Paper
29 August 2013 A novel microfluidic chip based on fiber sensor
Bo Su, Guoteng Duan, Xue Han
Author Affiliations +
Proceedings Volume 8914, International Symposium on Photoelectronic Detection and Imaging 2013: Fiber Optic Sensors and Optical Coherence Tomography; 891413 (2013) https://doi.org/10.1117/12.2034685
Event: ISPDI 2013 - Fifth International Symposium on Photoelectronic Detection and Imaging, 2013, Beijing, China
Abstract
We have fabricated a novel microfluidic chip based on fiber sensor with casting PDMS method. The optical fiber is used to transmit excitation light, so the diameter of the excitation beam is decreased to 93μm. In order to improve the coupling efficiency of the excitation light in the fiber, the optical fiber collimation device is used to couple beam. The microfluidic chip consists of multimode optical fiber, PDMS cover slab and PDMS base slab. The mould of cover slab is made through twice exposal, however the base slab is achieved using once exposal only. The depths of microfluidic channel and optical fiber channel in the PDMS cover slab are 50μm and 90μm, respectively, and the optical fiber channel in the PDMS base slab is only 40μm. This design can make the centers of the microfluidic channel and the fiber channel in the same point, so the microfluidic channel and the optical fiber can be aimed at easily. In addition, the size of microfluidic channel depth is near the size of light spot of optical fiber, so the detection sensitivity is improved without using the optical focusing system. The detection system of the microfluidic chip is manufactured and it composed of high voltage modules, darkroom, LED light source, photomultiplier and data acquisition circuit, moreover, the software of the detection system is developed. The high voltage modules with four 2kV are used to control the sample amount in the separation channel, so the sensitivity is improved. The microfluidic chip is placed in the darkroom to avoid the interference of external light. The high brightness blue light emitting diode (LED) is used as excitation light sources for inducing fluorescence detection through coupling the LED light into the optical fiber. The photomultiplier is used to amplify the fluorescence signals and the function of data acquisition circuit is data collection and data processing. Under the control of software, the experiment process can be implemented easily. As an application, the microfluidic chip is tested on the detection system for the separation experiment of FITC fluorescein and FITC-labeled amino acid. The experiments justify the feasibility of the chip.
© (2013) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Bo Su, Guoteng Duan, and Xue Han "A novel microfluidic chip based on fiber sensor", Proc. SPIE 8914, International Symposium on Photoelectronic Detection and Imaging 2013: Fiber Optic Sensors and Optical Coherence Tomography, 891413 (29 August 2013); https://doi.org/10.1117/12.2034685
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Microfluidics

Optical fibers

Semiconducting wafers

Light emitting diodes

Glasses

Light sources

Luminescence

RELATED CONTENT


Back to Top