27 October 2021 Investigation of position and size for lymphedema with Infrared thermal imaging technology
Yi Feng Liu, Hsi-Chao Chen, Ying-Sheng Lin, Bo-Wei Lai, Min-Yi Jiang, Zheng-Ann Xiong, Wang-Tzu Hsi
Author Affiliations +
Abstract
The purpose is to utilize infrared-ray thermal imaging system to detect thermal temperature of the target, and the appearance of image by the digital image processing. The image of the infrared-ray thermal imager could get the related position and size of the lymphedema. The experiment measured the noncontact measurement of infrared images in the knee, calf belly and ankle of the patient's lower limb edema to observe the magnitude of its edema. The image was processed by Canny edge detection and marking method. The growing rate of knee, calf, and ankle were 4.35, 18.18, 13.64%, respectively. The position of calf had the largest growing rate than that of other positions.
© (2021) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Yi Feng Liu, Hsi-Chao Chen, Ying-Sheng Lin, Bo-Wei Lai, Min-Yi Jiang, Zheng-Ann Xiong, and Wang-Tzu Hsi "Investigation of position and size for lymphedema with Infrared thermal imaging technology", Proc. SPIE 11925, Biomedical Imaging and Sensing Conference 2021, 119251F (27 October 2021); https://doi.org/10.1117/12.2615879