The first results of high-speed atomic oxygen (AO) irradiation tests for atomically thin single-layer graphene sheets are presented as space environmental tolerance evaluation tests toward application in astronomy. The single-layer graphene sample was prepared without a metal coating, and high-speed AO irradiation tests were conducted with an averaged velocity of |
1.IntroductionThin-film devices have been used in a wide variety of ways not only as filters and sample support grids used in X-ray synchrotron radiation facilities and electron microscopes as ground-based applications but also as passive temperature-control devices and optical blocking filters on board mission payload systems as space-based applications.1–3 For example, in the case of X-ray astronomy, instrumental sensitivity for detector and telescope systems is sometimes limited by filter transmission, particularly in the soft energy band below 1 keV. X-rays from astronomical objects, such as black holes, stars, galaxies, and clusters of galaxies, cannot be observed directly from the ground because they are absorbed by the atmosphere of the Earth. For this reason, the observation instruments are mounted on, for example, balloons, rockets, and satellites, to perform observations at altitudes unaffected by the atmospheric absorption. Thus, improvements in the instrumental sensitivity are crucial considering the lifetime of space missions, because soft X-ray observations () are essential for understanding the mysteries of the Universe in a multi-scale structure from stellar systems to galaxies, clusters of galaxies and the large-scale structure of the Universe.4–6 In X-ray astronomy, thin-film devices consist of, for example, a combination of a light metal and polymeric films such as aluminum and polyimide and their supporters to hold the free-standing filter structure.1–3,7,8 The sensitivity of the filter depends on the thickness of the coating material and polymeric films and an open-area ratio basically limited by their physical properties, such as mechanical strength and processing techniques. As for the thickness of the plastic films, it varies from few tens to hundreds of nanometers. Thus, large-area thin filters with higher mechanical strength make it possible to realize high-sensitivity thin-film devices for future astronomical missions. Recently, carbon nanotube (CNT) thin filters with low-energy X-ray transparency, higher mechanical strength, and superior thermal conductance have been proposed for X-ray detectors in space.9 The concept is to utilize superior optical and mechanical properties of CNTs and apply the CNT thin filters in large-area optical blocking filters to protect soft X-ray detectors from the intense optical light of the Sun in astronomical space missions. Bare and aluminum-coated small self-standing pellicles were fabricated successfully, and they exhibited their effectiveness in terms of X-ray transparency quantitatively as a potential innovative material. In this study, as a new approach of replacing polymeric materials with a new material, we explored the possibility of atomically thin graphene to achieve ultimately high X-ray transparency for applications in astronomy. Graphene is also an allotrope of carbon composed of a monolayer of atoms arranged in a hexagonal lattice structure and known to possess outstanding physical properties, such as exceptionally high mechanical strength and electronic and thermal conductivity, which makes it an ideal material for filters. To verify whether graphene sheets can be applicable to thin filters in future space missions, we need to establish fabrication processes to realize possible large-area graphene-based filters that exhibit sufficient tolerance to survive severe space environments. As a first step of a space environmental tolerance evaluation test with applications in astronomy, we focused on tolerance against atomic oxygen (AO). AO is a major component of the atmosphere at altitudes of 200 to 500 km, and mission instruments on board rockets and satellites, particularly in a low Earth orbit (LEO), are sometimes supposed to be exposed to AO directly. In such a situation, AO is known to give rise to a variety of chemical and physical complex reactions with polymeric materials because the AO flow velocity is expected to be corresponding to at an altitude of 500 km.10 Thus, we evaluated the tolerance of uncoated bare graphene for high-speed AO for space applications. In this paper, we report the irradiation test results for single-layer graphene films under high-speed AO irradiation simulating the space environment. Section 2 describes the graphene sample information and the details of the tests, Sec. 3 describes the evaluation method and results, and Sec. 4 summarizes the results. 2.Experimental MethodThis section describes the preparation of the graphene samples and the experimental method employed in high-speed AO irradiation tests. 2.1.SampleThe details of the sample information used in this study are described in this section. We used single-layer graphene (8-mm square) transferred onto a substrate (15-mm square) with a thickness of . The single-layer graphene was formed on a Cu/sapphire substrate through chemical vapor deposition,11 followed by the coating and baking of a polymethyl methacrylate (PMMA) protective film at a temperature of 180°C for 1 min. Thereafter, the following processes were carried out: etching of the Cu/sapphire substrate using ammonium persulfate (0.1 M), pure water rinsing, transferring onto the substrate, and finally removing the PMMA film using acetone. To reduce the PMMA residue, the PMMA removal process was performed at a temperature of 60°C for 30 min. In addition, to prevent erosion from the edges of the graphene sheets and clarify the irradiation area, the sample was irradiated by high-speed AO on an aluminum jig (50 mm square, 6 mm thick) that had a 1-mm-diameter pinhole at the center, as shown in Fig. 1. 2.2.High-Speed AO Irradiation TestsThis section summarizes the experimental setup and conditions for high-speed AO irradiation tests. In this study, we investigated tolerance for high-speed AO in a low-orbit case with an altitude of corresponding to a relative velocity of and a kinetic energy of . To achieve our purposes, a laser-detonation AO beam source at Kobe University12 was used for the high-speed AO irradiation simulations. The expected AO fluence depends strongly on a variety of factors of launch conditions and space environments, such as the location of instruments, the operational altitude of the spacecraft, and a solar activity. For example, in the case of a previous X-ray satellite, (ASTRO-H), the required AO fluence for the thin-film devices consisting of polyimide films was .2 Therefore, an aluminum coating was applied on the polyimide films to impart high tolerance to them to withstand for such a high fluence, as serious damages to the polyimide film following high-speed AO irradiation were reported and expected.13–15 Considering the fact that high-speed AO tolerance for single-layer graphene has not been investigated in detail even though AO adsorption is known to occur on graphene in not so high-speed AO environments,16–18 in this study, we evaluated the behaviors of single-layer graphene by irradiating high-speed AO without a metal coating. Thus, high-speed AO was irradiated with fluence values of , , , , and . The fluence value of corresponds to the minimum value in our experimental setup. The energy distribution during irradiation is estimated by measuring the time of flight (TOF) of ionized high-speed AO using a quadrupolar mass spectrometer located downstream of the high-speed AO beam line. The velocity was converted from the TOF and the averaged velocity was calculated to be . The fluence was determined using the mass loss data of a reference polyimide sample, and the flux was . These tests were conducted under a vacuum level of Pa and almost vertical () AO impact was expected for all of the samples during the irradiation tests.19 The beamline and inside of the sample chamber are shown in Fig. 2. 3.Analysis and ResultsThis section describes the evaluation method of the samples before and after the tests and presents the test results. 3.1.AnalysisTo evaluate the status of single-layer graphene before and after high-speed AO irradiation, we used a Raman spectrometer that is usually employed to evaluate the molecular and crystal structures of carbon materials, such as graphite, CNT, and graphene and a scanning electron microscope (SEM) to observe the surface condition. The Raman spectroscopy measurements were performed using a Renishaw instrument with an exposure time of 3 s, laser power of 5%, and wavelength of 532 nm. Because the laser light is blocked near the edge of the jig aperture, the measurements were performed at the 1 mm center aperture, and their averaged value was adopted for certain points as the initial condition before the tests. Mapping measurements were also performed to estimate an averaged value and a (1-sigma) spatial variation before and after the tests under the identical conditions as described above in the central with a pitch of 6 to . We extracted the G and D band intensities through a fitting procedure, individually assuming a single Gaussian function in each Raman spectrum, and finally focused on a D/G ratio, which is an indicator usually used to quantify the degree of disorderliness and structural defects present in carbon materials. The G band () is the primary mode in graphene caused by a planar molecular motion, whereas the D band is activated by disorderliness and defects. Thus, the ratio increases with decreasing structural quality of the graphene sample. As supplementary data, the intensity of the 2D mode, which also results from the characteristic mode of graphene, was also obtained as in previous studies on carbon materials. The 2D band intensity is also expected to decrease in a decreasing graphene structure. The SEM observations were performed using a JEOL SEM system with a magnification of at 2.00 kV. 3.2.ResultsSome of the typical observed Raman spectra for each high-speed AO irradiation fluence are presented shown in Fig. 3. The observed spectra with fluence values of , , and are very similar to each other, whereas the behavior of the case is found to be different from the others, and no line features are seen for the case. As for the cases with fluence values of , , and , very weak D band intensity was detected, whereas relatively very strong G band intensity was confirmed. In the case, the contrast between the D and G bands becomes much smaller, which suggests that a significant change in terms of the D/G ratio occurs in the fluence values from to . As for the 2D band, emissions were detected except for the case, although the relative intensities of the D and G bands changed drastically. The observed Raman spectra with the best fit models are shown in Fig. 6 of Appendix. Next, we extracted each intensity of each band in each Raman spectrum and found that the D/G ratios before and after the high-speed AO irradiation changed from 0.02 ± 0.01 to 0.02 ± 0.01, 0.03 ± 0.02 to 0.02 ± 0.01, and 0.04 ± 0.03 to 0.05 ± 0.03 for , , and , respectively. Thus, we conclude that there are no significant changes. In contrast, the D/G ratio before and after the high-speed AO irradiation changed from 0.04 ± 0.03 to 0.8 ± 0.4 for drastically in both the averaged value and 1-sigma range. Furthermore, the D/G ratio could not be measured following the high-speed AO irradiation because no peaks were observed in both the G and D bands, which suggests that very few graphene sheets exist following the irradiation. We confirmed that the behavior of the 2D band is similar to that of the G band. The observed D/G ratios are depicted and summarized in Fig. 4 and Table 1, respectively. Consequently, to prevent the single-layer graphene sheets from erosion, a special treatment such as coating is needed to survive in the LEO for a day. Table 1Summary of the D/G ratios for each fluence obtained by Raman spectroscopy before and after the high-speed AO irradiation tests. The ratio is not listed for that fluence because the G and D peaks were not observed after the 2×1019 atoms/cm2 irradiation. The 1-sigma ranges were estimated based on Raman mapping measurements.
Further, as in the case of the Raman spectroscopic results, there is a significant change in the contrast of the SEM images between the irradiated and unirradiated areas following the irradiation. We could not see the difference in contrast up to the fluence value of ; however, a clear contrast could be seen at larger fluence values of and . In particular, in the case of , the contrast of the irradiated area is consistent with that of the substrate area, suggesting that very few graphene sheets exist. The SEM images following the high-speed AO irradiation with fluence values of , , and are presented in Fig. 5. 4.SummaryThin-film devices play a key role in high-energy astrophysics, for example, X-ray astronomy, as passive temperature-control devices and optical blocking filters on board mission payload systems. Polymeric materials such as polyimide have been used, and sometimes thin-film devices limit sensitivity in terms of transmissivity, particularly at the soft X-ray energy range below 1 keV. Thus, we explored the possibility of replacing such polymeric materials with atomically thin graphene to achieve ultimately high X-ray transparency. As a first step, we investigated the tolerance of single-layer uncoated graphene sheets for high-speed AO, expected to be exposed in the LEO. We prepared the single-layer graphene sample and conducted high-speed AO irradiation tests using the laser-detonation AO beam source. We examined the Raman spectral features before and after the tests with fluence values of , , , , and . It was found that the observed D/G ratios before and after the high-speed AO irradiation were from 0.02 ± 0.01 to 0.02 ± 0.01, 0.03 ± 0.02 to 0.02 ± 0.01, and 0.04 ± 0.03 to 0.05 ± 0.03 for , , and , respectively, and we conclude that there are no significant changes. However, the D/G ratios changed from 0.04 ± 0.03 to 0.8 ± 0.4 for drastically in both the averaged value and 1-sigma range. Furthermore, the D/G ratio could not be measured following the high-speed AO irradiation because no peaks were observed in both the G and D bands, which suggests that the degradation occurs between and and very few graphene sheets exist following the irradiation. The SEM images also support this conclusion because there is no significant difference in the image contrast between the irradiated and unirradiated areas up to the case, and no evidence of the existence of the graphene sheets is seen in the case. Consequently, to prevent the single-layer graphene sheets from erosion, a special treatment such as coating is needed to survive in the LEO for a day. The details of the impact of erosion on specific functions such as mechanical strength will be examined in future studies. 5.Appendix: Raman SpectraThe observed Raman spectra with fluence values of , , , and with the best fit models are shown in Fig. 6 of Appendix. Code and Data AvailabilityThe datasets generated and/or analyzed during the current study are available from the corresponding author on reasonable request. AcknowledgmentsThis study was financially supported by Grants-in-Aid for Scientific Research (KAKENHI) of the Japanese Society for the Promotion of Science (JSPS, Grant Nos. JP20K20920, JP22K18274: IM, JP23H05469: RK, JP21H05232, JP21H05233, JP23K17863: HA), Toshiaki Ogasawara Memorial Foundation (IM), Kondo Memorial Foundation (IM), Toyoaki Scholarship Foundation (IM), SCICORP (Grant No. JPMJSC2110: RK), and PRESTO (Grant No. JPMJPR20A2: RK). ReferencesP. J. Serlemitsos et al.,
“The X-ray telescope onboard Suzaku,”
Publ. Astron. Soc. Jpn., 59 S9
–S21 https://doi.org/10.1093/pasj/59.sp1.S9
(2007).
Google Scholar
Y. Tawara et al.,
“Development of ultra-thin thermal shield for ASTRO-H x-ray telescopes,”
Proc. SPIE, 8147 814704 https://doi.org/10.1117/12.893368 PSISDG 0277-786X
(2011).
Google Scholar
M. Barbera, U. Lo Cicero and L. Sciortino,
“Filters for X-ray detectors on space missions,”
(2022). Google Scholar
S. Takasao et al.,
“Investigation of coronal properties of X-ray bright G-dwarf stars based on the solar surface magnetic field-corona relationship,”
Astrophys. J., 901 70 https://doi.org/10.3847/1538-4357/abad34
(2020).
Google Scholar
P. Kaaret et al.,
“A disk-dominated and clumpy circumgalactic medium of the Milky Way seen in X-ray emission,”
Nat. Astron., 4 1072
–1077 https://doi.org/10.1038/s41550-020-01215-w
(2020).
Google Scholar
I. Mitsuishi et al.,
“Search for X-ray emission associated with the shapley supercluster with Suzaku,”
PASJ, 64 18 https://doi.org/10.1093/pasj/64.1.18
(2012).
Google Scholar
P. J. Serlemitsos et al.,
“The X-ray telescope on board ASCA,”
Publ. Astron. Soc. Jpn., 47 105
–114
(1995).
Google Scholar
B. D. Ramsey et al.,
“Optics for the imaging x-ray polarimetry explorer,”
J. Astron. Telesc. Instrum. Syst., 8 024003 https://doi.org/10.1117/1.JATIS.8.2.024003
(2022).
Google Scholar
M. Barbera et al.,
“Carbon nanotubes thin filters for X-ray detectors in space,”
Proc. SPIE, 12181 121814H https://doi.org/10.1117/12.2631516 PSISDG 0277-786X
(2022).
Google Scholar
S. Packirisamy, D. Schwam and M. H. Litt,
“Atomic oxygen resistant coatings for low earth orbit space structures,”
J. Mater. Sci., 30 308
–320 https://doi.org/10.1007/BF00354390 JMTSAS 0022-2461
(1995).
Google Scholar
H. Ago et al.,
“Epitaxial growth and electronic properties of large hexagonal graphene domains on Cu(111) thin film,”
Appl. Phys. Express, 6 075101 https://doi.org/10.7567/APEX.6.075101 APEPC4 1882-0778
(2013).
Google Scholar
M. Tagawa et al.,
“Laser-detonation hyperthermal beam source applicable to VLEO environmental simulations,”
CEAS Space J., 14 757
–765 https://doi.org/10.1007/s12567-021-00399-9
(2022).
Google Scholar
K. Yokota, M. Tagawa and N. Ohmae,
“Temperature dependence in erosion rates of polyimide under hyperthermal atomic oxygen exposures,”
J. Spacecr. Rockets, 40 143
–144 https://doi.org/10.2514/2.3931 JSCRAG 0022-4650
(2003).
Google Scholar
B. A. Banks, K. K. de Groh, S. K. Miller,
“Low earth orbital atomic oxygen interactions with spacecraft materials (Invited Paper),”
Materials for Space Applications, 331 National Aeronautics and Space Administration(
(2005). Google Scholar
W. Zhao et al.,
“Erosion of a polyimide material exposed to simulated atomic oxygen environment,”
Chin. J. Aeronaut., 23
(2), 268
–273 https://doi.org/10.1016/S1000-9361(09)60215-6 CJAEEZ 1000-9361
(2010).
Google Scholar
N. A. Vinogradov et al.,
“Impact of atomic oxygen on the structure of graphene formed on Ir(111) and Pt(111),”
J. Phys. Chem. C, 115
(19), 9568
–9577 https://doi.org/10.1021/jp111962k
(2011).
Google Scholar
M. Z. Hossain et al.,
“Chemically homogeneous and thermally reversible oxidation of epitaxial graphene,”
Nat. Chem., 4 305
–309 https://doi.org/10.1038/nchem.1269 NCAHBB 1755-4330
(2012).
Google Scholar
Ž. Šljivančanin et al.,
“Binding of atomic oxygen on graphene from small epoxy clusters to a fully oxidized surface,”
Carbon, 54 482
–488 https://doi.org/10.1016/j.carbon.2012.12.008 CRBNAH 0008-6223
(2013).
Google Scholar
H. Li et al.,
“Insights into impact interaction between graphene and high-speed atomic oxygen for aerospace protection application,”
Appl. Surf. Sci., 609 155274 https://doi.org/10.1016/j.apsusc.2022.155274 ASUSEE 0169-4332
(2023).
Google Scholar
BiographyIkuyuki Mitsuishi is a lecturer at Nagoya University, Japan. He received his MS degree in 2009 and his PhD in 2012 from the University of Tokyo in physics on the developments of space X-ray optics and studies of astronomical objects, such as stars, the Milky Way Galaxy, starburst galaxies, and galaxy clusters. His current research interests include high angular resolution X-ray optics and thin-film graphene devices, which are widely applied in both ground-based and space instruments and the studies of astronomical objects, such as the Sun, stars, the Milky Way Galaxy, and clusters of galaxies. |