22 February 2012 Diagnostic accuracy of digital mammography versus tomosynthesis: effect of radiologists' experience
F. Zanca, M. Wallis, E. Moa, K. Leifland, M. Danielsson, R. Oyen, H. Bosmans
Author Affiliations +
Abstract
Purpose: To investigate whether readers' experience affects performance in a study comparing 2D digital mammography (2D) with 2-view (CC and MLO) or 1-view (MLO) tomosynthesis. Materials and Methods: One-hundred-thirty 2D cases were collected from screening assessment and referral clinics; 64 of the cases had verified abnormalities and the remaining were confirmed normal. Two-view tomosynthesis images were obtained from the same patients. Ten accredited readers (5 with ≥ 10 years experience in mammography and 5 with < 10 years) classified the cases in terms of malignancy (rate 0-5), and recall (yes/no), for both modalities. A second experiment was performed with the same cases, with 10 other readers (again 5 experienced / 5 less experienced), but using 2D and 1-view tomosynthesis as the two modalities. The multi-reader-multi-case ROC method was applied and the significance of diagnostic accuracy difference of 2D vs tomosynthesis was calculated, as a function of experience and for each experiment. Recall rate (RR) on malignant and benign cases was also calculated, along with reading time. Results: No significant difference was reached between 2D and 2-view tomosynthesis for experienced readers (pvalue= 0.25); for less experienced readers the p-value was significant (0.03). No significant difference was found between 2D and 1-view tomosynthesis, independent of readers' experience. RR for benign cases decreased for tomosynthesis (for booth 1- and 2-view), independent of experience. Average reading time per case was 79 s (range 65- 91 s) and 134 s (range 119-158 s) for experienced readers; 56 s (range 46-67 s) and 115s (range 97-142 s) for nonexperienced, for 2D and 2-view tomosynthesis respectively. Reading time was 74 s (range 43-98 s) and 99 s (range 73- 117 s) for experienced readers; 74 s (range 62-85 s) and 94 s (range 82-137 s) for non-experienced, for 2D and 1-view tomosynthesis respectively. Conclusions: For experienced readers, there is no evidence of improved diagnostic accuracy when using 2-view or 1- view tomosynthesis, while less experienced readers perform better with 2-view tomosynthesis than 2D images. Tomosynthesis reduces the number of recall of benign cases, without hindering cancer detection.
© (2012) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
F. Zanca, M. Wallis, E. Moa, K. Leifland, M. Danielsson, R. Oyen, and H. Bosmans "Diagnostic accuracy of digital mammography versus tomosynthesis: effect of radiologists' experience", Proc. SPIE 8318, Medical Imaging 2012: Image Perception, Observer Performance, and Technology Assessment, 83180W (22 February 2012); https://doi.org/10.1117/12.905276
Lens.org Logo
CITATIONS
Cited by 4 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Diagnostics

Mammography

Digital mammography

Breast

Statistical analysis

Cancer

Digital breast tomosynthesis

Back to Top