Paper
27 March 2009 Nonrigid correction of interleaving artefacts in pelvic MRI
Jason Dowling, Pierrick Bourgeat, David Raffelt, Jurgen Fripp, Peter B. Greer, Jacqueline Patterson, James Denham, Sanjiv Gupta, Colin Tang, Peter Stanwell, Sébastien Ourselin, Olivier Salvado
Author Affiliations +
Proceedings Volume 7259, Medical Imaging 2009: Image Processing; 72592P (2009) https://doi.org/10.1117/12.812460
Event: SPIE Medical Imaging, 2009, Lake Buena Vista (Orlando Area), Florida, United States
Abstract
This paper presents a novel method to reduce the effects of interleaving motion artefacts in single-plane MR scanning of the pelvic region without the need for k-space information. Interleaved image (or multipacket) acquisition is frequently used to reduce cross-talk and scanning time during full pelvic MR scans. Patient motion during interleaved acquisition can result in non-linear "staircase" imaging artefacts which are most visible on sagittal and coronal reconstructions. These artefacts can affect the segmentation of organs, registration, and visualization. A fast method has been implemented to replace artefact affected slices in a packet with interpolated slices based on Penney et al (2004) whose method involves the registration of neighbouring slices to obtain correspondences, followed by linear interpolation of voxel intensities along the displacement fields. This interpolation method has been applied to correct motion affected MRI volumes by firstly creating a new volume where every axial slice from the artefact affected packet is removed and replaced with an interpolated slice and then secondly for each of these slices, 2D non-rigid registration is used to register each original axial slice back to its matching interpolated slice. Results show visible improvements in artefacts particularly in sagittal and coronal image reconstructions, and should result in improved intensity based non-rigid registration results between MR scans (for example for atlas based automatic segmentation). Further validation was performed on simulated interleaving artefacts which were applied to an artefact free volume. Results obtained on prostate cancer radiotherapy treatment planning contouring were inconclusive and require further investigation.
© (2009) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Jason Dowling, Pierrick Bourgeat, David Raffelt, Jurgen Fripp, Peter B. Greer, Jacqueline Patterson, James Denham, Sanjiv Gupta, Colin Tang, Peter Stanwell, Sébastien Ourselin, and Olivier Salvado "Nonrigid correction of interleaving artefacts in pelvic MRI", Proc. SPIE 7259, Medical Imaging 2009: Image Processing, 72592P (27 March 2009); https://doi.org/10.1117/12.812460
Lens.org Logo
CITATIONS
Cited by 7 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Magnetic resonance imaging

Bladder

Prostate

Rectum

Radiotherapy

Image registration

Image segmentation

Back to Top