Paper
9 February 2012 A comparison of isotropic and anisotropic diffuse models in determining optical properties of fibrous tissue
Ali Shuaib, Gang Yao
Author Affiliations +
Abstract
We compared the isotropic and anisotropic diffuse models in retrieving the optical properties in fibrous samples from time-resolved reflectance measurements. A Monte Carlo model was used to simulate light propagation in a fibrous tissue consisting of aligned cylinders and spherical particles. Using the anisotropic diffuse model, the reduced scattering coefficients for both cylinder and background can be derived from a single time-resolved reflectance measured perpendicularly to the fiber direction. Using isotropic diffuse solution, these parameters can be derived from two measurements both parallel and perpendicular to the fiber direction. The simulation results also indicate that the derived optical properties are correct only for fibrous samples with small fiber diameter. For large fiber diameters, the reduced scattering coefficient of fibers needs to be corrected by fiber-size dependent factor. Overall, the isotropic diffuse model produced better results than the anisotropic model.
© (2012) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Ali Shuaib and Gang Yao "A comparison of isotropic and anisotropic diffuse models in determining optical properties of fibrous tissue", Proc. SPIE 8221, Optical Interactions with Tissue and Cells XXIII, 82211K (9 February 2012); https://doi.org/10.1117/12.909518
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Scattering

Reflectivity

Optical properties

Monte Carlo methods

Tissue optics

Light scattering

Absorption

Back to Top