Paper
8 February 2018 Wavelength comparison for laser induced breakdown spectroscopy caries detection
Author Affiliations +
Proceedings Volume 10473, Lasers in Dentistry XXIV; 104730K (2018) https://doi.org/10.1117/12.2288373
Event: SPIE BiOS, 2018, San Francisco, California, United States
Abstract
Laser Induced Breakdown Spectroscopy (LIBS) is a technique capable to perform elemental analyses of a variety of samples, independent of matter state. Other spectroscopy techniques may require a destructive and time-consuming sample preparation. On the other hand, LIBS is a less destructive technique with no (or considerably less) sample preparation, using a relatively simple experimental setup. LIBS also provides a multielement analysis into one single spectrum acquisition, applying a Nd:YAG short-pulsed laser to ensure the stoichiometry between the sample and the generated plasma. LIBS have been applied on the study of carious lesions using a Nd:YAG into its fundamental emission at 1064 nm. It was shown that ratio of P/Ca and Zn/Ca can be used to monitor the cariogenic process. Another minor elements, e.g. C and Cu, associated with bacteria biofilm were also measured with the Nd:YAG laser. The fundamental wavelength emission (1064 nm) of Nd:YAG is coincident with a hydroxyapatite transmission window and it may affect the result. In order to address this issue a study used the second harmonic of the Nd:YAG laser at 532 nm. It was show that it is also possible perform LIBS on carious lesion using the Nd:YAG at 532 nm. However, there is not a work direct comparing the LIBS at 532 nm and 1064 nm for carious lesion detection. So, the aim of this work was to investigate the influence of laser wavelength on the LIBS performance for carious lesion detection. In both cases the carious lesion was detected with the advantage of no interference with hydroxyapatite at 532 nm.
© (2018) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Marcello M. Amaral, Marcus P. Raele, Patrícia A. Ana, Sílvia C. Núñez, Claudia B. Zamataro, and Denise M. Zezell "Wavelength comparison for laser induced breakdown spectroscopy caries detection", Proc. SPIE 10473, Lasers in Dentistry XXIV, 104730K (8 February 2018); https://doi.org/10.1117/12.2288373
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Laser induced breakdown spectroscopy

Nd:YAG lasers

Teeth

Dental caries

Plasma

Spectroscopy

Back to Top