6 September 2012 Noninvasive Raman spectroscopy of rat tibiae: approach to in vivo assessment of bone quality
Paul I. Okagbare, Michael D. Morris, Dana Begun, Steven A. Goldstein, Mary Tecklenburg
Author Affiliations +
Funded by: National Institutes of Health (NIH)
Abstract
We report on in vivo noninvasive Raman spectroscopy of rat tibiae using robust fiber-optic Raman probes and holders designed for transcutaneous Raman measurements in small animals. The configuration allows placement of multiple fibers around a rat leg, maintaining contact with the skin. Bone Raman data are presented for three regions of the rat tibia diaphysis with different thicknesses of overlying soft tissue. The ability to perform in vivo noninvasive Raman measurement and evaluation of subtle changes in bone composition is demonstrated with rat leg phantoms in which the tibia has carbonated hydroxylapatite, with different carbonate contents. Our data provide proof of the principle that small changes in bone composition can be monitored through soft tissue at anatomical sites of interest in biomedical studies.

1.

Introduction

Bone undergoes continuous remodeling in response to loading, local damage, and pathologies. Remodeling of bone changes its chemical composition, which is an important indicator of its physiological status and mechanical competence.1,2 The ability to measure changes in chemical composition of bone is, therefore, important.24 Existing noninvasive technologies used to monitor bone evaluate the morphology and calcium content, but provide no direct information on other properties of the tissue.59 Vibrational spectroscopy has proved useful in the study of bone development, bone biomechanics, and bone pathologies because it provides this composition information.10,11 Unlike infrared spectroscopy, which provides essentially similar information, Raman spectroscopy suffers little from water interference; therefore, it is applicable to fresh tissue and in vivo measurements.12

However, in vivo Raman spectroscopy has its own challenges, including background fluorescence from tissue components (especially skin melanin), interfering protein spectral bands from overlying soft tissue, and the multiple scattering that is characteristic of almost all tissues.13 These challenges limit the depth from which Raman signals can be collected.

Realizing the potential for in vivo studies requires fiber-optic probes that are configured for transcutaneous Raman measurement on a time scale ranging from a few seconds to one or 2 min. Our laboratory has developed several fiber-optic probes based on spatial separation of excitation and collection fibers that allow bone Raman spectroscopy through layers of overlying tissue.14,15 The principle is well known in tissue spectroscopy; in the literature, it is called spatially offset Raman spectroscopy.16,17 A limitation of spatial offsetting is that measurement time increases rapidly as the depth of penetration increases. We have previously demonstrated backscattering in in vivo collection of murine Raman spectra at depths of a few millimeters in mice18 and low-definition Raman tomography in excised tissue at thicknesses of more than 2 cm.19 These measurements have required unrealistically long times. Here, we describe and test a probe configuration adapted from diffuse optical tomography that reduces measurement time to 60 s at several positions along a rat tibia.

We have previously reported cadaveric rat tibia studies using a diffuse tomography-based probe containing 50 collection fibers terminated in stainless steel ferrules and a single excitation fiber that could be positioned at one of several points around the tibia.20 The fibers were mounted in a conformal silicone holder.

In the present design, the fifty 100-µm silica core fibers are grouped into 10 bundles of five fibers each, providing greater mechanical robustness. A single 300-µm silica core excitation fiber is used. A demountable aluminum fiber holder that can be positioned reproducibly around the leg of the rat replaces the silicone holder used previously (Fig. 1).20 The fiber holder is constructed as two pieces to facilitate rapid placement and removal. O-rings mounted through holes arranged around the circumference of the holder allow the easy insertion and removal of fibers. The design allows a sequence of measurements with the excitation fiber placed at a different position in each measurement to optimize the collection of bone spectra. The aluminum holder is easily positioned at different points along the tibial diaphysis. The placement of the illumination and collection probes generates adequate spatial offset for transcutaneous Raman measurement on rat limbs. The collection fibers are arranged into a linear array for coupling to the input slit of a Raman spectrograph. The Raman instrument is an axial transmissive Raman spectrograph equipped with an 830-nm excitation laser and a 256×1024 front-illuminated CCD for collection of near-infrared light (RamanRxn1, Kaiser Optical Systems Inc., Ann Arbor, MI).

Fig. 1

Noninvasive Raman spectroscopy of a rat tibia. (a) The probe holder is fastened to a bed on which the rat lies while anesthetized. The fibers (D1–D9) are adjustable, as shown with a phantom. (b) The phantom mimics the anatomy and spectroscopy of rat leg. (c) A rat leg rendering showing the three regions along the diaphysis where Raman spectra were obtained.

JBO_17_9_090502_f001.png

Using this probe and a holder with single-fiber illumination, bone Raman spectra were acquired for 60 s at three regions along the diaphysis of the tibia of an anesthetized rat, as shown in Fig. 1(c). This sequence allowed measurement through different thicknesses of overlying soft tissue. The acquired Raman data were processed in MATLAB (MathWorks, Inc., Natick, MA) as previously described to remove cosmic ray spikes, grating-induced curvature, and grating/detector misalignment.20,21 The spectra are reported as wavenumber shifts and are corrected for detector quantum efficiency variation after background subtraction (tissue autofluorescence removal).20,22 Figure 2(a) presents unsmoothed Raman spectra from the three diaphysial positions without any removal of overlying tissue contributions. As expected, the intensity of the bone mineral band at 960cm1 relative to collagen protein bands at 1450 and 1660cm1 is greater for region 1 (960/1660=3.06), where the maximum thickness of the overlying soft tissue is about 1 mm. There are increasing contributions from the overlying tissue signal in regions 2 and 3 [0.5cm (960/1,660=1.94) and 1cm (960/1660=1.57) maximum thickness, respectively]. In every case, one or more detectors (fibers) views bone underneath a thin layer of tissue due to the anatomy of the rat leg, so mineral/collagen intensities do not scale linearly with the maximum soft tissue thickness. For example, in region 3, detector fiber 1 is located over the tibia with 5mm of soft tissue thickness from the underlying bone, while detectors 2, 3, 4, and 5, and 6, 7, 8, and 9 are more than 8.5mm and 14.1mm, respectively, from the underlying bone. In region 2, fiber 1 is positioned at 3mm, fibers 2, 3, 4, and 5 at 4.6mm and fibers 6, 7, 8, and 9 at 7mm from the bone. In region 1, all fibers are positioned with approximately the same soft tissue separation (1mm) from the underlying bone. The variation in acquired bone mineral Raman signal intensities relative to each individual fiber position is shown in Fig. 2(b) for region 2.

Fig. 2

Raman spectra from three different regions of rat leg along the tibial diaphysis. Spectra were normalized to the protein band at 1660cm1. (b) Raman spectra from the individual fibers labeled D1–D9 in the wavelength range of 850 to 1100cm1. The intensities of the phosphate (bone mineral) band varied with fiber positions. (c) Recovered bone Raman spectra after BTEM was performed on the data in (a) for the three regions. Soft tissue contributions are minimized to recover the bone Raman spectrum. Spectra were normalized to the mineral band at 960cm1.

JBO_17_9_090502_f002.png

Overlying tissue contributions cause changes in the relative intensities of the protein bands with respect to the mineral band. To separate the bone Raman spectrum from soft tissue contribution, band target entropy minimization (BTEM)23 was performed on the spectra from the three regions using the first few eigenvectors of the singular value decomposition (SVD) matrix.18 The unsmoothed recovered spectra for the three regions are shown in Fig. 2(c). Soft tissue contributions to the spectra are minimized, but not completely removed, after BTEM and the intensities of the bone mineral band at 960cm1 relative to collagen protein bands are enhanced in regions 2 and 3. The incomplete removal of soft tissue by BTEM could be associated with the short acquisition time, the signal-to-noise ratio, and the limited number of input spectra into the BTEM algorithm. These results suggest that this probe configuration is suitable for longitudinal spectroscopic studies of fracture healing, among other subjects. The probe can be positioned in 1-min measurements made in 1 min, and the probe removed in a few seconds. in vivo Raman spectroscopy can consume a small fraction of the 30-min maximum duration of anesthesia.

Carbonate substitution is one of the proposed Raman metrics for evaluating bone quality.3 Because of the proximity of CO32ν1 to a component of PO43ν3 it is notoriously difficult to measure band intensity accurately.24 We demonstrated the ability to measure small changes in bone compositions using multilayer phantoms that model geometric, optical, and spectroscopic rat leg properties.20,25 The phantoms were constructed with carbonated hydroxyapatite containing different amounts of carbonate as the bone mineral model.20,25 Raman spectra of the phantoms were acquired at the laser powers and measurement times used for the rat tibia. The resulting Raman spectra are shown in Fig. 3. The band intensities at 1070cm1 for the 0.3%, 4.7% and 6.9% CO32 values increase with increasing carbonate substitution. The width of PO43ν1 at 960cm also increases with increasing carbonate substitution and shifts to lower wavenumber (see Fig. 3 insert), as reported for the salts.24 The full-width half-maximum of the PO43ν1 band scales linearly (r2=0.99) with CO32 content (the linear plot is not shown in Fig. 3). These data provide proof of the principle that small changes in bone composition can be monitored through at least a 1-cm layer of soft tissue.

Fig. 3

Transcutaneous Raman spectra acquired from rat leg. The rat leg models were constructed using carbonated hydroxyapatite with varied level of carbonate substitution (0.3%, 4.7%, and 6.9% carbonated hydroxyapatite) as the tibia model. Differences between specimens were captured in the Raman spectra. Intensity of the carbonate band at 1070cm1 and the width of the phosphate band at 960cm1 both increase with carbonate substitution. The expanded view of the spectra in (a) showing the wavenumber range from 930 to 980cm1 is presented as an insert. The position of the PO43ν1 peak shifted from 960 to 958cm1 with increasing carbonate substitution.

JBO_17_9_090502_f003.png

Our results complement the results of our previous report on the distal tibiae of mice, which have a thinner layer of soft tissue.18 Although we have not directly addressed noninvasive human subject bone spectroscopy, our results suggest that at some sites, 1-min measurements are feasible.

Acknowledgments

The authors acknowledge support of this work through National Institutes of Health (NIH) Grants R01AR055222 and R01AR056646. The authors also thank Kathleen Sweet for help with animal handling and Charles Roehm for construction of the optical fiber holder.

References

1. 

X. FengJ. M. McDonald, “Disorders of Bone Remodeling,” Ann. Rev., 121 –145 Palo Alto (2011). Google Scholar

2. 

S. Gamsjägeret al., “Raman application in bone imaging,” Raman Spectroscopy for Soft Matter Applications, 225 –267 John Wiley & Sons, Inc., Hoboken, New Jersey (2009). Google Scholar

3. 

M. Morris, “Raman spectroscopy of bone and cartilage,” Emerging Raman Applications and Techniques in Biomedical and Pharmaceutical Fields, 347 –364 Springer, Berlin Heidelberg (2010). Google Scholar

4. 

J. R. Maheret al., “Raman spectroscopy detects deterioration in biomechanical properties of bone in a glucocorticoid-treated mouse model of rheumatoid arthritis,” J. Biomed. Opt., 16 (8), 087012 (2011). http://dx.doi.org/10.1117/1.3613933 JBOPFO 1083-3668 Google Scholar

5. 

M. L. Brandi, “Micro architecture, the key to bone quality,” Rheum., 48 IV3 –IV8 (2009). http://dx.doi.org/10.1093/rheumatology/kep273 RHEUBD 0080-2727 Google Scholar

6. 

O. D. KennedyF. J. O’Brien, Bone Quality: Where Should We Be Looking?, Nova Science Publishers, Inc., Hauppauge, NY (2009). Google Scholar

7. 

H. K. GenantK. EngelkeS. Prevrhal, “Advanced CT bone imaging in osteoporosis,” Rheumatology, 47 9 –16 (2008). http://dx.doi.org/10.1093/rheumatology/ken180 RHEUBD 0080-2727 Google Scholar

8. 

T. M. Link, “Osteoporosis imaging: state of the art and advanced imaging,” Radiology, 263 (1), 3 –17 (2012). http://dx.doi.org/10.1148/radiol.12110462 RADLAX 0033-8419 Google Scholar

9. 

T. VokesM. Favus, “Noninvasive assessment of bone structure,” Curr. Osteo. Rep., 1 (1), 20 –24 (2003). http://dx.doi.org/10.1007/s11914-003-0004-9 1544-1873 Google Scholar

10. 

E. Donnelly, “Methods for assessing bone quality: a review,” Clin. Orthop. Rel. Res., 469 (8), 2128 –2138 (2011). http://dx.doi.org/10.1007/s11999-010-1702-0 CORTBR 0009-921X Google Scholar

11. 

A. L. BoskeyR. Mendelsohn, “Infrared spectroscopic characterization of mineralized tissues,” Vib. Spectrosc., 38 (1–2), 107 –114 (2005). http://dx.doi.org/10.1016/j.vibspec.2005.02.015 VISPEK 0924-2031 Google Scholar

12. 

M. D. MorrisG. S. Mandair, “Raman assessment of bone quality,” Clin. Orthop. Rel. Res., 469 (8), 2160 –2169 (2011). http://dx.doi.org/10.1007/s11999-010-1692-y CORTBR 0009-921X Google Scholar

13. 

M. V. Schulmerichet al., “Optical clearing in transcutaneous Raman spectroscopy of murine cortical bone tissue,” J. Biomed. Opt., 13 (2), 021108 (2008). http://dx.doi.org/10.1117/1.2892687 JBOPFO 1083-3668 Google Scholar

14. 

M. V. Schulmerichet al., “Transcutaneous fiber optic Raman spectroscopy of bone using annular illumination and a circular array of collection fibers,” J. Biomed. Opt., 11 (6), 060502 (2006). http://dx.doi.org/10.1117/1.2400233 JBOPFO 1083-3668 Google Scholar

15. 

M. V. Schulmerichet al., “Subsurface and transcutaneous Raman spectroscopy and mapping using concentric illumination rings and collection with a circular fiber-optic array,” Appl. Spectrosc., 61 (7), 671 –678 (2007). http://dx.doi.org/10.1366/000370207781393307 APSPA4 0003-7028 Google Scholar

16. 

P. Matouseket al., “Subsurface probing in diffusely scattering media using spatially offset Raman spectroscopy,” Appl. Spectrosc., 59 (4), 393 –400 (2005). http://dx.doi.org/10.1366/0003702053641450 APSPA4 0003-7028 Google Scholar

17. 

P. Matousek, “Inverse spatially offset Raman spectroscopy for deep noninvasive probing of turbid media,” Appl. Spectrosc., 60 (11), 1341 –1347 (2006). http://dx.doi.org/10.1366/000370206778999102 APSPA4 0003-7028 Google Scholar

18. 

M. V. Schulmerichet al., “Transcutaneous Raman spectroscopy of murine bone in vivo,” Appl. Spectrosc., 63 (3), 286 –295 (2009). http://dx.doi.org/10.1366/000370209787599013 APSPA4 0003-7028 Google Scholar

19. 

M. V. Schulmerichet al., “Noninvasive Raman tomographic imaging of canine bone tissue,” J. Biomed. Opt., 13 (2), 020506 (2008). http://dx.doi.org/10.1117/1.2904940 JBOPFO 1083-3668 Google Scholar

20. 

P. I. Okagbareet al., “Development of non-invasive Raman spectroscopy for in vivo evaluation of bone graft osseointegration in a rat model,” Analyst, 135 (12), 3142 –3146 (2010). http://dx.doi.org/10.1039/c0an00566e ANLYAG 0365-4885 Google Scholar

21. 

F. W. Esmonde-WhiteK. A. Esmonde-WhiteM. D. Morris, “Minor distortions with major consequences: correcting distortions in imaging spectrographs,” Appl. Spectrosc., 65 (1), 85 –98 (2011). http://dx.doi.org/10.1366/10-06040 APSPA4 0003-7028 Google Scholar

22. 

C. A. LieberA. Mahadevan-Jansen, “Automated method for subtraction of fluorescence from biological Raman spectra,” Appl. Spectrosc., 57 (11), 1363 –1367 (2003). http://dx.doi.org/10.1366/000370203322554518 APSPA4 0003-7028 Google Scholar

23. 

E. Widjajaet al., “Band-target entropy minimization (BTEM) applied to hyperspectral Raman image data,” Appl. Spectrosc., 57 (11), 1353 –1362 (2003). http://dx.doi.org/10.1366/000370203322554509 APSPA4 0003-7028 Google Scholar

24. 

A. AwonusiM. D. MorrisM. M. J. Tecklenburg, “Carbonate assignment and calibration in the raman spectrum of apatite,” Calcif. Tissue Int., 81 (1), 46 –52 (2007). http://dx.doi.org/10.1007/s00223-007-9034-0 CTINDZ 0171-967X Google Scholar

25. 

F. W. L. Esmonde-Whiteet al., “Biomedical tissue phantoms with controlled geometric and optical properties for Raman spectroscopy and tomography,” Analyst, 136 (21), 4437 –4446 (2011). http://dx.doi.org/10.1039/c1an15429j ANLYAG 0365-4885 Google Scholar
© 2012 Society of Photo-Optical Instrumentation Engineers (SPIE) 0091-3286/2012/$25.00 © 2012 SPIE
Paul I. Okagbare, Michael D. Morris, Dana Begun, Steven A. Goldstein, and Mary Tecklenburg "Noninvasive Raman spectroscopy of rat tibiae: approach to in vivo assessment of bone quality," Journal of Biomedical Optics 17(9), 090502 (6 September 2012). https://doi.org/10.1117/1.JBO.17.9.090502
Published: 6 September 2012
Lens.org Logo
CITATIONS
Cited by 38 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Raman spectroscopy

Bone

Optical fibers

Tissues

In vivo imaging

Carbonates

Tissue optics

Back to Top