Research Papers: General

Assessment of blind source separation techniques for video-based cardiac pulse extraction

[+] Author Affiliations
Daniel Wedekind, Alexander Trumpp, Hagen Malberg, Sebastian Zaunseder

TU Dresden, Institute of Biomedical Engineering, Dresden, Germany

Frederik Gaetjen, Stefan Rasche, Klaus Matschke

TU Dresden, University Hospital Carl Gustav Carus Dresden, Herzzentrum Dresdem GmbH, Dresden, Germany

J. Biomed. Opt. 22(3), 035002 (Mar 03, 2017). doi:10.1117/1.JBO.22.3.035002
History: Received October 5, 2016; Accepted February 10, 2017
Text Size: A A A

Abstract.  Blind source separation (BSS) aims at separating useful signal content from distortions. In the contactless acquisition of vital signs by means of the camera-based photoplethysmogram (cbPPG), BSS has evolved the most widely used approach to extract the cardiac pulse. Despite its frequent application, there is no consensus about the optimal usage of BSS and its general benefit. This contribution investigates the performance of BSS to enhance the cardiac pulse from cbPPGs in dependency to varying input data characteristics. The BSS input conditions are controlled by an automated spatial preselection routine of regions of interest. Input data of different characteristics (wavelength, dominant frequency, and signal quality) from 18 postoperative cardiovascular patients are processed with standard BSS techniques, namely principal component analysis (PCA) and independent component analysis (ICA). The effect of BSS is assessed by the spectral signal-to-noise ratio (SNR) of the cardiac pulse. The preselection of cbPPGs, appears beneficial providing higher SNR compared to standard cbPPGs. Both, PCA and ICA yielded better outcomes by using monochrome inputs (green wavelength) instead of inputs of different wavelengths. PCA outperforms ICA for more homogeneous input signals. Moreover, for high input SNR, the application of ICA using standard contrast is likely to decrease the SNR.

Figures in this Article
© 2017 Society of Photo-Optical Instrumentation Engineers

Citation

Daniel Wedekind ; Alexander Trumpp ; Frederik Gaetjen ; Stefan Rasche ; Klaus Matschke, et al.
"Assessment of blind source separation techniques for video-based cardiac pulse extraction", J. Biomed. Opt. 22(3), 035002 (Mar 03, 2017). ; http://dx.doi.org/10.1117/1.JBO.22.3.035002


Access This Article
Sign in or Create a personal account to Buy this article ($20 for members, $25 for non-members).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging & repositioning the boxes below.

Related Book Chapters

Topic Collections

PubMed Articles
Advertisement
  • Don't have an account?
  • Subscribe to the SPIE Digital Library
  • Create a FREE account to sign up for Digital Library content alerts and gain access to institutional subscriptions remotely.
Access This Article
Sign in or Create a personal account to Buy this article ($20 for members, $25 for non-members).
Access This Proceeding
Sign in or Create a personal account to Buy this article ($15 for members, $18 for non-members).
Access This Chapter

Access to SPIE eBooks is limited to subscribing institutions and is not available as part of a personal subscription. Print or electronic versions of individual SPIE books may be purchased via SPIE.org.