1 June 1991 Colorimetric calibration for scanners and media
Po-Chieh Hung
Author Affiliations +
Proceedings Volume 1448, Camera and Input Scanner Systems; (1991) https://doi.org/10.1117/12.45355
Event: Electronic Imaging '91, 1991, San Jose, CA, United States
Abstract
Colorimetric calibration techniques were studied for scanners that do not adhere to colorimetric requirements (the Luther condition) from the aspects of accuracy and signal noise. A newly developed calibration technique was compared with conventional polynomial regression models and was found to be more accurate. Computer simulations were performed to find the relationship between scanner responsivities and resultant chroma noise. The scanner matching the Luther condition exhibits larger chroma noise than a scanner having three separated responsivities due to the overlap among responsivities of each channel.
© (1991) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Po-Chieh Hung "Colorimetric calibration for scanners and media", Proc. SPIE 1448, Camera and Input Scanner Systems, (1 June 1991); https://doi.org/10.1117/12.45355
Lens.org Logo
CITATIONS
Cited by 69 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Scanners

Calibration

Interference (communication)

Mathematical modeling

Photography

Cameras

Printing

RELATED CONTENT

W1.1 macro uniformity
Proceedings of SPIE (January 19 2009)
ICC profiles: are we better off without them?
Proceedings of SPIE (January 25 2011)
Input calibration for negative originals
Proceedings of SPIE (April 10 1995)

Back to Top