Paper
8 October 2003 On the influence of the instillation time on the results of HAL (Hexvix) fluorescence detection of superficial bladder cancer
Patrice Jichlinski, Daniela Aymon, Georges A. Wagnieres, Alexandre Marti, Norbert Lange, Louis Guillou, Hans-Juerg Leisinger, Hubert van den Bergh
Author Affiliations +
Abstract
Hexyl aminolevulinate (HAL) fluorescence cystoscopy is being investigated as a new diagnostic tool for the detection of flat urothelial malignancies in bladder cancers. However, the influence of the bladder instillation time on the performance of this detection modality has not been addressed up to now. We report our initial experience comparing different instillation schedules of HAL cystoscopy in the diagnosis of superficial bladder cancer. A total of 718 fluorescent positive (433) and fluorescence negative (285) biopsies have been taken in the bladder of 143 patients using the Storz D-light fluorescence imaging system (Karl Storz, Tuttlingen, Germany) which allows both white and blue light (380-450 nm) bladder wall inspection. Following hospitalisation, 50 ml of HAL (8mM) phosphate buffer solution was instilled into the bladder of patients during one hour (1 hour protocol involving 57 patients), or during two hours followed by a two hours resting time after removal of the solution (2+2 hours protocol involving 86 patients). Both instillation subgroups were homogeneous in terms of proportion of high risk disease, previous BCG treatment and/or recurrent disease. This study indicates that the instillation duration does not influence the results of HAL (Hexvix) fluorescence cystoscopy in our conditions. Compared to the standard use of ALA, HAL (Hexvix) fluorescence cystoscopy allows a significant reduction of the instillation time (to less than one hour) without prejudicing the efficacy of the method, what represents a real advantage in daily clinical practice.
© (2003) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Patrice Jichlinski, Daniela Aymon, Georges A. Wagnieres, Alexandre Marti, Norbert Lange, Louis Guillou, Hans-Juerg Leisinger, and Hubert van den Bergh "On the influence of the instillation time on the results of HAL (Hexvix) fluorescence detection of superficial bladder cancer", Proc. SPIE 5141, Diagnostic Optical Spectroscopy in Biomedicine II, (8 October 2003); https://doi.org/10.1117/12.502218
Lens.org Logo
CITATIONS
Cited by 3 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Luminescence

Cystoscopy

Bladder

Biopsy

Bladder cancer

Tissues

Diagnostics

Back to Top