Paper
23 February 2010 The accuracy of a commercial spectrophotometer with single integrating sphere for measuring optical properties of turbid sample
Yang Zhang, Xiang Wen, ZhuDi Xu, Dan Zhu
Author Affiliations +
Abstract
A commercial spectrophotometer with an integrating sphere is widely used to measure the spectra of transmittance and reflectance of turbid sample, and then the optical properties can be deduced by inverse adding-doubling algorithm. Unfortunately, the accuracy of the measurement is not been elucidated completely. What's more, for the system, there still exists some other limits, i.e., the incident light is not collimated and size of light spot is too large compared with the sample port. Thus, the purpose of our study is to evaluate the accuracy of the commercial spectrophotometer with an integrating sphere for measuring optical properties of tissue phantom. Two phantom materials, Intralipid and Evans blue, and the mixture of these two, were chosen for the experiments. Mie theory was also introduced to calculate the reduced scattering coefficient according to the particle size distribution. The results show that the phantom measurement in conjunction with IAD algorithm enable the determination of scattering coefficient μs' to be better than 5% accuracy, absorption coefficient μa to be better than 10% accuracy when the optical depth of sample is between 1 and 10, and the albedo is bigger than 0.4. For scattering of samples during 1-5 mm-1, the error of μs' is smaller than 4%; whereas for absorbing of samples >0.4 mm-1, the maximum error is smaller than 8.3%. Therefore, spectrophotometer with an integrating sphere technique combined IAD algorithm is applicable for the measurements of optical properties for most tissue, and its repeatability and accuracy is good in proper scope of the optical depth and albedo.
© (2010) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Yang Zhang, Xiang Wen, ZhuDi Xu, and Dan Zhu "The accuracy of a commercial spectrophotometer with single integrating sphere for measuring optical properties of turbid sample", Proc. SPIE 7562, Optical Interactions with Tissues and Cells XXI, 756219 (23 February 2010); https://doi.org/10.1117/12.841821
Lens.org Logo
CITATIONS
Cited by 5 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Scattering

Absorption

Optical properties

Integrating spheres

Mie scattering

Tissue optics

Spectrophotometry

Back to Top