16 March 2007 Investigation of the use of photon counting x-ray detectors with energy discrimination capability for material decomposition in micro-computed tomography
Author Affiliations +
Abstract
Recently developed solid-state detectors combined with high-speed ASICs that allow individual pixel pulse processing may prove useful as detectors for small animal micro-computed tomography. One appealing feature of these photon-counting x-ray detectors (PCXDs) is their ability to discriminate between photons with different energies and count them in a small number (2-5) of energy windows. The data in these energy windows may be thought of as arising from multiple simultaneous x-ray beams with individual energy spectra, and could thus potentially be used to perform material composition analysis. The goal of this paper was to investigate the potential advantages of PCXDs with multiple energy window counting capability as compared to traditional integrating detectors combined with acquisition of images using x-ray beams with 2 different kVps. For the PCXDs, we investigated 3 potential sources of crosstalk: scatter in the object and detector, limited energy resolution, and pulse piluep. Using Monte Carlo simulations, we showed that scatter in the object and detector results in relatively little crosstalk between the data in the energy windows. To study the effects of energy resolution and pulse-pileup, we performed simulations evaluating the accuracy and precision of basis decomposition using a detector with 2 or 5 energy windows and a single kVp compared to an dual kVp acquisitions with an integrating detector. We found that, for noisy data, the precision of estimating the thickness of two basis materials for a range of material compositions was better for the single kVp multiple energy window acquisitions compared to the dual kVp acquisitions with an integrating detector. The advantage of the multi-window acquisition was somewhat reduced when the energy resolution was reduced to 10 keV and when pulse pileup was included, but standard deviations of the estimated thicknesses remained better by more than a factor of 2.
© (2007) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
E. C. Frey, X. Wang, Y. Du, K. Taguchi, J. Xu, and B. M. W. Tsui "Investigation of the use of photon counting x-ray detectors with energy discrimination capability for material decomposition in micro-computed tomography", Proc. SPIE 6510, Medical Imaging 2007: Physics of Medical Imaging, 65100A (16 March 2007); https://doi.org/10.1117/12.711711
Lens.org Logo
CITATIONS
Cited by 32 scholarly publications and 1 patent.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Sensors

X-rays

Polymethylmethacrylate

X-ray detectors

Calibration

Monte Carlo methods

Photon counting

Back to Top