Abstract.  Fluorescence cystoscopy enhances detection of early bladder cancer. Water used to inflate the bladder during the procedure rapidly contains urine, which may contain fluorochromes. This frequently degrades fluorescence images. Samples of bladder washout fluid (BWF) or urine were collected (15 subjects). We studied their fluorescence properties and assessed changes induced by pH (4 to 9) and temperature (15°C to 41°C). A typical fluorescence spectrum of BWF features a main peak (excitation/emission: 320/420nm, FWHM=50/100nm) and a weaker (5% to 20% of main peak intensity), secondary peak (excitation/emission: 455/525nm, FWHM=80/50nm). Interpatient fluctuations of fluorescence intensity are observed. Fluorescence intensity decreases when temperature increases (max 30%) or pH values vary (max 25%). Neither approach is compatible with clinical settings. Fluorescence lifetime measurements suggest that 4-pyridoxic acid/riboflavin is the most likely molecule responsible for urine’s main/secondary fluorescence peak. Our measurements give an insight into the spectroscopy of the detrimental background fluorescence. This should be included in the optical design of fluorescence cystoscopes. We estimate that restricting the excitation range from 370–430 nm to 395–415 nm would reduce the BWF background by a factor 2.

Figures in this Article
© 2014 Society of Photo-Optical Instrumentation Engineers

Citation

Carla Martoccia ; Matthieu Zellweger ; Blaise Lovisa ; Patrice Jichlinski ; Hubert van den Bergh, et al.
"Optical spectroscopy of the bladder washout fluid to optimize fluorescence cystoscopy with Hexvix®", J. Biomed. Opt. 19(9), 097002 (Sep 10, 2014). ; http://dx.doi.org/10.1117/1.JBO.19.9.097002


Access This Article
Sign in or Create a personal account to Buy this article ($20 for members, $25 for non-members).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging & repositioning the boxes below.

Related Book Chapters

Topic Collections

PubMed Articles
Advertisement


 

  • Don't have an account?
  • Subscribe to the SPIE Digital Library
  • Create a FREE account to sign up for Digital Library content alerts and gain access to institutional subscriptions remotely.
Access This Article
Sign in or Create a personal account to Buy this article ($20 for members, $25 for non-members).
Access This Proceeding
Sign in or Create a personal account to Buy this article ($15 for members, $18 for non-members).
Access This Chapter

Access to SPIE eBooks is limited to subscribing institutions and is not available as part of a personal subscription. Print or electronic versions of individual SPIE books may be purchased via SPIE.org.