19 March 2008 Development of a quality control program for a cone beam CT imaging system
Author Affiliations +
Abstract
Routine quality control assessments of medical equipment are crucial for an accurate patient medical treatment as well as for the safety of the patient and staff involved. These regular evaluations become especially important when dealing with radiation-emitting equipment. Therefore, a quality control (QC) program has been developed to quantitatively evaluate imaging systems by measuring standard parameters related to image quality such as the Modulation Transfer Function (MTF), the Noise Power Spectrum (NPS), uniformity, linearity and noise level among others. First, the methods of evaluating the aforementioned parameters have been investigated using a cone beam CT imaging system. Different exposure techniques, phantoms, acquisition modes of the flat panel detector (FPD) and reconstruction algorithms relevant to a clinical environment were all included in this investigation. Second, using the results of the first part of this study, a set of parameters for the QC program was established that yields both, an accurate depiction of the system image quality and an integrated program for easy and practical implementation. Lastly, this QC program will be implemented and practiced in our cone beam CT imaging system. The results using our available phantoms demonstrate that the QC program is adequate to evaluate stability and image quality of this system since it provides comparable parameters to other QC programs.
© (2008) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Ricardo Betancourt Benítez, Ruola Ning, David Conover, Yan Zhang, and Weixing Cai "Development of a quality control program for a cone beam CT imaging system", Proc. SPIE 6913, Medical Imaging 2008: Physics of Medical Imaging, 691356 (19 March 2008); https://doi.org/10.1117/12.770427
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Imaging systems

Image quality

Modulation transfer functions

Computed tomography

Spatial resolution

X-ray computed tomography

Control systems

RELATED CONTENT

Flat panel cone beam CT on a mobile isocentric C...
Proceedings of SPIE (May 03 2002)
A new paradigm in portal imaging QA fast measurements...
Proceedings of SPIE (March 15 2007)
Volumetric cone beam CT system based on a 41x41 cm2...
Proceedings of SPIE (June 28 2001)
A challenge for high speed and high resolution CT for...
Proceedings of SPIE (April 01 2024)
Image Quality: Two Current Issues
Proceedings of SPIE (April 01 1987)

Back to Top