Paper
1 June 1991 Computed estimation of visual acuity after laser refractive keratectomy
Pascal O. Rol, Jean-Marie A. Parel, Khalil Hanna M.D.
Author Affiliations +
Proceedings Volume 1423, Ophthalmic Technologies; (1991) https://doi.org/10.1117/12.43966
Event: Optics, Electro-Optics, and Laser Applications in Science and Engineering, 1991, Los Angeles, CA, United States
Abstract
A number of surgical techniques has been developed to correct ametropia (refractive defaults) of the eye by changing the anterior corneal radius. Because the air-cornea interface makes up for about two-third of the refractive power of the eye, a refractive correction is obtained by a suitable photoablation of the cornea. For this purpose, e.g., an ArF excimer laser which emits a wavelength of 193 nm is being used. After a mechanical removal of the epithelium, the Bowman's layer and the corneal stroma are photoablated on typically 50% of the central surface of the cornea with various precomputed shapes. Methods using a variable diaphragm1 or a scanning slit2 are being utilized. After regrowth of the epithelium, a smooth interface with air develops itself, which can be attributed to a mechanical equilibration. Yet, SEM studies have shown that with such kind of treatments, irregularities can remain in the new stromal surface (Fig. 1). A possible explanation for this effect is associated with an inhomogeneous energy distribution of the laser beam profile3. To some extent, the stromal surface is equalized by the epithelial layer during healing& However, as the corneal epithelium and stroma have different refractive indices, a scatter of the incident light may result causing a haze in the cornea and a blur of the image at the retina. In such a case the resolution and the contrast performance of the eye which is expected from a successful operation, may be reduced. This study is an attempt to quantify the vision blur as a function of the deformation observed at the epithelium-stroma interface.
© (1991) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Pascal O. Rol, Jean-Marie A. Parel, and Khalil Hanna M.D. "Computed estimation of visual acuity after laser refractive keratectomy", Proc. SPIE 1423, Ophthalmic Technologies, (1 June 1991); https://doi.org/10.1117/12.43966
Lens.org Logo
CITATIONS
Cited by 2 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Cornea

Eye

Interfaces

Refractive index

Eye models

Scanning electron microscopy

Spherical lenses

RELATED CONTENT

Modeling and simulation of the human eye
Proceedings of SPIE (March 05 2007)
Retinal Thermal Injury
Proceedings of SPIE (October 07 1980)

Back to Top