Open Access
1 July 2005 Differences in optical properties between healthy and pathological human colon tissues using a Ti:sapphire laser: an in vitro study using the Monte Carlo inversion technique
Huajiang Wei, Da Xing, Guoyong Wu, Huaimin Gu, Jianjun Lu, Ying Jin, Xiao-Yuan Li
Author Affiliations +
Abstract
The purpose of the study is to analyze and compare differences in the optical properties between normal and adenomatous human colon tissues in vitro at 630-, 680-, 720-, 780-, 850-, and 890-nm wavelengths using a Ti:sapphire laser. The optical parameters of tissue samples are determined using a double integrating sphere setup at seven different laser wavelengths. The inverse Monte Carlo simulation is used to determine the optical properties from the measurements. The results of measurement show that the optical properties and their differences vary with a change of laser wavelength for normal and adenomatous colon mucosa/submucosa and normal and adenomatous colon muscle layer/chorion. The maximum absorption coefficients for normal and adenomatous human colon mucosa/submucosa are 680 nm, and the minimum absorption coefficients for both are 890 nm. The maximum difference of the absorption coefficients between both is 56.8% at 780 nm. The maximum scattering coefficients for normal and adenomatous colon mucosa/submucosa are 890 nm, and the minimum scattering coefficients for both are 780 nm. The maximum difference of the scattering coefficients between both is 10.6% at 780 nm. The maximum absorption coefficients for normal and adenomatous colon muscle layer/chorion are 680 nm, and the minimum absorption coefficients for both are 890 nm. The maximum difference of the absorption coefficients between both is 47.9% at 780 nm. The maximum scattering coefficients for normal and adenomatous colon muscle layer/chorion are 890 nm, and the minimum scattering coefficients for both are 680 nm. The maximum difference of the scattering coefficients between both is 9.61% at 850 nm. The differences in absorption coefficients between normal and adenomatous tissues are more significant than those in scattering coefficients.
©(2005) Society of Photo-Optical Instrumentation Engineers (SPIE)
Huajiang Wei, Da Xing, Guoyong Wu, Huaimin Gu, Jianjun Lu, Ying Jin, and Xiao-Yuan Li "Differences in optical properties between healthy and pathological human colon tissues using a Ti:sapphire laser: an in vitro study using the Monte Carlo inversion technique," Journal of Biomedical Optics 10(4), 044022 (1 July 2005). https://doi.org/10.1117/1.1990125
Published: 1 July 2005
Lens.org Logo
CITATIONS
Cited by 28 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Colon

Absorption

Tissues

Scattering

Optical properties

Laser scattering

Monte Carlo methods

Back to Top