Paper
26 September 2013 Calibration of the Soft X-ray Telescopes (SXT) onboard the ASTRO-H satellite
Yang Soong, Takashi Okajima, Peter J. Serlemitsos, Devin Hahne
Author Affiliations +
Abstract

ASTRO-H is an astrophysics satellite dedicated for non-dispersive X-ray spectroscopic study on selective celestial X-ray sources. Among the onboard instruments there are four Wolter-I X-ray mirrors of their reflectors’ figure in conical approximation. Two of the four are soft X-ray mirrors1, of which the energy range is from a few hundred eV to 15 keV. The focal point instruments will be a calorimeter (SXS) and a CCD camera (SXI), respectively. The mirrors were in quadrant configuration with photons being reflected consecutively in the primary and secondary stage before landing on the focal plane of 5.6 m away from the interface between the two stages. The reflectors of the mirror are made of heat-formed aluminum substrate of the thickness gauged of 152 μm, 229 μm, and 305 μm of the alloy 5052 H-19, followed by epoxy replication on gold-sputtered smooth Pyrex cylindrical mandrels to acquire the X-ray reflective surface. The epoxy layer is 10 μm nominal and surface gold layer of 0.2 μm. Improvements on angular response over its predecessors, e.g. Astro-E1/Suzaku mirrors, come from error reduction on the figure, the roundness, and the grazing angle/radius mismatching of the reflecting surface, and tighter specs and mechanical strength on supporting structure to reduce the reflector positioning and the assembly errors.

Each soft x-ray telescope (SXT), FM1 or FM2, were integrated from four independent quadrants of mirrors. The stray-light baffles, in quadrant configuration, were mounted onto the integrated mirror. Thermal control units were attached to the perimeter of the integrated mirror to keep the mirror within operating temperature in space. The completed instrument went through a series of optical alignment, thus made the quadrant images confocal and their optical axes in parallel to achieve highest throughput possible. Environmental tests were carried out, and optical quality of the telescopes has been confirmed. The optical and x-ray calibrations also include: angular resolution, effective area in the energy range of ~ 0.4 – 12keV, off-axis response, etc. Some of those are being carried out by our counterpart at JAXA/ISAS, Japan. We report the calibration results of the FM1 and FM2 that were obtained at Goddard Space Flight Center.

© (2013) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Yang Soong, Takashi Okajima, Peter J. Serlemitsos, and Devin Hahne "Calibration of the Soft X-ray Telescopes (SXT) onboard the ASTRO-H satellite", Proc. SPIE 8861, Optics for EUV, X-Ray, and Gamma-Ray Astronomy VI, 88610H (26 September 2013); https://doi.org/10.1117/12.2024116
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Mirrors

Reflectors

X-rays

Calibration

Image quality

X-ray imaging

X-ray optics

RELATED CONTENT

ASTRO-H Soft X-ray Telescope (SXT)
Proceedings of SPIE (July 31 2014)
The NeXT x-ray telescope system: status update
Proceedings of SPIE (July 15 2008)
Constellation-X spectroscopy x-ray telescope (SXT)
Proceedings of SPIE (March 11 2003)
ASTRO-H Soft X-ray Telescope (SXT)
Proceedings of SPIE (September 30 2011)

Back to Top