13 July 2022 Empirical detector model for simulated breast exams with a dedicated breast CT scanner
Antonio Sarno, Giovanni Mettivier, Koen Michielsen, Juan José Pautasso, Ioannis Sechopoulos, Paolo Russo
Author Affiliations +
Proceedings Volume 12286, 16th International Workshop on Breast Imaging (IWBI2022); 1228605 (2022) https://doi.org/10.1117/12.2624249
Event: Sixteenth International Workshop on Breast Imaging, 2022, Leuven, Belgium
Abstract
This work proposes an empirical model for tuning spatial resolution and noise in simulated images in virtual clinical trials in x-ray breast imaging. In extending previous studies performed for direct conversion a-Se detectors used in digital mammography and digital breast tomosynthesis, this work introduces the model for the case of cone-beam computed tomography dedicated to the breast that uses a indirect conversion flat-panel detector. In the simulations, the detector is modeled as an absorbing layer whose material and thickness reflect those of the scintillator of the detector of a clinical scanner. The simulated images are then computed as a dose deposit map. The detector response curve, modulation transfer function (MTF) and noise power spectrum (NPS) were measured on a real detector. The same measurements were replicated in-silico for the simulated detector and scanner. The comparison of simulated and measured detector response curves permits to recover pixel values at the clinical scale. The difference between the simulated and measured MTFs permitted to introduce a linear filter for compensating simulated model simplification that determines a better spatial resolution in the simulated images with respect to real images. This filter presented a Gaussian shape in the Fourier domain with a standard deviation of 1.09 mm-1 , derived from those of the measured and simulated MTF curves, of 0.86 mm-1 and 1.41 mm-1 , respectively. Finally, the analysis of the NPS permits to compensate for noise characteristics due to the simulated model simplifications. The model applied to the simulated projection images produced MTF and normalized NPS in simulated 3D images, comparable to those obtained for the clinical scanner.
© (2022) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Antonio Sarno, Giovanni Mettivier, Koen Michielsen, Juan José Pautasso, Ioannis Sechopoulos, and Paolo Russo "Empirical detector model for simulated breast exams with a dedicated breast CT scanner", Proc. SPIE 12286, 16th International Workshop on Breast Imaging (IWBI2022), 1228605 (13 July 2022); https://doi.org/10.1117/12.2624249
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Sensors

Modulation transfer functions

Monte Carlo methods

Scanners

3D image processing

Breast

3D modeling

Back to Top