Paper
3 October 2011 Inter-laboratory comparison of UV-light sources for accelerated durability testing of PV modules
Daniel Philipp, Karl-Anders Weiss, Michael Koehl
Author Affiliations +
Abstract
Accelerated testing of the durability of materials exposed to natural weathering requires testing of the UV stability, especially for polymeric materials. The type approval testing of PV-modules according to the standards IEC 61215 and IEC 61646 includes a so-called UV-preconditioning test with a total UV dose of 15 kWh/m2. Fraunhofer ISE performed an Inter-laboratory comparison of UV-light sources in accredited test labs and in test centres of major PV module manufacturers. One topic was the spectral measurement of the used UV sources. Another main issue was the comparison of the integral measurements by the sensors used for control of the tests. Errors up to 120% were found.
© (2011) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Daniel Philipp, Karl-Anders Weiss, and Michael Koehl "Inter-laboratory comparison of UV-light sources for accelerated durability testing of PV modules", Proc. SPIE 8112, Reliability of Photovoltaic Cells, Modules, Components, and Systems IV, 81120G (3 October 2011); https://doi.org/10.1117/12.893525
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Ultraviolet radiation

Solar cells

Ultraviolet sources

Polymers

Sensors

Calibration

Radiometry

Back to Top