Paper
11 March 2014 Mammographic density measurement: a comparison of automated volumetric density measurement to BIRADS
Author Affiliations +
Abstract
The aim of this study is to compare mammographic breast density assessment with automated volumetric software with Breast Imaging Reporting and Data System (BIRADS) categorization by radiologists on two imaging systems. A data set of 120 mammograms was classified by twenty American Board of Radiology (ABR) Examiners. The mammograms were of 20 women (mean age, 60 years; range, 42–89 years). These women were image twice one year apart either on GE system or Hologic system. These images also had their volumetric density classified by using Volpara Density Grade (VDG). The radiologists were asked to estimate the mammographic density according to BIRADS categories (1-4). There was a moderate agreement between VDG classification and radiologist BIRADS density shown with Cohen’s Kappa (κ=0.45; p<0.001). Radiologists estimated percentage density to be lower by an average of 0.37 for the Hologic system, the radiologist’s BIRADS having a mean of 2.05 and the mean VDG higher at 2.42(t= -8.88; p<0.001). VDG and radiologist’s BIRADS showed a positive strong correlation (r=0.87; p<0.001). Radiologist BIRADS and VDG AvBD% also showed a strong positive correlation (r=0.86; p<0.001). There was a large spread of radiologist’s BIRADS categories for each of the VDG AvBD% classifications. Using Volpara, the Hologic system showed a lower mean AvBD% (9.5 vs. 9.6). However using BIRADS the Hologic systems showed a lower mean (2.05 vs. 2.22). Automated systems demonstrated higher internal validity. The results demonstrated a moderate agreement and a strong correlation between VDG classification and radiologist BIRADS density assessment.

Publisher’s Note: This paper, originally published on 3/11/14, was replaced with a corrected/revised version on 8/1/14. If you downloaded the original PDF but are unable to access the revision, please contact SPIE Digital Library Customer Service for assistance.
© (2014) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Mark F. McEntee and Christine N. Damases "Mammographic density measurement: a comparison of automated volumetric density measurement to BIRADS", Proc. SPIE 9037, Medical Imaging 2014: Image Perception, Observer Performance, and Technology Assessment, 90370T (11 March 2014); https://doi.org/10.1117/12.2042966
Lens.org Logo
CITATIONS
Cited by 8 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Breast

Imaging systems

Mammography

Tissues

Breast imaging

Cancer

Radiology

Back to Top