Noninvasive, three-dimensional, and longitudinal imaging of cerebral blood flow (CBF) in small animal models and ultimately in humans has implications for fundamental research and clinical applications. It enables the study of phenomena such as brain development and learning and the effects of pathologies, with a clear vision for translation to humans. Speckle contrast optical tomography (SCOT) is an emerging optical method that aims to achieve this goal by directly measuring three-dimensional blood flow maps in deep tissue with a relatively inexpensive and simple system. High-density SCOT is developed to follow CBF changes in response to somatosensory cortex stimulation. Measurements are carried out through the intact skull on the rat brain. SCOT is able to follow individual trials in each brain hemisphere, where signal averaging resulted in comparable, cortical images to those of functional magnetic resonance images in spatial extent, location, and depth. Sham stimuli are utilized to demonstrate that the observed response is indeed due to local changes in the brain induced by forepaw stimulation. In developing and demonstrating the method, algorithms and analysis methods are developed. The results pave the way for longitudinal, nondestructive imaging in preclinical rodent models that can readily be translated to the human brain. |
1.IntroductionMicrovascular cerebral blood flow (CBF) dynamics is an important biomarker of healthy brain development, pathology, and injury since it is a measure of the delivery of nutrients necessary for tissue metabolism and of the clearance of the by-products. The coupling between the neuronal activity and regional CBF is regarded as fundamental in the study of functional brain activity and is the basis of many functional neuroimaging techniques.1,2 For example, it is responsible for the blood oxygen level-dependent (BOLD) signal that is commonly employed in functional magnetic resonance imaging (fMRI). Wide-field superficial3 and deep tissue () diffuse optical4–6 methods provide similar contrasts, and in comparison to large imaging modalities, their advantages are portability, fast and continuous monitoring, the use of nonionizing radiation, and being noninvasive. The main contrast to optical methods has traditionally been that of the oxy- and deoxy-hemoglobin concentration7,8 but various methods utilizing laser speckle statistics have allowed for the direct measurement of blood flow.9–11 Most common optical techniques for blood flow monitoring are based on the dynamic scattering of light and include laser Doppler flowmetry,12,13 laser speckle contrast imaging,9,11 and diffuse correlation spectroscopy (DCS).14 Of these methods, DCS uses long-coherence laser light with point sources and displaced point detectors to measure the temporal fluctuations of a diffuse speckle which is translated into a blood flow index (BFI) from the deep tissues using model-based algorithms.10 DCS is very attractive for CBF monitoring because its sensitivity can reach up to several centimeters. However, it also has several disadvantages, such as sophisticated hardware requirements and the associated lack of scalability thus reducing the spatial resolution and the ability to localize the signals. This is mainly because the high-density source–detector arrangements involving parallel acquisition from many source–detector pairs over a large range of separations are needed to achieve better resolution and location. This was, in fact, crucial to the success of diffuse optical tomography (DOT).15–17 This is not, so far, accessible for diffuse correlation tomography (DCT).18–20 To date, DCT has been limited to pilot studies on small animals18,19 and coarse measurements on humans.20 Recently, speckle contrast optical spectroscopy/tomography (SCOS/SCOT) was introduced to overcome some of these limitations.21–24 It combines single-point illumination with a two-dimensional detector array to probe deep tissues. This method has successfully been used to monitor relative cerebral blood flow (rCBF) due to changes in a functional task in the adult human brain.25 SCOT can achieve scalability using the speckle contrast with an appropriate correlation diffusion model to relax the requirement, which the data-type used by DCT has, i.e., relatively fast (tens of nanoseconds) output from the detectors, thus allowing for readily available detector arrays to be utilized in the measurements.25–28 Here we highlight speckle contrast optical tomography (SCOT) which, by taking advantage of the scalability of SCOS detection, achieves tomographic measurements using scanning sources and array detectors.27,28 Our recent developments in mice revealed comparable results to magnetic resonance imaging in following the infarct induced by CBF reduction.27 A similar development29 has been successfully used in the intraoperative room, where the three-dimensional (3-D) distribution of blood flow from a mastectomy skin flap was resolved. These applications highlight the potential of tomographic speckle contrast imaging in the clinic and in biomedical research. However, these examples are either too slow or use a too sparse array of detectors/sources to push the technique to its full potential. On the other hand, traditional DOT has been pushed closer to its full potential by the introduction of high density (HD-DOT) and fast scanning.15,17,30 HD-DOT allows increased spatial resolution and improves the accuracy of the detected changes by utilizing many, densely spaced overlapping samples of the probed tissue volume. By being fast, it also allows for the monitoring of the evolution of the functional changes and the regression of the confounding systemic signals. HD-DOT was shown to approach the resolution and accuracy of BOLD-fMRI in the adult brain.31 However, HD-DOT measures the change in concentration of oxy- and deoxy-hemoglobin during functional activation in small animals and humans15,30,32 without retrieving CBF information. In HD-DOT, CBF information can be inferred by the use of specific challenges or contrast agents, thus making the measurements complex. Given the above developments, the stage is now set for the introduction of fast, high-density SCOT (HD-SCOT) to achieve high-density 3-D blood flow imaging. The first step toward that end is to apply HD-SCOT in the rat brain, transcranially, without thinning the skull. This is motivated by the considerable interest in small animal imaging, since they allow the investigation of neurovascular coupling in the normal brain, during the progression of diseases (e.g., Alzheimer’s) or severe pathological events (e.g., stroke). Furthermore, HD-SCOT would allow to follow up on the effects of therapeutic drugs, the evolution of treatment and the recovery of brain function33 over longer time periods (months to years). The measurement of the same parameter was considered by DCS in longitudinal monitoring of rodents,34 demonstrating that the growth of the animal can impact the measurements in a detrimental manner unless a large field-of-view (FOV) measurement with tomographic reconstruction is achieved. In other words, both the magnitude and the location of the signal changes over time in a rapidly aging small animal model. In this study, we have developed and demonstrated the capabilities of SCOT for the monitoring of the cerebral blood flow response due to functional forepaw stimulation-induced changes in the somatosensory cortex of the rat brain. Tomographic images with good spatial resolution were possible due to the availability of high-density data. Furthermore, in order to increase the temporal resolution, we have introduced a technique based on a moving window scheme, which effectively improves the sampling efficiency. 2.Materials and Methods2.1.Animal PreparationThe experimental protocol was approved by the ethical committee of the University of Barcelona. Adult male Wistar rats () were anesthetized with 4% isoflurane and moved to a stereotaxic frame. The anesthesia was reduced to 2% isoflurane and the surgical procedure was performed, that consisted of the retraction of the skin and underlying muscle while keeping the skull intact, to avoid confounding effects. We note that this is not a necessary condition for the method and it could be applied fully noninvasively.35 A well surrounding the imaging area was built with dental cement and was filled with mineral oil to prevent the skull from drying out. After surgery, the isoflurane infusion was stopped and anesthesia was maintained with a continuous intravenous administration of -chloralose (). 2.2.Functional Activation ParadigmElectrical stimulation was achieved with a pair of subdermal needle electrodes that were inserted into right and left forepaws. The experiment consisted of electrically stimulating each forepaw individually with pulses at 6-Hz repetition rate and an amplitude of 2 mA. The stimulation paradigm comprised of 18-s baseline, 30-s electrical stimulation, and 90-s recovery. This was repeated eight times for each forepaw.16 Once the functional protocol was completed, four repetitions of sham measurements were taken for the same duration, during which no electrical stimulation was performed, but the subdermal needles were kept inside forepaws. 2.3.Magnetic Resonance ImagingTo compare SCOT, functional MRI was acquired for the same animals () under -chloralose () anesthesia within 24 to 72 h after optical data were acquired. Experiments were conducted in a 7T MRI magnet (Bruker BioSpin, Germany). Coronal multislice spin-echo echo-planar images were acquired with a repetition time (TR) of 3 s and a bandwidth of 150 kHz. In total, five slices with 2-mm thickness were acquired with an FOV of and a pixel size of . Additionally, anatomical high-resolution T2-weighted images were obtained to align the fMRI and SCOT reconstructions (see Sec. 2.6). Anatomical data consisted of forty slices with 0.08-mm thickness, FOV of , and pixel size . 2.4.Speckle Contrast Optical Tomography InstrumentationThe instrumentation was described in a previous publication27 and we review it in brief. The main components of the SCOT system are displayed in Fig. 1(a), where the scanning module consisted of a temperature-controlled continuous-wave laser at 785 nm (Thorlabs, Germany) that was focused by aspheric lenses onto a pair of galvo-mirrors (Nutfield), which were directing the light beam onto the rat head.27 The reflected diffuse light was captured by a CCD camera (Basler, Germany, scA640-120 fm). 2.5.Optical Data Acquisition ProtocolOnce the surgery was completed, the rat was moved under the imaging arm of the setup as shown in Fig. 1(a). During the alignment of the imaging domain, the central source of the array was adjusted to coincide with the location of a Bregma point [Fig. 1(b)]. The number of source positions was fixed at nine for all animals organized in a arrays [Fig. 1(b)]. A calibration image was then taken where the physical imaged area per pixel was calibrated using a ruler placed on top of the rat’s head. The -number of the optical system was chosen to match the pixel to speckle size. Then the dental cement well was filled with mineral oil. Additionally, a green light LED (525 nm) was used to illuminate the rat’s head and verify that the imaging area was free of contaminants (i.e., hair and bubbles). Otherwise, the mineral oil was withdrawn, the head was cleaned, and the oil was reapplied. Furthermore, to obtain the baseline blood flow, 20 exposure times that were logarithmically spaced between and 10 ms were used to recover the baseline CBF. Then the stimulation protocol (Sec. 2.2) was conducted while SCOT data were being acquired. Images were acquired with an exposure time of 1 ms and an FOV of . One full tomographic data set consisted of the acquisition of a 100 images per source location, which was completed in 6 s. Calculation of the speckle contrast was done in the temporal approach.36 In the end, to account for the variance of the sensor dark noise, 900 images with an exposure time of 1 ms were collected with the laser light off. 2.6.Theory and Algorithms2.6.1.Theory of speckle contrastThe speckle contrast squared is defined as the ratio of the variance to the squared mean value of the intensity as where is the exposure time and is the source–detector separation. The mean and the variance can be computed either temporally (over independent speckles in a single pixel over time) or spatially (over independent speckles in different, neighboring pixels).36,37 Furthermore, the speckle contrast can be related to the normalized electric field autocorrelation function by where is the correlation delay time, and is an optical system parameter proportional to the number modes/speckles in the detection system, which is for unpolarized light used in this study. This equation is related to the optical parameters of the medium and BFI through modeling of the function using the correlation diffusion equation. 10 These methods were previously validated for SCOS/SCOT in phantoms, small animal models and adult, human subjects.21,282.6.2.Speckle contrast correction and data analysisPrior to the solution of the inverse problem for the tomographic reconstruction, the speckle contrast was corrected to account for the shot and dark noise variations associated with the camera sensor. The corrected speckle contrast is defined as20 where is the dark corrected intensity, and are the mean and variance of the dark noise over a number of frames, and denotes the variance of the estimated shot noise. In addition, to improve the signal-to-noise ratio (SNR) and to reduce the computational load, the speckle contrast of four adjacent pixels was binned into a single pixel [Fig. 2(b)].27The baseline BFI was determined using multi-exposure speckle imaging (MESI),26,38 using the multi-exposure data that was acquired as described in Sec. 2.5 and Ref. 37. The MESI, together with Eq. (2), was used to fit for an averaged using the dependence of the speckle contrast on the exposure time as previously described for SCOS.21,25,26 Valid source–detector pairs were selected based on two criteria, where first was that source–detector pairs with separations shorter than 0.15 cm were disregarded since the diffusion model fails to predict the transport of photon at short separations,39 also, pixels near the source illumination point were discarded since they were saturated. In the future, a higher order approximation to the radiation transport equation can be used to retain all the nonsaturated data. Second, source–detector pairs with a separation larger than 0.65 cm were discarded to avoid contamination or biasing of the signals due to the limited FOV, where many detectors were reaching the dental cement surrounding well and the lower SNR. 2.6.3.Reconstruction of blood flow index changesDifferential images of the BFI were obtained using the first Born approximation of Eq. (2)28 at each time point. This is represented by where is the Jacobian, is the baseline (Sec. 2.6.4), corrected speckle contrast squared, and is the corrected speckle contrast squared that was altered due to a perturbation. Under this approximation, the temporal changes in the measured speckle contrast are linearly related to spatial variations in the BFI () in a 3-D space. The tomographic image of these values can be obtained by inverting the above relationship. Since the inversion process is an ill-posed problem, we have regularized the inversion using a spatially varying Tikhonov regularization scheme.27,28,40An illustration of the imaging domain is displayed in Fig. 2(a), which consisted of 5,280 voxels (). A sample image of the input measurement data is shown in Fig. 2(b) together with the source locations (red circles) and the voxel positions. 2.6.4.Time series of relative cerebral blood flowBaseline data () were defined as the mean of the corrected speckle contrast during the first 18 s. The time series of changes in the corrected speckle contrast from the baseline (), i.e., , were inverted to obtain temporal changes of cerebral blood flow, i.e., . The results are presented as relative temporal changes of CBF , which is defined as the ratio of to the baseline BFI ():27 To quantify the spatial extent of the activation at the depth with the largest change, the area of activation was defined as the number of pixels with rCBF of the maximum response.11 Additionally, the recovered images were compared to the MRI data by co-registering the anatomical MRI and optical images using the Bregma point as a reference. Then optical data were transformed into the MRI coordinates taking the curvature of the brain into account for better visualization.27 2.6.5.Sliding tomographic reconstruction scheme to improve the temporal resolutionThe standard reconstruction scheme, described in Fig. 3(a), involves solving the inverse problem once a full tomographic data set is available, i.e., after all sources have completed a scanning cycle. Then the process is repeated for subsequent scanning cycles. One disadvantage of this method is that rapidly evolving changes, such as those during somatosensory activation, of the signals are averaged over due to having a tomographic image every few seconds. Here a reconstruction scheme based on a moving window was employed to improve the temporal resolution. It is similar to the jittering of the RT used in fMRI to improve the efficiency of the sampling.41 The process is displayed in Fig. 3(b), where a tomographic image can be obtained as soon as data from a new source position is available. This is possible on the basis that the reference source can be arbitrarily assigned and the necessary conditions for the inversion are fulfilled as long as data from every source is available [Fig. 3(b)]. Furthermore, since the time delay for switching between scanning positions is considerably smaller than the acquisition time, i.e., the scanning process can be considered continuous regardless of the selection of the source as a reference. The method does not produce independent samples, but rather a running average thus the reconstructions include data across different stages, Fig. 3(c) (dotted circles). In Fig. 3(c), the dense imaging achieved by the sliding window reconstruction scheme (void circles) is compared with the sparse temporal imaging obtained with the standard approach (filled circles). Since the “contamination” from samples, i.e., source positions, from different stages introduce artifacts due to the averaging of data at different conditions, we have also defined a period of influence to indicate the time points were the contribution of data from the stimulation stage is . This period of influence is illustrated with the shaded regions before and after the stimulation stage in Fig. 3(c). 3.Results3.1.Data Conditioning ResultsBefore image reconstruction, the usable source–detector pairs needed to be identified as described in Sec. 2.6.2. As Fig. 4(a) shows, the speckle contrast data from source one, which displays several features including the location of the source, large vessels and the effect of the dental cement. In particular, the speckle contrast along the horizontal red line is plotted in Fig. 4(b), where the effect of the source is visible. As described in Sec. 2.6.2, only source–detector pairs with separations in the range of 0.15 to 0.65 cm were kept before proceeding to the inversion process. On average, considering the nine sources, a total of valid source–detector pairs were used for image reconstruction for each animal. 3.2.Differential Data and Image ReconstructionFigure 5(a) depicts a sample of the differential speckle contrast () during the stimulation stage from the source indicated with the red circle while the remaining source locations are shown in white. Particularly, there is a region indicated with the colored squares that shows a reduction of the speckle contrast during the stimulation stage. The relative temporal changes of with respect to baseline () at these locations are displayed in Fig. 5(b). A decrease of the speckle contrast during the stimulation can be observed followed by a return to the baseline. In other words, as expected, these changes reveal an increase of the CBF during the stimulation stage. Figure 6(a) shows representative volumetric images of rCBF during left forepaw stimulation. Each column corresponds to different time points, whereas rows indicate slices in depth. The first column during the baseline period shows maps that are relatively homogeneous. However, during the stimulation stage, an active region at with higher is distinguishably followed by maps similar to those at baseline. The locations of apparent changes of at the skull level () are due to the regularization operation which produces smooth responses rather than sharp changes. The time course of the activation region () centered at the peak value, displayed in Fig. 6(b), demonstrates the increased blood flow during the stimulation stage. The onset of the increase of before the start of the stimulation is an artifact produced by the sliding average effect, which covers data within the baseline and activation periods as described above. 3.3.Comparison to Functional Magnetic Resonance ImagingThe registration of the MRI and the optical data allowed a direct comparison of the location and the spatial extent of the activation. Figures 7(a) and 7(b) show representative BOLD fMRI and images of an animal stimulated on the left forepaw. These images demonstrate that the activation is correctly located by speckle contrast. Furthermore, following the transformation of the recovered into the MRI coordinates, Fig. 7(c) demonstrates that the maximum change of occurs on the cortex region and not on the overlying skull. Similar images were obtained for the right forepaw stimulation [Figs. 7(d)–7(f)]. 3.4.Summary of Results over All AnimalsFigure 8(a) shows the time courses of the changes in due to individual left forepaw stimulations for a representative animal at a depth , which corresponds to the cortex layer. An initial overshoot at the beginning of the stimulation period is visible for all trials. Despite that the individual responses show considerable changes during the recovery period, the averaged response (black line) indicates that returns to baseline. Figure 8(b) illustrates the due to left forepaw stimulation for each animal, where a consistent increase in during the activation period is visible across all animals. Figure 8(c) shows averaged over all five animals. A sharp increase in blood flow can be observed during the stimulation period. However, as mentioned previously (Sec. 3.2), the increase of starts before the stimulation. The period of influence of this artifact on the reconstruction is indicated with the shaded region outside the stimulation stage (black box). The corresponding sham responses for each animal are shown in Fig. 8(d), where no activation but flat responses can be seen during the stimulation period. Table 1 summarizes the estimated activation area for each individual at the slice with the maximum change. Table 1Results from individual rats for both left and right stimuli.
4.DiscussionIn this work, we have demonstrated three-dimensional monitoring of the cerebral blood flow response due to functional stimuli using high-density SCOT through the intact skull of the rat’s head. The results show that the location and the spatial extent of the activation maps are in agreement with BOLD fMRI studies under a similar stimulation paradigm.42 Figure 6(a) shows a clear distinction between the different stages of the experiment and more importantly, the maximum change is correctly located at the cortex layer ().42 The time trace of [Fig. 6(b)] shows a relatively rapid and sustained increase during the stimulation period. However, care must be taken to interpret the apparent increase before the start of the stimulation, which is introduced by the moving window reconstruction scheme. In the future, the temporal resolution can be improved by calculating the speckle contrast over space instead of time in sequential frames using a denser detection array structure while maintaining the high frame rate. If our method is further utilized, its effects can be minimized by considering an average of the forward and backward moving window, by explicitly accounting for the moving window using a weighing function in the postprocessing and by other methods that are utilized in similar windowing schemes. This could be the topic of further investigation in the future. In this study, we have opted for the current detector array for simplicity. In fact, speckle data can be acquired at even higher frame rates in animals43 and in adult humans44 that may in the future allow the consideration of the estimation of other biomarkers in addition to CBF. For example, with the improved temporal resolution, it would be possible to map the pulsatility of the cerebral blood flow due to cardiac cycle as a marker for vascular stiffness43 and intracranial pressure.45 The spatial extent of the activation listed in Table 1 is in agreement with similar studies,11 and also with the size of the activation reported by other diffuse optical modalities, for example, the spatial extent obtained with SCOT is , which is very close to the activation area obtained with DOT which is .16 However, to show the volumetric change instead of the activation area, one would require a statistical analysis that would take into account factors such as differential effects or regularization at different slides and the hemodynamic response function.46 Figure 7 provides further confirmation of the accuracy of the SCOT technique in the location and the spatial extent of the activation. In particular, Figs. 7(c) and 7(f) display the maximum at the cortex and a decrease as the depth increases. However, the smooth and continuous decrease of at deeper layers () is partly a consequence of the regularization method. The purpose of regularization is to stabilize the inversion process by finding a trade-off between the accuracy of the solution and the influence of noise, where this is achieved by attenuating the effect of higher-order modes, which result in smoother solutions. Additionally, it is well-known that recovered perturbations in the reflectance geometry tend to be located closer to the surface.40 Sharper changes can be obtained by adapting fully nonlinear iterative schemes which are readily available in open access software such as NIRFAST or TOAST for SCOT47,48 which would be the topic for further research. SCOT provides a unique combination of deep tissue sensitivity together with a relatively high spatial resolution for the tomography of CBF changes. The possibility of high-density measurements contributed to an improvement in spatial resolution of 1 mm. Similar developments in DOT49 provided substantial improvements in the spatial resolution and in the minimization of localization errors. High-density measurements allow the sampling of the brain tissue with a large number of overlapping measurements50 as a result, each point in the imaging space is better constrained and also less sensitive to noise during the inversion process. On the contrary, high-density data do not scale well in DCS/DCT because the monetary cost is prohibitively large since it requires expensive fast detectors for every added detector position.18,19,23 Figure 8 shows the performance of SCOT for the imaging of CBF in detail. As it is very typical of neuroimaging methods, intertrial, intra-animal, and inter-animal averaging were utilized. This was originally demonstrated for the measurement of CBF due to forepaw stimulation in Ref. 51, where they have characterized different sources of variability. In particular, Fig. 8(a) displays the individual responses for the left forepaw stimulation. The first point to note is that SCOT can characterize changes due to individual trials with an agreeable contrast and SNR. The variability is partly due to the variability introduced by the measurement method but also due to physiological variations in response to each trial including potential habituation effects. It is important to emphasize that the sharp increase in at the beginning of the stimulation period occurs in all trials and contributes to obtaining a robust peak in the averaged response (black line). Figure 8(b) shows the after averaging over these trials for each animal again due to left forepaw stimulation. As expected, there are intra-animal variations presumably due to differences in anatomy, the dynamics of its physiology and condition at a given moment. However, the consistent initial overshoot followed by the persistent activation during the stimulation period, observed across all animals, demonstrates that SCOT is capable of imaging CBF in a robust manner. This characteristic is further supported by Fig. 8(c), where the grand average is plotted against the individual responses for the five animals and from the stimulation of both hemispheres. Baseline, activation, and recovery stages are markedly distinguishable from each other. For comparison, Fig. 8(d) shows the sham responses of the same animals, where mainly flat responses characterized the trends and allow one to appreciate the repeatability of the method. We note that a Wilcoxon test has demonstrated that this response reaches statistical significance in all animals during stimuli but not during sham. However, a full-fledged statistical analysis using a general linear model is beyond the scope of this work. Taken together, Figs. 8(a)–8(d) demonstrate the feasibility of tomographic imaging of changes in from a single trial level to a population level, with a considerable improvement of the response due to the effect of averaging. This is not always true for all neuroimaging methods. Future works using multimodal approaches, e.g., combining DOT with SCOT and/or different fMRI methods with SCOT can be envisioned. These methods would enable a quantitative comparison of the CBF response to that of the oxygenation and derive the changes in cerebral metabolic rate of oxygen extraction. We have not carried this out in this manuscript since the fMRI data were not taken simultaneously and the protocol was not optimized for this purpose. As partially demonstrated in this work, SCOT allows for a range of advantages over traditional DCT. SCOT can be implemented with arrays of detectors using existing technologies, which, as mentioned in Sec. 1 and Refs. 2223.–24, 2728.–29, allows for the improvement of the SNR, FOV, implementation of high-density source–detector pairs, and for potentially low cost, wearable devices.25 The simplicity of the data-type allows for embedding the calculations in firmware,25 which, in turn, allows for robust devices that could be utilized in the field without relying on fragile software and computers. The usability of cameras24,27,29 and camera-like arrays30,35 readily enable noncontact scanning which can bring substantial benefits to imaging. For example, it allows the collection of highly dense data at multiple locations with lesser mechanical limitations such as those due to the location and the physical diameter of the fiber cladding.30 However, noncontact measurements have limitations and we note here, that contact measurements can be implemented with SCOT,30,52 which would allow for measurements through the hair when translating to studies on humans.30 Other implementations can also be envisioned combining spatial, spectral, and temporal information efficiently. Our previous study demonstrated the possibility of tomographic brain imaging of stroke in a mouse model,27 where the present work is an extension to a larger geometry, to deeper and more rapidly evolving signals and to a more challenging experimental paradigm. Combining both contributions, this technology provides new opportunities for the study of the rodent brain after an injury. For example, it would be possible to monitor not only pathological changes in the brain due to a stroke, but also to study the evolution of the functional brain activity after the injury51,53,54 and in the long term, it would also be possible to study longitudinal effects17,30,34 such as those due to rehabilitation. The unique innovation of HD-SCOT is that these studies can be carried out with the same imaging platform in a noninvasive manner. The unique innovation of HD-SCOT is that these analyses can be carried out with the same imaging platform. 5.ConclusionThe feasibility of functional brain monitoring using high-density SCOT has been demonstrated. Robust changes of due to electrical stimulation of forepaw have been observed and the spatial extent, location, and magnitude of changes are in agreement with results reported in fMRI studies and other optical imaging modalities. DisclosuresE. E. Vidal Rosas, T. Dragojević, J. L. Hollmann, and C. Justicia declare no conflict of interest, financial or otherwise. T. Durduran and J. P. Culver are inventors on relevant patents. AcknowledgmentsThis project was funded by Fundació CELLEX Barcelona, Ministerio de Economía y Competitividad/FEDER (PHOTODEMENTIA, DPI2015-64358-C2-1-R), Instituto de Salud Carlos III/FEDER (MEDPHOTAGE, DTS16/00087), the “Severo Ochoa” Program for Centers of Excellence in R\&D (SEV-2015-0522), the Obra Social “la Caixa” Foundation (LlumMedBcn), AGAUR-Generalitat (2017 SGR 1380), LASERLAB-EUROPE IV, and “Fundació La Marató TV3.” We acknowledge useful discussions with Dr. Hari Varma and Dr. Claudia Valdes. ReferencesA. Devor et al.,
“Frontiers in optical imaging of cerebral blood flow and metabolism,”
J. Cereb. Blood Flow Metab., 32
(7), 1259
–1276
(2012). https://doi.org/10.1038/jcbfm.2011.195 Google Scholar
A. Villringer and U. Dirnagl,
“Coupling of brain activity and cerebral blood flow: basis of functional neuroimaging,”
Cerebrovasc. Brain Metab. Rev., 7
(3), 240
–276
(1995). Google Scholar
A. Grinvald et al.,
“Functional architecture of cortex revealed by optical imaging of intrinsic signals,”
Nature, 324
(6095), 361
–364
(1986). https://doi.org/10.1038/324361a0 Google Scholar
A. Gibson and H. Dehghani,
“Diffuse optical imaging,”
Philos. Trans. A. Math. Phys. Eng. Sci., 367
(1900), 3055
–3072
(2009). https://doi.org/10.1098/rsta.2009.0080 Google Scholar
S. Fantini, B. Frederick and A. Sassaroli,
“Perspective: prospects of non-invasive sensing of the human brain with diffuse optical imaging,”
APL Photonics, 3
(11), 110901
(2018). https://doi.org/10.1063/1.5038571 Google Scholar
H. Obrig,
“NIRS in clinical neurology—a ‘promising’ tool?,”
Neuroimage, 85 535
–546
(2014). https://doi.org/10.1016/j.neuroimage.2013.03.045 NEIMEF 1053-8119 Google Scholar
Y. Hoshi,
“Functional near-infrared optical imaging: utility and limitations in human brain mapping,”
Psychophysiology, 40
(4), 511
–520
(2003). https://doi.org/10.1111/psyp.2003.40.issue-4 Google Scholar
M. Ferrari, L. Mottola and V. Quaresima,
“Principles, techniques, and limitations of near infrared spectroscopy,”
Can. J. Appl. Physiol., 29
(4), 463
–487
(2004). https://doi.org/10.1139/h04-031 Google Scholar
A. K. Dunn et al.,
“Dynamic imaging of cerebral blood flow using laser speckle,”
J. Cereb. Blood Flow Metab., 21
(3), 195
–201
(2001). https://doi.org/10.1097/00004647-200103000-00002 Google Scholar
T. Durduran et al.,
“Diffuse optics for tissue monitoring and tomography,”
Rep. Prog. Phys., 73
(7), 076701
(2010). https://doi.org/10.1088/0034-4885/73/7/076701 Google Scholar
T. Durduran et al.,
“Spatiotemporal quantification of cerebral blood flow during functional activation in rat somatosensory cortex using laser-speckle flowmetry,”
J. Cereb. Blood Flow Metab., 24 518
–525
(2004). https://doi.org/10.1097/00004647-200405000-00005 Google Scholar
R. Bonner and R. Nossal,
“Model for laser Doppler measurements of blood flow in tissue,”
Appl. Opt., 20
(12), 2097
–2107
(1981). https://doi.org/10.1364/AO.20.002097 APOPAI 0003-6935 Google Scholar
U. Lindauer, A. Villringer and U. Dirnagl,
“Characterization of CBF response to somatosensory stimulation: model and influence of anesthetics,”
Am. J. Physiol., 264
(4), H1223
–H1228
(1993). https://doi.org/10.1152/ajpheart.1993.264.4.H1223 Google Scholar
D. A. Boas and Y. Campbell,
“Scattering and imaging with diffusing temporal field correlations,”
Phys. Rev. Lett., 75 1855
–1858
(1995). https://doi.org/10.1103/PhysRevLett.75.1855 Google Scholar
J. P. Culver et al.,
“Volumetric diffuse optical tomography of brain activity,”
Opt. Lett., 28
(21), 2061
–2063
(2003). https://doi.org/10.1364/OL.28.002061 Google Scholar
J. P. Culver et al.,
“Evidence that cerebral blood volume can provide brain activation maps with better spatial resolution than deoxygenated hemoglobin,”
Neuroimage, 27 947
–959
(2005). https://doi.org/10.1016/j.neuroimage.2005.05.052 Google Scholar
M. D. Wheelock, J. P. Culver and A. T. Eggebrecht,
“High-density diffuse optical tomography for imaging human brain function,”
Rev. Sci. Instrum., 90
(5), 051101
(2019). https://doi.org/10.1063/1.5086809 Google Scholar
S. Han et al.,
“Temporal blood flow changes measured by diffuse correlation tomography predict murine femoral graft healing,”
PLoS One, 13
(5), e0197031
(2018). https://doi.org/10.1371/journal.pone.0197031 Google Scholar
C. Zhou et al.,
“Diffuse optical correlation tomography of cerebral blood flow during cortical spreading depression in rat brain,”
Opt. Express, 14
(3), 1125
–1144
(2006). https://doi.org/10.1364/OE.14.001125 Google Scholar
L. He et al.,
“Noncontact diffuse correlation tomography of human breast tumor,”
J. Biomed. Opt., 20
(8), 086003
(2015). https://doi.org/10.1117/1.JBO.20.8.086003 Google Scholar
C. P. Valdes et al.,
“Speckle contrast optical spectroscopy, a non-invasive, diffuse optical method for measuring microvascular blood flow in tissue,”
Biomed. Opt. Express, 5
(8), 2769
–2784
(2014). https://doi.org/10.1364/BOE.5.002769 Google Scholar
R. Bi et al.,
“Optical methods for blood perfusion measurement—theoretical comparison among four different modalities,”
J. Opt. Soc. Am. A, 32
(5), 860
–866
(2015). https://doi.org/10.1364/JOSAA.32.000860 Google Scholar
Y. Lin et al.,
“Three-dimensional flow contrast imaging of deep tissue using noncontact diffuse correlation tomography,”
Appl. Phys. Lett., 104
(12), 121103
(2014). https://doi.org/10.1063/1.4869469 Google Scholar
R. Bi, J. Dong and K. Lee,
“Deep tissue flowmetry based on diffuse speckle contrast analysis,”
Opt. Lett., 38
(9), 1401
–1403
(2013). https://doi.org/10.1364/OL.38.001401 Google Scholar
T. Dragojević et al.,
“Compact, multi-exposure speckle contrast optical spectroscopy (SCOS) device for measuring deep tissue blood flow,”
Biomed. Opt. Express, 9
(1), 322
–334
(2018). https://doi.org/10.1364/BOE.9.000322 Google Scholar
T. Dragojević et al.,
“High-speed multi-exposure laser speckle contrast imaging with a single-photon counting camera,”
Biomed. Opt. Express, 6
(8), 2865
–2876
(2015). https://doi.org/10.1364/BOE.6.002865 Google Scholar
T. Dragojević et al.,
“High-density speckle contrast optical tomography (SCOT) for three-dimensional tomographic imaging of the small animal brain,”
NeuroImage, 153 283
–292
(2017). https://doi.org/10.1016/j.neuroimage.2017.04.003 Google Scholar
H. M. Varma et al.,
“Speckle contrast optical tomography: a new method for deep tissue three-dimensional tomography of blood flow,”
Biomed. Opt. Express, 5
(4), 1275
–1289
(2014). https://doi.org/10.1364/BOE.5.001275 Google Scholar
C. Huang et al.,
“Noncontact 3-D speckle contrast diffuse correlation tomography of tissue blood flow distribution,”
IEEE Trans. Med. Imaging, 36
(10), 2068
–2076
(2017). https://doi.org/10.1109/TMI.2017.2708661 Google Scholar
A. T. Eggebrecht et al.,
“Mapping distributed brain function and networks with diffuse optical tomography,”
Nat. Photonics, 8
(6), 448
–454
(2014). https://doi.org/10.1038/nphoton.2014.107 Google Scholar
A. T. Eggebrecht et al.,
“A quantative spatial comparison of high-density diffuse optical tomography and fMRI cortical mapping,”
Neuroimage, 61
(4), 1120
–1128
(2012). https://doi.org/10.1016/j.neuroimage.2012.01.124 Google Scholar
Z. J. Lin et al.,
“Volumetric diffuse optical tomography for small animals using a CCD-camera-based imaging system,”
Int. J. Opt., 2012 1
–10
(2012). https://doi.org/10.1155/2012/276367 Google Scholar
U. Dirnagl, C. Iadecola and M. A. Moskowitz,
“Pathobiology of ischaemic stroke: an integrated view,”
Trends Neurosci., 22
(9), 391
–397
(1999). https://doi.org/10.1016/S0166-2236(99)01401-0 Google Scholar
I. Blanco et al.,
“Longitudinal, transcranial measurement of functional activation in the rat brain by diffuse correlation spectroscopy,”
Neurophotonics, 4
(4), 045006
(2017). https://doi.org/10.1117/1.NPh.4.4.045006 Google Scholar
C. Huang et al.,
“Noninvasive noncontact speckle contrast diffuse correlation tomography of cerebral blood flow in rats,”
Neuroimage, 198 160
–169
(2019). https://doi.org/10.1016/j.neuroimage.2019.05.047 Google Scholar
D. A. Boas and A. K. Dunn,
“Laser speckle contrast imaging in biomedical optics,”
J. Biomed. Opt., 15
(February), 011109
(2010). https://doi.org/10.1117/1.3285504 Google Scholar
R. Bandyopadhyay et al.,
“Speckle-visibility spectroscopy: a tool to study time-varying dynamics,”
Rev. Sci. Instrum., 76
(9), 093110
(2005). https://doi.org/10.1063/1.2037987 Google Scholar
A. B. Parthasarathy et al.,
“Robust flow measurement with multi-exposure speckle imaging,”
Opt. Express, 16
(3), 1975
–1989
(2008). https://doi.org/10.1364/OE.16.001975 Google Scholar
P. D. Kaplan et al.,
“Geometric constraints for the design of diffusing-wave spectroscopy experiments,”
Appl. Opt., 32
(21), 3828
–3836
(1993). https://doi.org/10.1364/AO.32.003828 APOPAI 0003-6935 Google Scholar
B. R. White,
“Developing high-density diffuse optical tomography for neuroimaging,”
173
(2012). Google Scholar
M. Watanabe et al.,
“Temporal jitter of the BOLD signal reveals a reliable initial dip and improved spatial resolution,”
Curr. Biol., 23
(21), 2146
–2150
(2013). https://doi.org/10.1016/j.cub.2013.08.057 Google Scholar
J. B. Mandeville and J. J. A. Marota,
“Vascular filters of functional MRI: spatial localization using BOLD and CBV contrast,”
Magn. Reson. Med., 42
(3), 591
–598
(1999). https://doi.org/10.1002/(ISSN)1522-2594 MRMEEN 0740-3194 Google Scholar
D. D. Postnov et al.,
“Cardiac pulsatility mapping and vessel type identification using laser speckle contrast imaging,”
Biomed. Opt. Express, 9
(12), 6388
–6397
(2018). https://doi.org/10.1364/BOE.9.006388 Google Scholar
T. Dragojevíc et al.,
“High-density functional speckle contrast optical tomography (HD-fSCOT) of the adult brain,”
in ECBO,
(2019). Google Scholar
D. Wang et al.,
“Fast blood flow monitoring in deep tissues with real-time software correlators,”
Biomed. Opt. Express, 7
(3), 776
(2016). https://doi.org/10.1364/BOE.7.000776 Google Scholar
F. Scholkmann et al.,
“A review on continuous wave functional near-infrared spectroscopy and imaging instrumentation and methodology,”
Neuroimage, 85
(Pt 1), 6
–27
(2014). https://doi.org/10.1016/j.neuroimage.2013.05.004 Google Scholar
H. Dehghani et al.,
“Near infrared optical tomography using NIRFAST: algorithm for numerical model and image reconstruction,”
Commun. Num. Methods Eng., 25
(6), 711
–732
(2008). https://doi.org/10.1002/cnm.v25:6 Google Scholar
M. Schweiger and S. Arridge,
“The Toast++ software suite for forward and inverse modeling in optical tomography,”
J. Biomed. Opt., 19
(4), 040801
(2014). https://doi.org/10.1117/1.JBO.19.4.040801 Google Scholar
B. R. White and J. P. Culver,
“Quantitative evaluation of high-density diffuse optical tomography: in vivo resolution and mapping performance,”
J. Biomed. Opt., 15
(April), 026006
(2010). https://doi.org/10.1117/1.3368999 Google Scholar
Y. Zhan et al.,
“Image quality analysis of high-density diffuse optical tomography incorporating a subject-specific head model,”
Front. Neuroenerg., 4 6
(2012). https://doi.org/10.3389/fnene.2012.00006 Google Scholar
J. A. Detre et al.,
“Signal averaged laser Doppler measurements of activation-flow coupling in the rat forepaw somatosensory cortex,”
Brain Res., 796
(1–2), 91
–98
(1998). https://doi.org/10.1016/S0006-8993(98)00322-9 BRREAP 1385-299X Google Scholar
K. M. Bergonzi et al.,
“Lightweight sCMOS-based high-density diffuse optical tomography,”
Neurophotonics, 5
(3), 035006
(2018). https://doi.org/10.1117/1.NPh.5.3.035006 Google Scholar
W. B. Baker et al.,
“Noninvasive optical monitoring of critical closing pressure and arteriole compliance in human subjects,”
J. Cereb. Blood Flow Metab., 37
(8), 2691
–2705
(2017). https://doi.org/10.1177/0271678X17709166 Google Scholar
J. Luckl et al.,
“Characterization of periinfarct flow transients with laser speckle and Doppler after middle cerebral artery occlusion in the rat,”
J. Neurosci. Res., 87 1219
–1229
(2009). https://doi.org/10.1002/jnr.v87:5 Google Scholar
BiographyTanja Dragojević received her PhD from ICFO—The Institue of Photonic Sciences, Spain, in the Medical Optics Group. Her research was focused on developing novel speckle based intrumentation and protocols, for preclinical and clinical studies. Currently she is working as a research engineer in the Medical Optics Group on development of speckle based intrumentation for clinical and industrial applications. Ernesto E. Vidal Rosas is a research associate in the Department of Medical Physics and Biomedical Engineering at UCL. He obtained a PhD in control engineering at the University of Sheffield, followed by a postdoctoral position at ICFO—The Institue of Photonic Sciences, Spain. Currently, his work is focused on the development of reconstruction algorithms for high-density diffuse optical tomography (HD-DOT). His research interests also include speckle imaging, diffuse correlation spectroscopy/tomography, broad-band spectroscopy and system identification. Joseph L. Hollmann obtained his PhD from Northeastern University, in 2014, worked as a postdoctoral fellow at ICFO—The Institute of Photonic Sciences—and moved onto industry afterwards. His research interests cover a large variety of topics ranging from laser speckles in turbid media to others. Joseph P. Culver is a professor of radiology at Washinton University. He obtained a PhD in physics at the University of Pennsylvania for work in ultrafast infrared laser spectroscopy. As a postdoc, he developed diffuse optical tomography systems for imaging breast cancer and imaging cerebal hemodynamics in animals. His lab explores ways of leveraging optical measurements for neuroimaging, with a focus on development of diffuse optical tomography techniques for mapping human brain function. Carles Justicia received his PhD in biology from the University of Barcelona in 2001, working on death and survival pathways activated after stroke. He specialized in MR imaging at the Max Planck Institute for Neurological Research in Cologne. He is currently a senior researcher at the Biomedical Research Institute in Barcelona (IIBB-CSIC) and is part of the group “Brain ischemia: Clinical and experimental studies” at IDIBAPS, where he investigates vascular changes associated with stroke and aging. Turgut Durduran is an ICREA professor at ICFO—The Institute of Photonic Sciences (Spain)—where he leads the Medical Optics Group. His research interests revolve around the use of diffuse light to noninvasively probe tissue function. The group develops new technologies and algorithms and routinely translates them to preclinical, clinical, and industrial applications. |