Paper
4 November 1982 Tests And Quality Of The 3.5 Meter Primary Mirror Of The Max-Planck-Institut Fur Astronomie's Telescope At Calar Alto
Christoph Kuhne
Author Affiliations +
Abstract
The figuring of the 3.5 m primary mirror of the large telescope is described. The execution of final tests was carried out in a vertical test tunnel by means of a laser interferometer, using a compensating system. A special sequence of interferograms was applied aiming to suppress the thermal, accidental, and environmental influences. The wave front errors were evaluated accordingly. The results show that the standard deviation due to the mirror is 24 nm, out of total standard deviation of 49 nm taken as an avarage of 24 interferograms.
© (1982) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Christoph Kuhne "Tests And Quality Of The 3.5 Meter Primary Mirror Of The Max-Planck-Institut Fur Astronomie's Telescope At Calar Alto", Proc. SPIE 0332, Advanced Technology Optical Telescopes I, (4 November 1982); https://doi.org/10.1117/12.933532
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Mirrors

Wavefronts

Interferometers

Telescopes

Astronomical telescopes

Large telescopes

Monochromatic aberrations

RELATED CONTENT

The VLTI Auxiliary Telescopes: commissioning of AT1
Proceedings of SPIE (October 20 2004)
In-process metrology for large astronomical mirrors
Proceedings of SPIE (November 01 1990)
Testing the CHARA telescopes
Proceedings of SPIE (February 21 2003)
COSTAR phase II alignment description
Proceedings of SPIE (October 15 1993)

Back to Top