Paper
1 August 2003 Health monitoring techniques using integrated sensors
Klaus Pfleiderer, Rainer Stoessel, Gerhard Busse
Author Affiliations +
Abstract
Advanced high performance materials and components such as CFRP, GFRP and Smart Structures require improved testing techniques. The first part of our contribution deals with nonlinear vibrometry as a defect selective non-destructive testing method. This method uses higher harmonics (which are generated only at defects) to locate the defect by scanning across the surface of the sample with a laser interferometer. For input coupling of the elastic wave both an external (like ultrasound welding converters) or internal (integrated piezo actuators) excitation source can be used. The external detection tools are a microphone or a scanning laser vibrometer. With this technique, we characterized Smart Structures made of aerospace materials and composites with embedded piezoelectric actuators. The next part is about health monitoring techniques and diagnostics where integrated elements are used for excitation and detection. Thus, we monitored the transfer function over a large frequency spectrum and especially its changes caused e.g. by defects. Changes in the properties of structures by fatigue, impacts, and thermoplasticity have been successfully observed. Also the changes in reinforced plastics under tensile stress have been monitored. The results were correlated with destructive measurements. For health monitoring we also present the impedance analysis of embedded piezo ceramic sensors. A defect causes changes in the modal response of the hole structure and that effect can be detected using the phase angle of the electric impedance of the piezo element. Additionally some types of defects cause a non-linear behavior of the structure which was verified by extracting higher harmonics as a reaction to sinusoidal single frequency excitation.
© (2003) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Klaus Pfleiderer, Rainer Stoessel, and Gerhard Busse "Health monitoring techniques using integrated sensors", Proc. SPIE 5046, Nondestructive Evaluation and Health Monitoring of Aerospace Materials and Composites II, (1 August 2003); https://doi.org/10.1117/12.488048
Lens.org Logo
CITATIONS
Cited by 2 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Actuators

Sensors

Receivers

Transmitters

Smart structures

Ultrasonography

Vibrometry

Back to Top