|
I.IntroductionLISA will consist of three spacecraft forming an equilateral triangle with five million kilometer side length trailing the Earth in its heliocentric orbit. The triangular plane rotates over a year, while its normal remains tilted at 30° to the plane of the ecliptic and pointed towards the sun. In LISA laser heterodyne interferometry will be used to measure the relative displacement of test masses shielded inside the spacecraft. Each spacecraft houses two optical benches, each including a test mass, as illustrated in Fig. 1. On the optical bench heterodyne interferometry will take place. The interferometric metrology system to measure the test mass displacement should achieve a noise level of . The interferometric metrology system of each arm is split into three parts as shown in Fig. 2. At the end of each interferometric link there is an optical bench, which measures the distance to the other optical bench (science interferometer) and its test mass (test mass interferometer). Within the framework of the ESA LISA technology development, a LISA Optical Bench (LISA OB) is under construction [2][3]. For verification of the LISA OB, the beam of the far spacecraft is provided by a telescope simulator. Part of the simulator bench will be also a test mass simulator which consists of an actuator mounted gold mirror. II.LISA optical benchThe design of the LISA OB is presented in Fig. 3a. The optical bench forms several interferometers and also has an acquisition sensir anda backfiber link. Figure 3 illustrates all the interferometers: the test mass interferometer (Fig. 3b), reference interferometer (Fig. 3c), science interferometer (Fig. 3d), the backlinkfiber to the other optical bench (Fig. 3e) and the light to the telescope (Fig. 3f). III.Telescope simulatorThe outgoing beam from the LISA OB to the other spacecraft is steered by the so-called PAAM actuator [7]. The initial misalignment of the telescope simulator and the outgoing beam pointing have to be corrected on the telescope simulator bench. Two mirrors (M101 and M102) are mounted on piezo driven actuators on the telescope simulator to correct for the PAAM movement. IfoCAD [4] was used to design the layout shown in Fig. 4. IfoCAD is a raytracing program, which simulates the path of a Gaussian beam passing through programmed components with consideration of their properties. The local fibre injector is located on the top right side. S-polarised light is injected onto the bench. To purify the polarisation the light gets reflected by a polarisation beamsplitter (p-pol light is transmitted and dumped with a beam dump) before the beam splits into two parts. The first part splits again into the commissioning and into a beam which will be guided to the LISA OB. The second part of the beam stays on the telescope simulator bench and is the local beam for the interferometer with the light coming from the LISA OB. Good alignment at BS103 between the local beam and the received beam from the LISA OB is achieved by actuator mounted mirrors M101 and M102 in the local beam path. The lens system, consisting of two lenses on the telescope simulator, transforms the 5 mm collimated outgoing beam of the LISA OB into a 2 mm collimated beam and vice versa. Polarisation optics are used to separate the counter-propagating beams. The outgoing beam of the LISA OB continues through the lens system in p-polarisation before being transmitted through the polarisation beamsplitter PBS102. Its polarisation is changed into s-polarisation via a half waveplate before the superposition with the s-polarised local beam at BS103. The s-polarised local beam reflects at PBS102 and injected into the LISA OB. Independent tests of the stability of the actuator mounted mirror have been carried out. These tests provided information on the stability of a single actuator and its thermal compensating mount. The stability of a single actuator stays below the requirement of . In the case of the test mass simulator these tests are representative since only one actuator is in use. The telescope simulator is operated using a total of four actuators, two in each optical path-therefore a more realistic test scenario of the actuator stability shall be carried out directly related to their later use in the interferometer set-up. For this reason, an additional second fiber injector is providing the so-called commissioning beam for independent commissioning measurement of the telescope simulator without the light from the LISA OB. The commissioning interferometer measures the stability of the telescope simulator bench without having any actuators in its optical path and acts as a reference interferometer. At BS103 the stability of the superimposed beams travelling over the actuators will be measured. A mirror and a quarter-wave plate is located in the optical path between the actuator mirror M3 and BS6 (shown in Fig. 5) to close the optical path. The s-polarised beam is reflected back and transformed into a p-polarised beam by passing twice through the quarter-wave plate and such passes through PBS102, before it gets combined with the local beam at BS103. Also the local beam between BS102 and BS104 has to be blocked for commissioning. The difference of both interferometer measurements provides the stability of the complete telescope simulator including all four actuators. IV.ActuatorA thermal compensating mount has been constructed to minimise thermally driven displacements of the actuator mounted mirrors shown in Fig. 6. Three feet are glued to the baseplate and allow the thermal compensating mount to bend in one direction. The amount of bending will be compensated by the thickness increase of the adapter plate. The rotation point of the actuator (Newport AG-M100N-V6) is 7.4±0.05 mm from its outer edges. The center of the reflection point of the mirror has to be placed within this rotation point such that no coupling from tilt into the longitudinal pathlength is induced. V.ConstructionThe requirements of the construction of the telescope simulator are similar to the LISA OB. The optical bench has to perform measurements within the picometer/√Hz stability range. For this reason the optical bench consists of Zerodur and the optical components are silicate bonded to the bench. Silicate bonding [5] is a technique which joins glass components such that they are forming a quasi-monolithic structure. The alignment of the components is critical as after bonding they cannot be removed without causing damage to the baseplate. For less position-critical components a template is used which defines the position of the components, shown in Fig. 7. In total the use of three templates is foreseen; a large main template for most components and two smaller ones. The reference points of the templates are the out-of-plane optics (TMSim and Mup in Fig. 4). The position of the out-of-plane optics is critical since they are steering the beam coming from the LISA OB through holes in the Zerodur baseplate and vice versa. Therefore the out-of-plane optics will be positioned for silicate bonding using a CMM (Coordinate Measurement Machine). The alignment of the reference interferometer on the telescope simulator can not be done fully using a template. Here the interferometer will be constructed by optimising the heterodyne signal in real-time during silicate bonding. The actuator mounted mirrors, beam dumps, and photo-diodes will be positioned using the CMM on thermal compensating side slabs beside the Zerodur baseplate. The two photodiodes reading out the science interferometer have to be positioned on linear actuators since the combined beam positioning is variable due to the PAAM and actuator movements on the telescope simulator. VI.CommissioningFor the commissioning of the telescope simulator a mirror and a quarter waveplate will be temporarily placed in the optical beam path. For stability the mirror will be optically contacted to the telescope baseplate and the quarter wave-plate mount glued such that it can be removed afterwards. The commissioning of the telescope simulator will provide stability measurement of the actuators, also such an end-to-end performance measurement can be carried out using the LISA photodiodes [8] and the LISA phasemeter [9]. This will be an important performance measurement of the system. VII.ConclusionThe LISA OB requires a simulator to test the test mass interferometer and the science interferometer. Both of the simulators are placed on the same Zerodur baseplate and will be positioned above the LISA OB. A gold coated mirror mounted on an actuator simulates the test mass. The movement of the beam due to the PAAM on the LISA OB will be compensated using actuators in the telescope simulator. In addition both the layout and construction of the optical bench has been presented. A template will be used for positioning most optical components. Already several aspects of the technology development within the frame of the LISA OB development have been identified for further investigation. The end-to-end performance of the telescope simulator will be one of them. AcknowledgmentWe acknowledge funding by the European Space Agency within the project “Optical Bench Development for LISA” and support by the Deutsches Zentrum für Luft und Raumfahrt (DLR) with funding from the Bundesministerium für Wirtschaft und Technologie (DLR project reference 50 OQ 0601), and the Science and Technology Facilities Council (STFC), and the United Kingdom Space Agency (UKSA). We thank the German Research Foundation for funding the cluster of Excellence QUEST - Centre for Quantum Engineering and Space-Time Research. References
“LISA - Unveiling a hidden universe, Assessment Study Report, ESA/SRE(2011)3,”
European Space Agency2011). Google Scholar
L. d’Arcio,
“Optical bench development for LISA,”
in Proc. of the International Conference on Space Optics,
(2010). Google Scholar
M. Tröbs,
“Testing the LISA optical bench,”
in Proc. of the International Conference on Space Optics,
(2012). Google Scholar
Gudrun Wanner,
“Methods for simulating the readout of lengths and angles in laser interferometers with Gaussian beams,”
Optics Communications,
(17479), Google Scholar
Johanna Bogenstahl,
“Interferometery for the space mission LISA Pathfinder,”
(2010). Google Scholar
“NGO - Revealing a hidden Universe: opening a new chapter of discovery, Assessment Study Report, ESA/SRE(2011)19, December 2011, European Space Agency,”
Google Scholar
J. A. C. M. Pijnenburg, N. Rijnveld,
“Picometer stable scan mechanism for gravitational wave detection in space: LISA PAAM,”
in ICSO 2010 International Conference on Space Optics,
Google Scholar
F Guzmán Cervantes,
“Characterization of photoreceivers for LISA,”
Class. Quantum Grav., 28 094010
(2011). Google Scholar
Juan José Esteban Delgado,
“Laser Ranging and data communication for the Laser Interferometer Space Antenna,”
(2012). Google Scholar
|