seeded long-period grating pair as a highly sensitive refractive-index sensor,”
IEEE Photon. Technol. Lett., 17
(6), 1247
–1249
(2005). https://doi.org/10.1109/LPT.2005.847437 Google Scholar
Z. Tian, S. S. H. Yam, and
H-P. Loock,
“Refractive index sensor based on an abrupt taper Michelson interferometer in a single-mode fiber,”
Opt. Lett., 33
(10), 1105
–1107
(2008). https://doi.org/10.1364/OL.33.001105 Google Scholar
Q. Wang and
G. Farrell,
“All-fiber multimode-interference based refractometer sensor: proposal and design,”
Opt. Lett., 31
(3), 317
–319
(2006). https://doi.org/10.1364/OL.31.000317 Google Scholar
J. Villatoro and
D. Monzón-Hernández,
“Low-cost optical fiber refractive-index sensor based on core diameter mismatch,”
J. Lightwave Technol., 24
(3), 1409
–1413
(2006). https://doi.org/10.1109/JLT.2005.863246 Google Scholar
R. Jha, J. Villatoro, G. Badenes, and
V. Pruneri,
“Refractometry based on a photonic crystal fiber interferometer,”
Opt. Lett., 34
(5), 617
–619
(2009). https://doi.org/10.1364/OL.34.000617 Google Scholar
R. Jha, J. Villatoro, and
G. Badenes,
“Ultrastable in reflection photonic crystal fiber modal interferometer for accurate refractive index sensing,”
Appl. Phys. Lett., 93
(19), 191106
(2008). https://doi.org/10.1063/1.3025576 Google Scholar
J. Villatoro, M. P. Kreuzer, and
R. Jha,
“Photonic crystal fiber interferometer for chemical vapor detection with high sensitivity,”
Opt. Express, 17
(3), 1447
–1453
(2009). https://doi.org/10.1364/OE.17.001447 Google Scholar
S. H. Aref, R. Amezcua-Correa, J. P. Carvalho, O. Frazão, P. Caldas, J. L. Santos, F. M. Araújo, H. Latifi, F. Farahi, L. A. Ferreira, and
J. C. Knight,
“Modal interferometer based on hollow-core photonic crystal fiber for strain and temperature measurement,”
Opt. Express, 19
(21), 18669
–18675
(2009). https://doi.org/10.1364/OE.17.018669 Google Scholar
R. Amezcua-Correa, F. Gèrôme, S. G. Leon-Saval, N. G. R. Broderick, T. A. Birks, and
J. C. Knight,
“Control of surface modes in low loss hollow-core photonic bandgap fibers,”
Opt. Express, 16
(2), 1142
–1149
(2008). https://doi.org/10.1364/OE.16.001142 Google Scholar
J. Villatoro, V. Finazzi, G. Badenes, and
V. Pruneri,
“Highly sensitive sensors based on photonic crystal fiber modal interferometers,”
J. Sensors, 2009 747803
(2009). Google Scholar
Y. Wang, H. Bartelt, S. Brueckner, J. Kobelke, M. Rothhardt, K. Mörl, W. Ecke, and
R. Willsch,
“Splicing Ge-doped photonic crystal fibers using commercial fusion splicer with default discharge parameters,”
Opt. Express, 16
(10), 7258
–7263
(2008). https://doi.org/10.1364/OE.16.007258 Google Scholar
|