20 April 2005 Flat panel detector-based cone beam CT lung imaging: preliminary system evaluation
Ruola Ning, David Conover, Yong Yu, Weixing Cai, Xianghua Lu
Author Affiliations +
Abstract
The purpose of this study is to perform a preliminary evaluation of a newly constructed flat panel detector (FPD)-based system for cone beam CT imaging applications. A prototype flat-panel detector-based cone beam CT imaging system has been designed and constructed by modifying a GE HiSpeed Advantage CT scanner. The prototype consists of a modified GE CT HiSpeed Advantage CT gantry, an x-ray tube, a 397mm x 298mm Varian PaxScan 4030CB real time flat-panel detector mounted on the gantry, a CT table and an on-gantry PC to control image acquisition. Another PC workstation serving as an operating console controls the CT gantry and CT table, and sends trigger pulses to dedicated electronic interface modules to control radiographic exposure and to initiate data acquisition. Captured image data sets are first stored in the on-gantry computer and then downloaded from the on-gantry PC to the operating console for high-speed 3D image reconstruction. During data acquisition, the x-ray tube and the FPD can be rotated on the gantry over Nx360 degrees due to integrated slip ring technology. With a single scan, this device is able to acquire up to three hundred two-dimensional projections (1024 x 768 x 16 bits) for direct 3D reconstruction within 10 seconds. This system was used for a series of preliminary phantom studies and small animal studies. Using the continuous scan mode of the scanner, a few hundred projections were acquired for all volume scans. Direct 3D reconstructions were obtained to evaluate the system for cone beam CT for lung imaging applications. The preliminary results indicate that the newly built flat panel detector-based cone beam CT scanner works as expected and the low contrast resolution of the FPD-based CBCT system is approaching that of a multi-slice CT.
© (2005) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Ruola Ning, David Conover, Yong Yu, Weixing Cai, and Xianghua Lu "Flat panel detector-based cone beam CT lung imaging: preliminary system evaluation", Proc. SPIE 5745, Medical Imaging 2005: Physics of Medical Imaging, (20 April 2005); https://doi.org/10.1117/12.596114
Lens.org Logo
CITATIONS
Cited by 3 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
X-ray computed tomography

Sensors

Prototyping

Data acquisition

Imaging systems

Scanners

Tumors

Back to Top