Scanning two-photon microscopy with upconverting lanthanide nanoparticles via Richardson-Lucy deconvolution

[+] Author Affiliations
Christian F. Gainer, Urs Utzinger, Marek Romanowski

The University of Arizona, Department of Biomedical Engineering, Tucson, Arizona, 85721-0240

J. Biomed. Opt. 17(7), 076003 (Jul 06, 2012). doi:10.1117/1.JBO.17.7.076003
History: Received March 9, 2012; Revised May 22, 2012; Accepted May 24, 2012
Text Size: A A A

Abstract.  The use of upconverting lanthanide nanoparticles in fast-scanning microscopy is hindered by a long luminescence decay time, which greatly blurs images acquired in a nondescanned mode. We demonstrate herein an image processing method based on Richardson-Lucy deconvolution that mitigates the detrimental effects of their luminescence lifetime. This technique generates images with lateral resolution on par with the system’s performance, 1.2μm, while maintaining an axial resolution of 5 μm or better at a scan rate comparable with traditional two-photon microscopy. Remarkably, this can be accomplished with near infrared excitation power densities of 850W/cm2, several orders of magnitude below those used in two-photon imaging with molecular fluorophores. By way of illustration, we introduce the use of lipids to coat and functionalize these nanoparticles, rendering them water dispersible and readily conjugated to biologically relevant ligands, in this case epidermal growth factor receptor antibody. This deconvolution technique combined with the functionalized nanoparticles will enable three-dimensional functional tissue imaging at exceptionally low excitation power densities.

Figures in this Article
© 2012 Society of Photo-Optical Instrumentation Engineers

Citation

Christian F. Gainer ; Urs Utzinger and Marek Romanowski
"Scanning two-photon microscopy with upconverting lanthanide nanoparticles via Richardson-Lucy deconvolution", J. Biomed. Opt. 17(7), 076003 (Jul 06, 2012). ; http://dx.doi.org/10.1117/1.JBO.17.7.076003


Access This Article
Sign In to Access Full Content
Please Wait... Processing your request... Please Wait.
Sign in or Create a personal account to Buy this article ($20 for members, $25 for non-members).
 
Your Session has timed out. Please sign back in to continue.
Sign In to Access Full Content

Tables

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging & repositioning the boxes below.

Related Book Chapters

Topic Collections

PubMed Articles
Advertisement

Buy this article ($18 for members, $25 for non-members).
Sign In