Research Papers: Imaging

Fast multislice fluorescence molecular tomography using sparsity-inducing regularization

[+] Author Affiliations
Sedigheh Marjaneh Hejazi

Tehran University of Medical Sciences, Medical Physics and Biomedical Engineering Department, School of Medicine, Tehran 1417613151, Iran

Tehran University of Medical Sciences, Research Center for Molecular and Cellular in Imaging, Bio-optical Imaging Group, Imam Khomeini Hospital, Keshavarz Boulevard, Tehran 1417613151, Iran

Saeed Sarkar

Tehran University of Medical Sciences, Medical Physics and Biomedical Engineering Department, School of Medicine, Tehran 1417613151, Iran

Tehran University of Medical Sciences, Research Center for Science and Technology in Medicine, Imam Khomeini Hospital, Keshavarz Boulevard, Tehran 1417613151, Iran

Ziba Darezereshki

Tehran University of Medical Sciences, Medical Physics and Biomedical Engineering Department, School of Medicine, Tehran 1417613151, Iran

J. Biomed. Opt. 21(2), 026012 (Feb 26, 2016). doi:10.1117/1.JBO.21.2.026012
History: Received September 30, 2015; Accepted February 4, 2016
Text Size: A A A

Abstract.  Fluorescence molecular tomography (FMT) is a rapidly growing imaging method that facilitates the recovery of small fluorescent targets within biological tissue. The major challenge facing the FMT reconstruction method is the ill-posed nature of the inverse problem. In order to overcome this problem, the acquisition of large FMT datasets and the utilization of a fast FMT reconstruction algorithm with sparsity regularization have been suggested recently. Therefore, the use of a joint L1/total-variation (TV) regularization as a means of solving the ill-posed FMT inverse problem is proposed. A comparative quantified analysis of regularization methods based on L1-norm and TV are performed using simulated datasets, and the results show that the fast composite splitting algorithm regularization method can ensure the accuracy and robustness of the FMT reconstruction. The feasibility of the proposed method is evaluated in an in vivo scenario for the subcutaneous implantation of a fluorescent-dye-filled capillary tube in a mouse, and also using hybrid FMT and x-ray computed tomography data. The results show that the proposed regularization overcomes the difficulties created by the ill-posed inverse problem.

Figures in this Article
© 2016 Society of Photo-Optical Instrumentation Engineers

Citation

Sedigheh Marjaneh Hejazi ; Saeed Sarkar and Ziba Darezereshki
"Fast multislice fluorescence molecular tomography using sparsity-inducing regularization", J. Biomed. Opt. 21(2), 026012 (Feb 26, 2016). ; http://dx.doi.org/10.1117/1.JBO.21.2.026012


Access This Article
Sign in or Create a personal account to Buy this article ($20 for members, $25 for non-members).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging & repositioning the boxes below.

Related Book Chapters

Topic Collections

Advertisement
  • Don't have an account?
  • Subscribe to the SPIE Digital Library
  • Create a FREE account to sign up for Digital Library content alerts and gain access to institutional subscriptions remotely.
Access This Article
Sign in or Create a personal account to Buy this article ($20 for members, $25 for non-members).
Access This Proceeding
Sign in or Create a personal account to Buy this article ($15 for members, $18 for non-members).
Access This Chapter

Access to SPIE eBooks is limited to subscribing institutions and is not available as part of a personal subscription. Print or electronic versions of individual SPIE books may be purchased via SPIE.org.