31 March 2016 A technique for multi-dimensional optimization of radiation dose, contrast dose, and image quality in CT imaging
Pooyan Sahbaee, Ehsan Abadi, Jeremiah Sanders, Marc Becchetti, Yakun Zhang, Greeshma Agasthya, Paul Segars, Ehsan Samei
Author Affiliations +
Abstract
The purpose of this study was to substantiate the interdependency of image quality, radiation dose, and contrast material dose in CT towards the patient-specific optimization of the imaging protocols. The study deployed two phantom platforms. First, a variable sized phantom containing an iodinated insert was imaged on a representative CT scanner at multiple CTDI values. The contrast and noise were measured from the reconstructed images for each phantom diameter. Linearly related to iodine-concentration, contrast to noise ratio (CNR), was calculated for different iodine-concentration levels. Second, the analysis was extended to a recently developed suit of 58 virtual human models (5D-XCAT) with added contrast dynamics. Emulating a contrast-enhanced abdominal image procedure and targeting a peak-enhancement in aorta, each XCAT phantom was “imaged” using a CT simulation platform. 3D surfaces for each patient/size established the relationship between iodine-concentration, dose, and CNR. The Sensitivity of Ratio (SR), defined as ratio of change in iodine-concentration versus dose to yield a constant change in CNR was calculated and compared at high and low radiation dose for both phantom platforms. The results show that sensitivity of CNR to iodine concentration is larger at high radiation dose (up to 73%). The SR results were highly affected by radiation dose metric; CTDI or organ dose. Furthermore, results showed that the presence of contrast material could have a profound impact on optimization results (up to 45%).
© (2016) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Pooyan Sahbaee, Ehsan Abadi, Jeremiah Sanders, Marc Becchetti, Yakun Zhang, Greeshma Agasthya, Paul Segars, and Ehsan Samei "A technique for multi-dimensional optimization of radiation dose, contrast dose, and image quality in CT imaging", Proc. SPIE 9783, Medical Imaging 2016: Physics of Medical Imaging, 97833F (31 March 2016); https://doi.org/10.1117/12.2216516
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Computed tomography

Image quality

Iodine

3D modeling

CT reconstruction

Mercury

Scanners

Back to Top