Errata

Errata: Discriminating model for diagnosis of basal cell carcinoma and melanoma in vitro based on the Raman spectra of selected biochemicals

[+] Author Affiliations
Landulfo Silveira, Fabrício Luiz Silveira, Renato Amaro Zângaro, Marcos Tadeu T. Pacheco

Universidade Camilo Castelo Branco—UNICASTELO, Biomedical Engineering Institute, Parque Tecnológico de São José dos Campos, Rod. Pres. Dutra, km 138, São José dos Campos, São Paulo, 12247-004, Brazil

Benito Bodanese

Universidade Comunitária da Região de Chapecó—UNOCHAPECÓ, Health Sciences Center—CCS, Av. Sen. Attílio Fontana, 591, Chapecó, Santa Catarina, 89809-000, Brazil

J. Biomed. Opt. 18(3), 039801 (Mar 05, 2013). doi:10.1117/1.JBO.18.3.039801
History:
Text Size: A A A

Open Access Open Access

This article [J. Biomed. Opt.. 17, , 077003  (2012)] was originally published online on 6 July 2012 with an error in Fig. 1. The erroneous figure was normalized by the peak, and the corrected figure is normalized by the area, causing the labeled peak positions to shift. The figure now matches the attributions presented in Table 2.

The corrected figure is reproduced below:

Graphic Jump LocationF1 :

Mean normalized Raman spectra of N, BCC, and MEL with vertical dotted lines labeling the peaks described in Table 2. Laser power: 150 mW, wavelength: 830 nm, spectral resolution: 2cm1, integration time: 2 s, number of scans: 10. Spectra were offset for clarity.

This article was corrected online on 1 March 2013.

© The Authors. Published by SPIE under a Creative Commons Attribution 3.0 Unported License. Distribution or reproduction of this work in whole or in part requires full attribution of the original publication, including its DOI.

Citation

Landulfo Silveira, Jr. ; Fabrício Luiz Silveira ; Benito Bodanese ; Renato Amaro Zângaro and Marcos Tadeu T. Pacheco
"Errata: Discriminating model for diagnosis of basal cell carcinoma and melanoma in vitro based on the Raman spectra of selected biochemicals", J. Biomed. Opt. 18(3), 039801 (Mar 05, 2013). ; http://dx.doi.org/10.1117/1.JBO.18.3.039801


Figures

Graphic Jump LocationF1 :

Mean normalized Raman spectra of N, BCC, and MEL with vertical dotted lines labeling the peaks described in Table 2. Laser power: 150 mW, wavelength: 830 nm, spectral resolution: 2cm1, integration time: 2 s, number of scans: 10. Spectra were offset for clarity.

Tables

References

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging & repositioning the boxes below.

Related Book Chapters

Topic Collections

PubMed Articles
Advertisement
  • Don't have an account?
  • Subscribe to the SPIE Digital Library
  • Create a FREE account to sign up for Digital Library content alerts and gain access to institutional subscriptions remotely.
Access This Article
Sign in or Create a personal account to Buy this article ($20 for members, $25 for non-members).
Access This Proceeding
Sign in or Create a personal account to Buy this article ($15 for members, $18 for non-members).
Access This Chapter

Access to SPIE eBooks is limited to subscribing institutions and is not available as part of a personal subscription. Print or electronic versions of individual SPIE books may be purchased via SPIE.org.