High-resolution maps of polarization anisotropies of the cosmic microwave background (CMB) are in high demand, since the discovery of primordial B-modes in the polarization patterns would confirm the inflationary phase of the universe that would have taken place before the last scattering of the CMB at the recombination epoch. Transition edge sensors (TES) and microwave kinetic inductance detectors (MKID) are the predominant detector technologies of cryogenic detector array-based CMB instruments that search for primordial B-modes. We propose another type of cryogenic detector to be used for CMB survey: a magnetic microbolometer (MMB) that is based on a paramagnetic temperature sensor. It is an adaption of state-of-the-art metallic magnetic calorimeters (MMCs) that are meanwhile a key technology for high resolution α, β, γ, and x-ray spectroscopy as well as the study of neutrino mass. The effort to adapt MMCs for CMB surveys is triggered by their lack of Johnson noise associated with the detector readout, the possibility of straightforward calibration and higher dynamic range given it possesses a broad and smooth responsivity dependence with temperature, and the absence of Joule dissipation which simplifies the thermal design. A brief proof of concept case study is analyzed, taking into account typical constraints in CMB measurements and reliable microfabrication processes, to assess the suitability of metallic magnetic sensors in CMB experiments. The results show that MMBs provide a promising technology for CMB polarization survey as their sensitivity can be tuned for background limited detection of the sky while simultaneously maintaining a low time response to avoid distortion of the point-source response of the telescope. As the sensor technology and its fabrication techniques are compatible with TES-based bolometric detector arrays, a change of detector technology would even come with very low cost.
QUBIC (Q and U bolometric interferometer for cosmology) is an international ground-based experiment dedicated to the measurement of the polarized fluctuations of the cosmic microwave background (CMB). It is based on bolometric interferometry, an original detection technique which combines the immunity to systematic effects of an interferometer with the sensitivity of low temperature incoherent detectors. QUBIC will be deployed in Argentina, at the Alto Chorrillos mountain site near San Antonio de los Cobres, in the Salta province. The QUBIC detection chain consists of 2048 NbSi transition edge sensors (TESs) cooled to 320 mK. The voltage-biased TESs are read out with time domain multiplexing based on superconducting quantum interference devices (SQUIDs) at 1 K and a novel SiGe application-specific integrated circuit (ASIC) at 60 K allowing an unprecedented multiplexing (MUX) factor equal to 128 to be reached. The current QUBIC version is based on a reduced number of detectors (1/4) in order to validate the detection technique. The QUBIC experiment is currently being validated in the lab in Salta (Argentina) before going to the site for observations. This paper presents the main results of the characterization phase with a focus on the detectors and readout system.
The Q and U Bolometric Interferometer for Cosmology (QUBIC) Technical Demonstrator (TD) aiming to shows the feasibility of the combination of interferometry and bolometric detection. The electronic readout system is based on an array of 128 NbSi Transition Edge Sensors cooled at 350mK readout with 128 SQUIDs at 1K controlled and amplified by an Application Specific Integrated Circuit at 40K. This readout design allows a 128:1 Time Domain Multiplexing. We report the design and the performance of the detection chain in this paper. The technological demonstrator unwent a campaign of test in the lab. Evaluation of the QUBIC bolometers and readout electronics includes the measurement of I-V curves, time constant and the Noise Equivalent Power. Currently the mean Noise Equivalent Power is ~ 2 x 10-16W= p √Hz
QUBIC (a Q and U Bolometric Interferometer for Cosmology) is a next generation cosmology experiment designed to detect the B-mode polarisation of the Cosmic Microwave Background (CMB). A B-mode detection is hard evidence of Inflation in the ΛCDM model. QUBIC aims to accomplish this by combining novel technologies to achieve the sensitivity required to detect the faint B-mode signal. QUBIC uses technologies such as a rotating half-wave plate, cryogenics, interferometric horns with self-calibration switches and transition edge sensor bolometers. A Technical Demonstrator (TD) is currently being calibrated in APC in Paris before observations in Argentina in 2021. As part of the calibration campaign, the spectral response of the TD is measured to test and validate QUBIC's spectro-imaging capability. This poster gives an overview of the methods used to measure the spectral response and a comparison of the instrument data with theoretical predictions and optical simulations.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
INSTITUTIONAL Select your institution to access the SPIE Digital Library.
PERSONAL Sign in with your SPIE account to access your personal subscriptions or to use specific features such as save to my library, sign up for alerts, save searches, etc.