22 May 2009 Optimization of accurate SEM imaging by use of artificial images
Petr Cizmar, András E. Vladár, Michael T. Postek
Author Affiliations +
Proceedings Volume 7378, Scanning Microscopy 2009; 737815 (2009) https://doi.org/10.1117/12.823415
Event: SPIE Scanning Microscopy, 2009, Monterey, California, United States
Abstract
Today the vast majority of the scanning electron microscopes (SEMs) are incapable of taking repeatable and accurate images at high magnifications. Geometric distortions are common, so are drift, vibration, and problems related to disturbing electro-magnetic fields, contamination. These issues tend to degrade the quality of the image. Hence, in many cases it is not the focusing ability of the electron optical column, but these factors that limit the achievable resolution, repeatability and accuracy. This is a significant issue for nanometer-scale measurements, because the errors are many times greater than the measured distances. However, there are new image acquisition techniques that could improve the accuracy and repeatability of such measurements. One of these techniques is being developed at National Institute of Standards and Technology (NIST). This technique is based on cross-correlation combined with frequency filtering. Because the power this technique strongly depends on many conditions, like shape and periodicity of the sample features, noise, frequencies of the vibrations, etc., it needs to be properly evaluated and limits of usability of the technique should be specified. For this, a statistically significant number of SEM images varying in all of these parameters is necessary and the parameters must be known. Unfortunately, this is impossible to achieve using an SEM, because most of these parameters are random and the instrument parameters are unknown. A possible solution is to use the artificial SEM images, which can simulate these effects repeatably and deterministically. It is not an issue to generate a large number of such images in a reasonable time. The artificial image generator was developed at NIST originally for the evaluation of resolution-calculation techniques, but it is also very usable for assessment of new imaging techniques too. The new version of the generator is being developed at NIST. It allows for modeling different types of samples and several new effects, which also allow for taking into account the different characteristics of different SEMs. This paper describes, how the artificial images are built and how they may be used to improve the new SEM imaging techniques.
© (2009) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Petr Cizmar, András E. Vladár, and Michael T. Postek "Optimization of accurate SEM imaging by use of artificial images", Proc. SPIE 7378, Scanning Microscopy 2009, 737815 (22 May 2009); https://doi.org/10.1117/12.823415
Lens.org Logo
CITATIONS
Cited by 11 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Scanning electron microscopy

Distance measurement

Contamination

Current controlled current source

Electron microscopes

Image acquisition

Image quality

Back to Top