1 February 2011 Stent-induced coronary artery stenosis characterized by multimodal nonlinear optical microscopy
Han-Wei Wang, Ji-Xin Cheng, Michael Sturek, Vlad V. Simianu, Matthew J. Locker
Author Affiliations +
Abstract
We demonstrate for the first time the applicability of multimodal nonlinear optical (NLO) microscopy to the interrogation of stented coronary arteries under different diet and stent deployment conditions. Bare metal stents and Taxus drug-eluting stents (DES) were placed in coronary arteries of Ossabaw pigs of control and atherogenic diet groups. Multimodal NLO imaging was performed to inspect changes in arterial structures and compositions after stenting. Sum frequency generation, one of the multimodalities, was used for the quantitative analysis of collagen content in the peristent and in-stent artery segments of both pig groups. Atherogenic diet increased lipid and collagen in peristent segments. In-stent segments showed decreased collagen expression in neointima compared to media. Deployment of DES in atheromatous arteries inhibited collagen expression in the arterial media.

1.

Introduction

Regarded as an iatrogenic disease, in-stent restenosis is a complex response after coronary stenting1 and still remains a clinical problem. 2, 3 Although stenting very effectively recovers lumen size acutely, there is restenosis and, despite impressive attenuation of restenosis by drug-eluting stents (DESs), long-term anticoagulation therapy is required to decrease the risk of thrombosis. 1, 3, 4 Factors in the restenosis occurrence, also known as neointimal hyperplasia, have been debatable topics for decades. 5, 6, 7 Molecular expression, vessel size, stent type, eluting drug coating, stenting methods, etc., may all affect neointimal hyperplasia. 5, 6 It is widely accepted that smooth muscle cells are involved in neointimal hyperplasia. The inflammatory response, proliferation, and migration of smooth muscle cells, and thus its responses of extracellular matrix formation highly contribute to the process of restenosis through cellular and molecular pathophysiological pathways. 4, 7 Therefore, the major efforts to reduce restenosis have been placed on inhibiting the activation and migration of smooth muscle cells. 8, 9 Accumulation of extracellular matrices that contribute highly to in-stent restenosis has also been highlighted. 10, 11 To evaluate stent efficacy and composition of the vascular wall in restenosis, imaging techniques have been taking on key roles. Beyond histological evaluations that have been established as the gold standard for biopsy inspections, magnetic resonance imaging and computed tomography have been demonstrated to identify luminal narrowing after stent placement. 12, 13 Angiography and intravascular ultrasound have also been used not only to optimize the guidance of stent implantation, 14, 15 but also to quantify severity of restenosis.16 Although intravascular ultrasound can provide some identification of arterial wall composition,12 only histological staining provides cellular details and compositional specificity.

There has been an increasing focus in the past decade on using nonlinear optical (NLO) microscopy17 for imaging biological tissues because of its unique advantages, such as inherent 3-D resolution and near-infrared (NIR) excitation for superior optical penetration.18 Notably, by utilizing intrinsic sources of NLO signals, NLO imaging has been used intensively for studies of unstained tissues. 19, 20, 21, 22, 23, 24, 25, 26, 27 For vascular studies, elastin and collagen fibrils can be visualized without labeling by two-photon excitation fluorescence (TPEF) and second harmonic generation (SHG) microscopies, respectively. 22, 28 Recently, an integration of multiple NLO modalities has been used for the identification of vasculature and arterial cells.29 Sum frequency generation (SFG)30 was used for the visualization of arterial collagen matrices. The SFG that derives its signal from noncentrosymmetric molecules at the sum frequency of two excitation sources showed imaging capability similar to that of SHG for biological tissues.25 Beyond endogenous sources of NLO signals, two-photon microscopy gave remarkable results in imaging arterial cells with the aid of labels. 31, 32 For atherosclerosis studies, NLO microscopy has also been demonstrated to provide insightful information. 33, 34, 35, 36, 37 Le applied coherent anti-stokes Raman scattering (CARS) microscopy to visualize lipid-laden cells in atheroma.33 Lilledahl recently utilized SHG and TPEF imaging to identify the fibrous cap of vulnerable plaques.34 Our recent work further utilized a CARS-based NLO microscopy for characterizing different atherosclerotic stages from early to advanced lesions.35 Regarding restenosis, however, it is still unknown whether NLO microscopy can provide morphometric and quantitative analysis. The modalities of NLO microscopy hold great promise to be useful in the characterization of restenotic arteries, which may assist in the design and improvement of stent therapy. To address these needs, in the present study we demonstrate for the first time the applicability of multimodal NLO microscopy to the interrogation of stented coronary arteries. The label-free imaging allowed visualization of the degree of in-stent stenosis and, more importantly, cellular and extracellular matrix composition. Quantitative analyses of collagen deposition in stented arteries were performed using the SFG signal. The results revealed the effects of the diet and DES placement on the collagen expression in coronary arteries of a clinically relevant porcine model.

2.

Experimental Methods

2.1.

Experimental Design

The experimental procedures and protocols were approved by an Institutional Animal Care and Use Committee and complied fully with Ref. 38. Ossabaw miniature pigs (N = 10) were placed on diets for 22–24 weeks before stenting. Lean Ossabaw control pigs (N = 5) were fed with a normal maintenance diet, which contained 8% kcal from fat, 22% kcal from protein, 70% kcal from carbohydrates. Obese, metabolic syndrome (MetS) pigs (N = 5) were fed a high-fat/high-cholesterol, atherogenic diet, which was composed of 2% cholesterol, 20% kcal from fructose, and 46% kcal from hydrogenated soybean oil that is high in trans fatty acids.39 The genetic predisposition of Ossabaw pigs to obesity and metabolic syndrome promotes the development of cardiovascular disease 15, 16 and greater in-stent neointimal hyperplasia compared with other leaner breeds, such as Yucatan and domestic. 15, 16, 40

Procedures of surgery and stent deployment can be found elsewhere. 11, 16, 41 Three stents were deployed in the distal circumflex (CFX) and left anterior descending (LAD) coronary arteries of each pig in both groups [Fig. 1a]. Three stent deployments were bare metal stent (BMS) with 1.0× expansion, relative to the normal lumen diameter and Taxus stent (Boston Scientific, Inc., Natick, MA.) with 1.0× and 1.3× expansion ratios. 15, 16, 40 The Taxus stent is a paclitaxel-coated DES. Before stent placement, intravascular ultrasound and angiographic imaging were used to measure the lumen diameter.

Fig. 1

Schematic of coronary stent deployment and sample collection. (a) Schematic drawing of coronary arteries and the study design. (b) Collected arterial sections included peristent and in-stent segments. (c) Subsegments collected for NLO imaging and histology. The right coronary (RC) artery had no stents deployed in it (nonstented).

021110_1_1.jpg

Coronary arteries from these two groups were harvested after four weeks of recovery from stent placement.15 A sternotomy was performed to excise the heart into cold saline. Coronary artery segments were then collected. Segments covered peristent and in-stent locations of the three kinds of stent deployments [Fig. 1b]. Peristent segments were derived 2–5 mm proximal and distal to the stent. Right coronary arteries, where no stents was deployed, were also collected as a control representing the natural course of healthy or atherosclerotic coronary arteries. Each segment collected was sectioned into subsegments for NLO microscopy and histology [Fig. 1c]. Collected arterial segments were encoded for blind imaging and analysis. Arteries were preserved by zinc formalin solution after harvest and washed with phosphate buffered saline before NLO imaging.

2.2.

Multimodal Nonlinear Optical Microscopy

Details of our multimodal imaging setup can be found elsewhere.29 Briefly, two synchronized 5-ps lasers (Tsunami, Spectra-Physics, Irvine, CA.) operating at an 80-MHz repetition rate were parallel-polarized, collinearly combined, and directed into a laser-scanning microscope (FV300/IX71, Olympus, Center Valley, PA.). A 20× air objective with a numerical aperture (NA) of 0.75 and a 60× water immersion objective with a 1.2 NA were used for the NLO imaging. Mosaic images were stitched manually with subimages taken by the 20× objective. Subimages were highly overlapped with each other at ∼75% of the imaging area of a 353 × 353 μm2 field of view. Signals were detected by external photomultiplier tubes (H7422-40, Hamamatsu, Bridgewater, NJ.).

For CARS imaging,42 the frequency difference of the two NIR lasers was tuned to 2840 cm−1, which matches the symmetric CH2 stretch vibration. 42, 43 Bandpass filters (600/65 nm, Ealing Catalog, Rocklin, CA.) were used to transmit the CARS signal of ∼588 nm. The average powers of the pump and the Stokes laser beams at the sample were 40 and 20 mW, respectively. The same lasers were used to generate the SFG signal at ∼393 nm. Two bandpass filters (HQ375/50m-2p, Chroma, Bellows Falls, VT.) were used for the collection of the backward SFG signal. For TPEF imaging of unlabeled samples, two bandpass filters (hp520/40m-2p, Chroma) were used to transmit autofluorescence. For TPEF imaging of arterial cell nuclei labeled by Doxorubicin, two 600/65-nm filters were used. The TPEF signal was generated by only using the pump laser (∼707 nm) to avoid the CARS signal at ∼588 nm.

2.3.

Histological Imaging

The arterial segments for the comparison to histology were routinely processed with paraffin embedding and then sectioned for staining. Hematoxylin and eosin was used for the identification of general cell morphology, including the lipid-rich cells that give bubbly and granular appearances. Masson's trichrome was used to identify collagen. Images were captured with a Nikon CoolPix 990 digital camera on a Nikon Diaphot inverted microscope (Nikon, Melville, NY).

2.4.

Quantitative Analysis

Collagen content was quantitatively assessed by SFG and histology images. Serial sections of arterial samples were used for a correlation study between SFG and histological evaluations. Measurements were performed with Image Pro Plus v.4.1 (Media Cybernetics, Bethesda, MD.). For histology images, collagen content in tunica media and in adventitia of an artery was determined according to Masson's trichrome staining. The measurement was made by colorimetric analysis with the adventitia as a reference color template. Pixels presented the color of collagen stain were retrieved from the 24-bit, full-color images, and then the area percentage was derived as compared to the total pixels in the area selected. For SFG images, collagen content was measured according to the SFG signal. Area percentage of collagen was derived according to the percentage of pixels that gave a positive signal over a threshold. Background threshold, color code, and color scale were set identically for the routine analyses. Each data point in the correlation graph is an average value of 12 rectangular, (50 × 50)-μm2, areas in an arterial stratification along the arterial ring. The same analysis routines were then applied to the study of SFG quantitation of collagen content.32

2.5.

Statistical Analysis

Results are presented as mean ±SD (p < 0.01). The paired student t-test was used to identify the statistical differences among means in the correlation study of collagen analysis between SFG and histology imaging. One-way analysis of variance (ANOVA) with a posthoc testing (Tukey's test) was performed to identify the statistical differences among groups. The threshold for statistical significance was p = 0.05.

3.

Results

Coronary arteries deployed with the 1.0× BMS, 1.0× Taxus, and 1.3× Taxus (Table 1) were interrogated by the multimodal NLO microscopy. Adjacent arterial sections were histologically stained to verify the integrity of the NLO imaging. For peristent samples, 10 arterial sections from the control group and 13 from the metabolic syndrome group were imaged. Figure 2 shows representative images of arterial structures visualized in peristent samples from both groups. Typically, peristent samples from the control group showed normal arterial vasculature [Figs. 2a, 2b, 2c] and gave no observable difference from the structures in right coronary control samples. Organized lamellae of elastin and collagen were clearly identified in tunica media. By contrast, atheroma [Figs. 2d, 2e, 2f], characterized by scattered lipid accumulations [Figs. 2g and 2h] and a thickened intima [Figs. 2d, 2e, 2f, 2i], was frequently observed in the peristent coronary arteries of the MetS group. In general, arterial structures and lesions were well protected at the peristent locations from the mechanical disturbance of stent deployment.

Fig. 2

(Color online only.) NLO images of peristent arteries showed typical normal and atherosclerotic composition. (a–c) are mosaic images of CARS (lipid, cell structure), SFG (collagen), and TPEF (elastin), respectively, of a peristent coronary artery segment from the control group. Normal arterial structure was preserved at the peristent segment of a 1.0× BMS deployment. Adventitia (Adv) shows typically abundance of collagen (blue) and elastin (green), while the media (Med) has little collagen and elastin. The internal elastic (IE) lamina is distinct in healthy arteries. Each mosaic image contains 35 subimages. (d–f) are images of an early stage atheroma observed by CARS, SFG, and TPEF, respectively, in a peristent sample in the atherogenic diet MetS group. The mosaic images, formed with 36 subimages, at the peristent location show characteristics of an early stage atheroma that included a scattered lipid accumulation, higher collagen expression, and disorganized elastic lamellae in thickened intima and adjacent media. (g) A colocalized image of three NLO modalities at the red box in (c) shows the scattered lipid deposits (white) in the thickened intima with interlacing of collagen and elastin. (h) Zoomed-in image at the yellow box in (d) shows the pathologic infiltration of lipid-rich cells and corresponding collagen matrices. (i) Histological imaging of Masson's trichrome at corresponding segment showing collagen (blue) and cellular material in the media (red), while a predominance of collagen in the adventitia. L: Lumen. CARS: gray, SFG: blue, TPEF: green. The same color code is used in other images.

021110_1_2.jpg

Table 1

In-stent and peristent arterial specimens of different stent deployments in different diet groups.

ControlMetS
PeristentIn-stentVesselPeristentIn-stentVessel
BMS 1.045LAD45LAD
DES 1.024CFX45CFX
DES 1.344CFX55CFX

1.0 and 1.3: Fold expansion of stent relative to normal lumen diameter.

To interrogate in-stent arterial segments, a total sample number of 13 of the three deployment conditions in the control group and 15 of those in the high-fat group were imaged. Figure 3 exemplifies the arterial composition in a 1.0 Taxus deployed coronary artery of the MetS group. Locations of stent struts identified in CARS and SFG images [Figs. 3a and 3b] allowed circumscribing the area of in-stent neointimal hyperplasia. In-stent artery segments can thus be identified due to the cellular contrast in the CARS images. Around the strut locations, the edges close to the arterial wall showed higher CARS and SFG signals [Figs. 3c and 3d], thus implying a lipid accumulation and abundant collagen deposition. Higher lipid content at these locations is likely due to the compression of the stents to the prestent lipid accumulation at the lumen area. A higher collagen signal at the edges of the stent strut could result from the compressed collagen layers and possibly the activation of collagen synthesis along with the mechanical pressure exerted by the stents.44 In addition, atrophy of media [Figs. 3a, 3b] was a typical occurrence at the strut locations.

Fig. 3

Atrophy in media and low collagen expression in stenotic tissue are typical in arteries with 1.0x Taxus stents. The mosaic image of CARS in (a) shows the locations of struts (arrows) and the stenotic tissue (neointimal hyperplasia) under it. The SFG image in (b) detects the distribution of collagen in the stented arteries without labels and shows low collagen in the media and neointima. (c,d) are zoomed-in images of CARS and SFG, respectively, at the box in (a). Strong CARS and SFG signals were observed above the strut location. Straightened collagen fibrils were observed along the strut locations. Neo: neointimal hyperplasia.

021110_1_3.jpg

Compared to 1.0-Taxus-deployed coronaries, images of 1.3-Taxus-deployed coronaries showed greater atrophy at strut locations. Figure 4 shows a representative image of a coronary artery deployed with a 1.3 Taxus. The absence of arterial layers above strut locations [Figs. 4a and 4b] shows further damage of the arterial wall, most likely attributed to the overexpansion of the stent. Moreover, NLO imaging gave clear images of stenotic arteries due to the subcellular imaging resolution and showed a predominantly cellular composition [Figs. 4c and 4d]. Stellate-shaped cells were observed in the stenotic arteries by the CARS imaging. Collagen content in the stenoses (neointima), however, was lower than that in the arterial wall peripheral to the stent.

Fig. 4

Representative images of a 1.3× Taxus stent. Minimal media was observed in (a) CARS and (b) SFG images. (c) CARS image taken at the rectangle in (a) shows the proliferating stellate-shaped cells in the stenotic tissue. (d) Cell nuclei were confirmed by doxorubicin (Dox.) labeling.

021110_1_4.jpg

For the analysis of the collagen expression in the stented coronaries, SFG images of the stented coronaries were quantitatively analyzed (Fig. 5). The correlation study shows that the SFG signal gives a valid collagen quantity by comparison to the morphometric results of histological staining [Fig. 5a]. Comparing the collagen expression in the media between the stented and peristent samples of BMS-deployed arteries in the control group, there was no significant difference observed [Fig. 5b]. The result shows that the deployment of the stent at normal lumen diameter did not promote collagen expression in the media. In contrast, the atherogenic diet MetS group showed a trend for higher collagen content in the media [Fig. 5b], but a significant difference was not found using one-way ANOVA with the posthoc testing. The trend for higher collagen content may imply that the activation of smooth muscle cell synthetic phenotype in the media was enhanced by the atherogenic stimulus. The major result was a lower collagen content in the neointima compared to media, and the result was in keeping with former reports on Ossabaw swine.45 Interestingly, there is a significant difference in the collagen content of stenotic arteries between BMS- and DES-deployed arteries. The collagen content was lower in both neointima and media with the deployment of drug eluting stents [Fig. 5b]. Although there was not a significant difference between the collagen in neointima of the BMS versus DES groups, there was decreased collagen in the media of the DES compared to BMS group.

Fig. 5

Quantitative analysis of collagen according to the SFG signal in stented arteries. (a) Correlation of collagen percentage between the SFG and histological evaluations (R 2 = 0.72). (b) Comparison of collagen percentages among different locations of different groups with different stents. C: control group; MetS: metabolic syndrome group; BMS: Bare metal stent of 1.0 expansion ratio; DES: Taxus drug-eluting stent of 1.0 expansion ratio; Peri: peristent sample; InS: in-stent sample; Med: media; Neo: neointimal hyperplasia. The asterisk and bars indicate the significant differences between specific groups (P < 0.05).

021110_1_5.jpg

4.

Discussion

In the present study, we interrogated in-stent and peristent coronary arterial samples by multimodal NLO microscopy. The major finding is that we have shown with label-free NLO imaging cellular proliferation, lipid accumulation, and extracellular matrix changes in the arterial media and neointima after stent deployment. Quantification of collagen in neointima was correlated with “gold-standard” histological methods. The discrepancy in the analysis of collagen is most likely because of the variation between serial sections used in NLO and histological analyses. Nevertheless, the correlation provided confidence in our finding that, compared to bare metal stents, paclitaxel-eluting stents decrease collagen extracellular matrix production in arterial media and possibly neointima.

Mosaic imaging was carried out to provide a large area of inspection qualitatively and quantitatively. Stellate-shaped cells were visualized in CARS images in the classical neointimal hyperplasia in the stenotic, in-stent artery segments. There was a clear predomination of proliferating smooth muscle cells in the areas. 46, 47, 48 Meanwhile, SFG analysis showed that neointima collagen content was lower than that in the arterial media and even lower in DES-deployed in-stent segments. The result suggested that DES deployment inhibits collagen extracellular matrix production by synthetic phenotype smooth muscle cells, which may allow a great accumulation of fibrin.48 It is known that the increase of extracellular matrix provides the bulk of the in-stent neointimal hyperplasia; 11, 47, 48 therefore, the inhibition of collagen expression by the DES is a major factor in preventing restenosis. Although it is well established that paclitaxel DES inhibits smooth muscle cell proliferation, as well as extracellular matrix formation in vitro and clinically, 47, 48, 49, 50, 51 the influences of the predisposition to neointimal hyperplasia and the drug-release profile could play critical roles. Moreover, the collagen content in the media of DES-deployed arteries is lower than that in the media of BMS-deployed arteries in the MetS group (Fig. 5), thus indicating that drug released from the stent reached the tunica media. 52, 53 Furthermore, the data suggest that DES may inhibit the shift of contractile smooth muscle cells in the media to a synthetic phenotype that predominates in the neointima.

It is notable that instead of stains used in histopathology, cellular characterization was derived by CARS microscopy without labels. Along with the collagen evaluation by SFG imaging, the NLO multimodality provided virtual histology for the identification of cellular structures and collagen fibrils. Additional labels that can be visualized by TPEF modality can further extend the horizons of compositional imaging in vascular pathology. The quantitative analysis in this work demonstrated the applicability of multimodal NLO microscopy to the interrogation of stented coronary arteries. The SFG signal used for quantifying collagen content showed the effects of stent deployment. More extensive application of multimodal NLO, including coherent Raman scattering processes without exogenous labels, to characterize in-stent restenosis and drug effects, may accelerate studies of DES design and selection and therapeutic intervention.

Acknowledgments

This work was supported by a NIH R01 Grant No. EB007243 to J. X. C., NIH Grant Nos. RR013223 and HL062552 to M.S., and the Comparative Medicine Program of Purdue and Indiana University School of Medicine and the Summer Research Program in Academic Medicine program of Indiana University School of Medicine. We thank Dr. Eric A. Mokelke of Boston Scientific, Inc., for the gift of Taxus stents.

References

1. 

N. Kukreja, Y. Onuma, J. Daemen, and P. W. Serruys, “The future of drug-eluting stents,” Pharmacol. Res., 57 (3), 171 –180 (2008). https://doi.org/10.1016/j.phrs.2008.01.012 Google Scholar

2. 

Y. Li, Z. Zheng, B. Xu, S. Zhang, W. Li, R. Gao, and S. Hu, “Comparison of drug-eluting stents and coronary artery bypass surgery for the treatment of multivessel coronary disease: Three-year follow-up results from a single institution,” Circulation, 119 (15), 2040 –2050 (2009). https://doi.org/10.1161/CIRCULATIONAHA.108.819730 Google Scholar

3. 

A. Sourgounis, J. Lipiecki, T. S. Lo, and M. Hamon, “Coronary stents and chronic anticoagulation,” Circulation, 119 (12), 1682 –1688 (2009). https://doi.org/10.1161/CIRCULATIONAHA.108.834861 Google Scholar

4. 

A. K. Mitra and D. K. Agrawal, “In stent restenosis: bane of the stent era,” J. Clin. Pathol., 59 (3), 232 –239 (2006). https://doi.org/10.1136/jcp.2005.025742 Google Scholar

5. 

C. Bauters and J. M. Isner, “The biology of restenosis,” Prog. Cardiovasc. Dis., 40 (2), 107 –116 (1997). https://doi.org/10.1016/S0033-0620(97)80003-5 Google Scholar

6. 

A. Kastrati, A. Dibra, J. Mehilli, S. Mayer, S. Pinieck, J. Pache, J. Dirschinger, and A. Schomig, “Predictive factors of restenosis after coronary implantation of sirolimus- or paclitaxel-eluting stents,” Circulation, 113 (19), 2293 –2300 (2006). https://doi.org/10.1161/CIRCULATIONAHA.105.601823 Google Scholar

7. 

V. Rajagopal and S. G. Rockson, “Coronary restenosis: a review of mechanisms and management,” Am. J. Med., 115 (7), 547 –553 (2003). https://doi.org/10.1016/S0002-9343(03)00477-7 Google Scholar

8. 

M. N. Babapulle and M. J. Eisenberg, “Coated stents for the prevention of restenosis: Part I,” Circulation, 106 (21), 2734 –2740 (2002). https://doi.org/10.1161/01.CIR.0000038982.49640.70 Google Scholar

9. 

D. E. Drachman, E. R. Edelman, P. Seifert, A. R. Groothuis, D. A. Bornstein, K. R. Kamath, M. Palasis, D. Yang, S. H. Nott, and C. Rogers, “Neointimal thickening after stent delivery of paclitaxel: change in composition and arrest of growth over six months,” J. Am. Coll. Cardiol., 36 (7), 2325 –2332 (2000). https://doi.org/10.1016/S0735-1097(00)01020-2 Google Scholar

10. 

D. D. Allison, T. N. Wight, N. J. Ripp, K. R. Braun, and K. J. Grande-Allen, “Endogenous overexpression of hyaluronan synthases within dynamically cultured collagen gels: Implications for vascular and valvular disease,” Biomaterials, 29 (20), 2969 –2976 (2008). https://doi.org/10.1016/j.biomaterials.2008.04.005 Google Scholar

11. 

I.-M. Chung, H. K. Gold, S. M. Schwartz, Y. Ikari, M. A. Reidy, and T. N. Wight, “Enhanced extracellular matrix accumulation in restenosis of coronary arteries after stent deployment,” J. Am. Coll. Cardiol., 40 (12), 2072 –2081 (2002). https://doi.org/10.1016/S0735-1097(02)02598-6 Google Scholar

12. 

D. A. Bluemke, S. Achenbach, M. Budoff, T. C. Gerber, B. Gersh, L. D. Hillis, W. G. Hundley, W. J. Manning, B. F. Printz, M. Stuber, and P. K. Woodard, “Noninvasive coronary artery imaging: Magnetic resonance angiography and multidetector computed tomography angiography: a scientific statement from the american heart association committee on cardiovascular imaging and intervention of the council on cardiovascular radiology and intervention, and the councils on clinical cardiology and cardiovascular disease in the young,” Circulation, 118 (5), 586 –606 (2008). https://doi.org/10.1161/CIRCULATIONAHA.108.189695 Google Scholar

13. 

W. G. Hundley, L. D. Hillis, C. A. Hamilton, R. J. Applegate, D. M. Herrington, G. D. Clarke, G. A. Braden, M. S. Thomas, R. A. Lange, R. M. Peshock, and K. M. Link, “Assessment of coronary arterial restenosis with phase-contrast magnetic resonance imaging measurements of coronary flow reserve,” Circulation, 101 (20), 2375 –2381 (2000). https://doi.org/http://circ.ahajournals.org/cgi/content/abstract/101/20/2375 Google Scholar

14. 

P. Roy, D. H. Steinberg, S. J. Sushinsky, T. Okabe, T. L. P. Slottow, K. Kaneshige, Z. Xue, L. F. Satler, K. M. Kent, W. O. Suddath, A. D. Pichard, N. J. Weissman, J. Lindsay, and R. Waksman, “The potential clinical utility of intravascular ultrasound guidance in patients undergoing percutaneous coronary intervention with drug-eluting stents,” Eur. Heart. J., 29 1851 –1857 (2008). https://doi.org/10.1093/eurheartj/ehn249 Google Scholar

15. 

M. Sturek, M. Alloosh, J. Wenzel, J. P. Byrd, J. M. Edwards, P. G. Lloyd, J. D. Tune, K. L. March, M. A. Miller, E. A. Mokelke, and I. L. Brisbin, “Ossabaw island miniature swine: Cardiometabolic syndrome assessment,” Swine in the Laboratory: Surgery, Anesthesia, Imaging, and Experimental Techniques, CRC Press, Boca Raton (2007). Google Scholar

16. 

J. M. Edwards, M. Alloosh, X. Long, G. M. Dick, P. G. Lloyd, E. A. Mokelke, and M. Sturek, “Adenosine A1 receptors in neointimal hyperplasia and in-stent stenosis in Ossabaw miniature swine,” Coron. Artery Dis., 19 (1), 27 –31 (2008). https://doi.org/10.1097/MCA.0b013e3282f262b4 Google Scholar

17. 

W. R. Zipfel, R. M. Williams, and W. W. Webb, “Nonlinear magic: multiphoton microscopy in the biosciences,” Nat. Biotech., 21 1369 –1377 (2003). https://doi.org/10.1038/nbt899 Google Scholar

18. 

F. Helmchen and W. Denk, “Deep tissue two-photon microscopy,” Nat. Meth., 2 (12), 932 –940 (2005). https://doi.org/10.1038/nmeth818 Google Scholar

19. 

L. Moreaux, O. Sandre, and J. Mertz, “Membrane imaging by second-harmonic generation microscopy,” J. Opt. Soc. Am. B, 17 1685 –1694 (2000). https://doi.org/10.1364/JOSAB.17.001685 Google Scholar

20. 

A. Zoumi, A. Yeh, and B. J. Tromberg, “Imaging cells and extracellular matrix in vivo by using SHG and TPEF,” Proc. Natl. Acad. Sci. USA, 99 11014 –11019 (2002). https://doi.org/10.1073/pnas.172368799 Google Scholar

21. 

P. J. Campagnola and L. M. Loew, “Second-harmonic imaging microscopy for visualizing biomolecular arrays in cells, tissues and organisms,” Nat. Biotech., 21 1356 –1360 (2003). https://doi.org/10.1038/nbt894 Google Scholar

22. 

W. R. Zipfel, R. M. Williams, R. Christie, A. Y. Nikitin, B. T. Hyman, and W. W. Webb, “Live tissue intrinsic emission microscopy using multiphoton-excited native fluorescence and second harmonic generation,” Proc. Natl. Acad. Sci. USA, 100 7075 –7080 (2003). https://doi.org/10.1073/pnas.0832308100 Google Scholar

23. 

C. L. Evans, E. O. Potma, M. Puoris'haag, D. Côté, C. P. Lin, and X. S. Xie, “Chemical imaging of tissue in vivo with video-rate coherent anti-Stokes Raman scattering microscopy,” Proc. Natl. Acad. Sci. U.S.A., 102 (46), 16807 –16812 (2005). https://doi.org/10.1073/pnas.0508282102 Google Scholar

24. 

R. M. Williams, W. R. Zipfel, and W. W. Webb, “Interpreting SHG images of collagen I fibrils,” Biophys. J., 88 1377 –1386 (2005). https://doi.org/10.1529/biophysj.104.047308 Google Scholar

25. 

Y. Fu, H. Wang, R. Shi, and J. X. Cheng, “Second harmonic and sum frequency generation imaging of fibrous astroglial filaments in ex vivo spinal tissues,” Biophys. J., 92 3251 –3259 (2007). https://doi.org/10.1529/biophysj.106.089011 Google Scholar

26. 

T. Hellerer, C. Axang, C. Brackmann, P. Hillertz, M. Pilon, and A. Enejder, “Monitoring of lipid storage in Caenorhabditis elegans using coherent anti-Stokes Raman scattering (CARS) microscopy,” Proc. Natl. Acad. Sci. U.S.A., 104 (37), 14658 –14663 (2007). https://doi.org/10.1073/pnas.0703594104 Google Scholar

27. 

C. W. Freudiger, W. Min, B. G. Saar, S. Lu, G. R. Holtom, C. He, J. C. Tsai, J. X. Kang, and X. S. Xie, “Label-free biomedical imaging with high sensitivity by stimulated raman scattering microscopy,” Science, 322 (5909), 1857 –1861 (2008). https://doi.org/10.1126/science.1165758 Google Scholar

28. 

A. Zoumi, X. Lu, G. S. Kassab, and B. J. Tromberg, “Imging coronary artery microstructure using SHG and TPEF,” Biophys. J., 87 2778 –2786 (2004). https://doi.org/10.1529/biophysj.104.042887 Google Scholar

29. 

H. W. Wang, T. T. Le, and J. X. Cheng, “Label-free imaging of arterial cells and extracellular matrix using a multimodal nonlinear optical microscope,” Opt. Commun., 281 (7), 1813 –1822 (2008). https://doi.org/10.1016/j.optcom.2007.07.067 Google Scholar

30. 

Y. R. Shen, “Surface properties probed by SHG and SFG,” Nature, 337 519 –525 (1989). https://doi.org/10.1038/337519a0 Google Scholar

31. 

M. Zandvoort, W. Engels, K. Douma, L. Beckers, M. Egbrink, M. Daemen, and D. W. Slaaf, “TP microscopy for imaging of the vascular wall: a proof of concept study,” J. Vasc. Res., 41 54 –63 (2004). https://doi.org/10.1159/000076246 Google Scholar

32. 

K. Douma, R. T. A. Megens, S. Reitsma, L. Prinzen, D. W. Slaaf, and M. A. M. J. V. Zandvoort, “Two-photon lifetime imaging of fluorescent probes in intact blood vessels: A window to sub-cellular structural information and binding status,” Microsc. Res. Tech., 70 (5), 467 –475 (2007). https://doi.org/10.1002/jemt.20424 Google Scholar

33. 

T. T. Le, I. M. Langohr, M. J. Locker, M. Sturek, and J. X. Cheng, “Label-free molecular imaging of atherosclerotic lesions using multimodal nonlinear optical microscopy,” J. Biomed. Opt., 12 (5), 054007 (2007). https://doi.org/10.1117/1.2795437 Google Scholar

34. 

M. B. Lilledahl, O. A. Haugen, C. d.L. Davies, and L. O. Svaasand, “Characterization of vulnerable plaques by multiphoton microscopy,” J. Biomed. Opt., 12 (4), 044005 (2007). https://doi.org/10.1117/1.2772652 Google Scholar

35. 

H. W. Wang, I. M. Langohr, M. Sturek, and J.-X. Cheng, “Imaging and quantitative analysis of atherosclerotic lesions by CARS-based multimodal nonlinear optical microscopy,” Arterioscler. Thromb. Vasc. Biol., 29 (9), 1342 –1348 (2009). https://doi.org/10.1161/ATVBAHA.109.189316 Google Scholar

36. 

R. S. Lim, A. Kratzer, N. P. Barry, S. Miyazaki-Anzai, M. Miyazaki, W. W. Mantulin, M. Levi, E. O. Potma, and B. J. Tromberg, “Multimodal CARS microscopy determination of the impact of diet on macrophage infiltration and lipid accumulation on plaque formation in ApoE-deficient mice,” J. Lipid Res., 51 1729 –1737 (2010). https://doi.org/10.1194/jlr.M003616 Google Scholar

37. 

S.-H. Kim, E.-S. Lee, J. Y. Lee, E. S. Lee, B.-S. Lee, J. E. Park, and D. W. Moon, “Multiplex coherent anti-Stokes Raman spectroscopy images intact atheromatous lesions and concomitantly identifies distinct chemical profiles of atherosclerotic lipids,” Circ. Res., 106 (8), 1332 –1341 (2010). https://doi.org/10.1161/CIRCRESAHA.109.208678 Google Scholar

38. 

J. C. Garber, R. W. Barbee, J. T. Bielitzki, L. A. Clayton, J. C. Donovan, D. F. Kohn, N. S. Lipman, P. A. Locke, J. Melcher, F. W. Quimby, P. V. Turner, G. A. Wood, H. Würbel, L. Anestidou, Guide for the Care and Use of Laboratory Animals, National Academy Press, Washington, DC (2010). Google Scholar

39. 

I. N. Bratz, G. M. Dick, J. D. Tune, J. M. Edwards, Z. P. Neeb, U. D. Dincer, and M. Sturek, “Impaired capsaicin-induced relaxation of coronary arteries in a porcine model of the metabolic syndrome,” Am. J. Physiol. Heart Circ. Physiol., 294 (6), H2489 –2496 (2008). https://doi.org/10.1152/ajpheart.01191.2007 Google Scholar

40. 

M. Dyson, M. Alloosh, J. Vuchetich, E. Mokelke, and M. Sturek, “Components of metabolic syndrome and coronary artery disease in female Ossabaw swine fed excess atherogenic diet,” Comp. Med., 56 35 –45 (2006). https://doi.org/http://www.ingentaconnect.com/content/aalas/cm/2006/00000056/00000001/art00006 Google Scholar

41. 

P. G. Lloyd, A. J. Sheehy, J. M. Edwards, E. A. Mokelke, and M. Sturek, “Leukemia inhibitory factor is upregulated in coronary arteries of Ossabaw miniature swine after stent placement,” Coron. Artery Dis., 19 (4), 217 –226 (2008). https://doi.org/10.1097/MCA.0b013e3282f9d3be Google Scholar

42. 

J. X. Cheng and X. S. Xie, “Coherent anti-Stokes Raman scattering microscopy: instrumentation, theory, and applications,” J. Phys. Chem. B., 108 827 –840 (2004). https://doi.org/10.1021/jp035693v Google Scholar

43. 

H. Wang, Y. Fu, P. Zickmund, R. Shi, and J. X. Cheng, “Coherent anti-stokes Raman scattering imaging of axonl myelin in live spinal tissues,” Biophys. J., 89 581 –591 (2005). https://doi.org/10.1529/biophysj.105.061911 Google Scholar

44. 

D. Hasdai, D. R. Holmes, K. N. Garratt, W. D. Edwards, and A. Lerman, “Mechanical pressure and stretch release endothelin-1 from human atherosclerotic coronary arteries in vivo,” Circulation, 95 (2), 357 –362 (1997). https://doi.org/http://circ.ahajournals.org/cgi/content/abstract/95/2/357 Google Scholar

45. 

M. Sturek, E. A. Mokelke, J. P. Vuchetich, J. M. Edwards, M. Alloosh, and K. L. March, “In-stent neointimal hyperplasia is less fibrous in metabolic syndrome Ossabaw compared to lean Yucatan swine,” FASEB J., 20 (5), A1399 –1400 (2006). https://doi.org/http://www.fasebj.org/cgi/content/meeting_abstract/20/5/A1399-d Google Scholar

46. 

R. Komatsu, M. Ueda, T. Naruko, A. Kojima, and A. E. Becker, “Neointimal tissue response at sites of coronary stenting in humans: Macroscopic, histological, and immunohistochemical analyses,” Circulation, 98 (3), 224 –233 (1998). https://doi.org/http://circ.ahajournals.org/cgi/content/abstract/98/3/224 Google Scholar

47. 

A. V. Finn, G. Nakazawa, M. Joner, F. D. Kolodgie, E. K. Mont, H. K. Gold, and R. Virmani, “Vascular Responses to Drug Eluting Stents: Importance of Delayed Healing,” Arterioscler. Thromb. Vasc. Biol., 27 (7), 1500 –1510 (2007). https://doi.org/10.1161/ATVBAHA.107.144220 Google Scholar

48. 

G. Nakazawa, A. Finn, and R. Virmani, “Vascular Pathology of Drug-Eluting Stents,” Herz, 32 (4), 274 –280 (2007). https://doi.org/10.1007/s00059-007-2997-9 Google Scholar

49. 

J. Wiskirchen, W. Schöber, N. Schart, R. Kehlbach, A. Wersebe, G. Tepe, C. D. Claussen, and S. H. Duda, “The effects of paclitaxel on the three phases of restenosis: smooth muscle cell proliferation, migration, and matrix formation: an in vitro study,” Invest. Radiol., 39 (9), 565 –571 (2004). https://doi.org/10.1097/01.rli.0000133815.22434.55 Google Scholar

50. 

J. J. Nawarskas and L. A. Osborn, “Paclitaxel-eluting stents in coronary artery disease,” Am. J. Health Syst. Pharm., 62 (21), 2241 –2251 (2005). https://doi.org/10.2146/ajhp040621 Google Scholar

51. 

M. Joner, A. V. Finn, A. Farb, E. K. Mont, F. D. Kolodgie, E. Ladich, R. Kutys, K. Skorija, H. K. Gold, and R. Virmani, “Pathology of drug-eluting stents in humans: delayed healing and late thrombotic risk,” J. Am. Coll. Cardiol., 48 (1), 193 –202 (2006). https://doi.org/10.1016/j.jacc.2006.03.042 Google Scholar

52. 

C. J. Creel, M. A. Lovich, and E. R. Edelman, “Arterial paclitaxel distribution and deposition,” Circ. Res., 86 (8), 879 –884 (2000). https://doi.org/http://circres.ahajournals.org/cgi/content/abstract/86/8/879 Google Scholar

53. 

C.-W. Hwang, D. Wu, and E. R. Edelman, “Impact of transport and drug properties on the local pharmacology of drug-eluting stents,” Acute Cardiac. Care, 5 (1), 7 –12 (2003). https://doi.org/10.1080/14628840304614 Google Scholar
©(2011) Society of Photo-Optical Instrumentation Engineers (SPIE)
Han-Wei Wang, Ji-Xin Cheng, Michael Sturek, Vlad V. Simianu, and Matthew J. Locker "Stent-induced coronary artery stenosis characterized by multimodal nonlinear optical microscopy," Journal of Biomedical Optics 16(2), 021110 (1 February 2011). https://doi.org/10.1117/1.3533313
Published: 1 February 2011
Lens.org Logo
CITATIONS
Cited by 7 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Collagen

Arteries

Nonlinear optics

Image segmentation

Microscopy

Optical microscopy

Quantitative analysis

Back to Top