13 March 2009 Noise correlation in CBCT projection data and its application for noise reduction in low-dose CBCT
Jing Wang, Anwei Chai, Lei Xing
Author Affiliations +
Proceedings Volume 7258, Medical Imaging 2009: Physics of Medical Imaging; 72582D (2009) https://doi.org/10.1117/12.813891
Event: SPIE Medical Imaging, 2009, Lake Buena Vista (Orlando Area), Florida, United States
Abstract
There are growing interests in using cone-beam computed tomography (CBCT) for patient treatment position setup and dose evaluation in radiation therapy. The repeated use of CBCT during the course of a treatment has raised concerns of extra radiation dose delivered to patients. One way to reduce radiation dose delivered to patients during CBCT procedure is to acquire CT projection data with a lower mAs level. However, the image quality of the projection image and the reconstructed CBCT image will degrade due to excessive quantum noise as a result of low mAs protocol. In this work, we first studied the noise properties of CBCT projection data from repeated scan and then improved low-dose CBCT image quality by restoring CBCT projection images based on an improved noise model of CBCT projection data. Analysis of repeated measurements show that noise is correlated among nearest neighbors in projection data, i.e., covariance matrix of projection data noise is non-diagonal. The covariance matrix of noise provides the knowledge of second-order statistics of noise, which may lead to more accurate estimation for statistical image reconstruction and restoration algorithm. We constructed the penalized weighted least-squares (PWLS) objective function by incorporating the noise correlation of CBCT projection data. The optimal solution of the line integrals is then estimated by minimizing the PWLS objective function. A quality assurance phantom was used to evaluate the presented algorithm for noise reduction in low-dose CBCT.
© (2009) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Jing Wang, Anwei Chai, and Lei Xing "Noise correlation in CBCT projection data and its application for noise reduction in low-dose CBCT", Proc. SPIE 7258, Medical Imaging 2009: Physics of Medical Imaging, 72582D (13 March 2009); https://doi.org/10.1117/12.813891
Lens.org Logo
CITATIONS
Cited by 4 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Image quality

Reconstruction algorithms

Computed tomography

Sensors

Data modeling

Denoising

Image restoration

Back to Top