Open Access Paper
8 July 2021 Single-shot picosecond resolution Fourier transform holographic microscopy with large field of view using a compact soft x-ray laser
Shoujun Wang, Alex Rockwood, Yong Wang, Wei-Lun Chao, Patrick Naulleau, Huanyu Song, Carmen S. Menoni, Mario Marconi, Jorge J. Rocca
Author Affiliations +
Proceedings Volume 11886, International Conference on X-Ray Lasers 2020; 118860O (2021) https://doi.org/10.1117/12.2594832
Event: XVII International Conference on X-Ray Lasers, 2020, Online Only
Abstract
We demonstrate single-shot Fourier transform holography with a 7 μm diameter field of view and picosecond time resolution using a highly coherent ~5 ps pulse duration tabletop Ni-like molybdenum soft X-ray laser at 18.9 nm wavelength. The essentially full spatial coherence soft X-ray source with close to diffraction-limited divergence was implemented utilizing a dual-plasma amplifier scheme. The high flux illumination of ~ 2×1011 photons per pulse was split using a Fresnel zone plate to generate the object and reference beams creating high contrast Fourier transform holograms. The final image was numerically reconstructed by 2D Fourier transform. A minimum half-pitch spatial resolution of 62 nm was obtained.

1.

INTRODUCTION

Disciplines with high societal impact like material science, biology, medicine etc. relies on sophisticated imaging techniques for regular diagnostics and research. In fact, the significant advances in high resolution imaging produced in the last decades had potentiated several aspects of these disciplines and opened new fields like for example those associated with nanotechnology. To reach nanoscale spatial resolutions it is customary to utilize charged particles beams in electron and ion microscopes that are capable to produce astonishing high-resolution images reaching even the molecular scale. However, the utilization of charged particles sometimes makes this method unsuitable for some applications due to the interaction of the charged particles with the sample.

Utilization of photons can overcome this limitation, offering also the possibility of ultrafast time resolution. Optical microscopy is directly associated with the advancement of science in the last centuries, and nowadays it is customary to use microscopes in almost all scientific disciplines. In the optical realm, the achievable spatial resolution is directly proportional to the wavelength of the illumination. Thus, one strategy to improve the resolution is to reduce the wavelength of the illumination and improve the resolution proportionally. A particular spectral range well suited to image nanostructures is the extreme ultraviolet (EUV) and soft x-ray (SXR) region. In this spectral range, there are available several accelerator-based national facilities14, as well as by more compact sources 510 capable to deliver enough photon flux to attempt high resolution images on nanoscale specimens efficiently. In particular, as discussed below, soft x-ray lasers produce a large number of photons in a single pulse of picosecond duration allowing for ultrafast single-shot imaging of dynamic phenomena in the nanoscale.

The availability of these short wavelength sources motivated extensive work developing full field microscopes using zone plate (ZP) lenses. Of particular impact are the microscopes implemented with compact plasmas-based discharge pumped11,12 and laser-pumped1315 EUV/SXR lasers, that achieved resolutions down to 38 nm resolution in transmission mode15 and 55 nm in reflection mode14. Also, stroboscopic imaging of oscillating magnetic probes in the EUV using ZPs was demonstrated with ~ 1ns temporal resolution and 54 nm spatial resolution using a 46.9 nm capillary discharge laser16. Instead of using ZP optics, an alternative approach very well adapter to the EUV is to eliminate optical components all together and measure the far field diffraction pattern of the object. This is the approach of Fourier transform holography (FTH)17 and coherent diffractive imaging (CDI)18. However, the absence of optics that gather the light into the image plane imposes for these approaches the challenge to obtain enough flux to be able to record single-shot images with high spatial and temporal resolution12,16,1924.

The FTH hologram is recorded as the interference between the diffracted wave by the object and a point source reference wave. The image is then numerically reconstructed simply via a 2D Fast Fourier Transformation (FFT) of the hologram, making FTH an ideal method for high-resolution real-time imaging. In FTH there are several factors that determine the spatial resolution and the field of view (FOV). In the reconstruction process, the image is obtained as the convolution of the object and the point source reference beams. As such, the resolution in the reconstructed image depends on the size of the reference beam, this is how close the reference source is to a delta function-like reference.

Requiring small size refence beam, imposes the immediate challenge in the fabrication technique to create a small pinhole aperture. In turn, a small pinhole restricts dramatically the intensity of the reference beam, producing interference fringes with very poor visibility if the object and reference beams have very dissimilar intensities. As a consequence, the low flux requires a long exposure time to increase the hologram signal-to-noise ratio (SNR). Anyway, there are some clever means to partially overcome this inconvenience. An alternative setup to improve the SNR is utilizing multiple reference sources, to extend the detection limit25. Replacing the reference pinhole with a uniformly redundant array also showed improvement in the resolutions to 44 nm26. On the other hand, to image a large object it is necessary to have a large FOV, which generates high spatial frequency fringes. Consequently, the numerical aperture and the detector’s pixel size limit the maximum spatial frequency that can be recorded and therefore sets a limit on the spatial resolution. Extended FOV FTH spanning 180 μm has been demonstrated by applying spatial multiplexing using a filtered soft X-ray beam originating from an undulator source27. Such full-field of view imaging needs long exposure time and/or a large photon flux that is only achievable at synchrotrons and Free-Electron Lasers (FELs)28.

Table-top EUV coherent sources have the unique advantage to enable a more readily access to experiments, as compared with large EUV time-shared facilities. The successful demonstration of an X-ray nanoscale imaging with high spatial and temporal resolution in a large FOV at table-top scale undoubtedly will provide an attractive tool that can have a significant impact. Such compact table-top system could use sources that include high harmonic generation (HHG) and plasma-based SXR lasers.

With HHG CDI has been successfully demonstrated at table-top scale29,30 with a best resolution of 22 nm31, but in a single shot a resolution of 119 nm was reported [20]. FTH using a HHG source also been demonstrated with a resolution of 53 nm32. However, the limited photon flux per-pulse of HHG sources requires long exposure times. For the same reason, the imaged area was limited to less than 9 square micrometers. Recently by increasing HHG repetition rate to 100 kHz, a halfpitch resolution of 34 nm was obtained with a reduced exposure time of tens of seconds. In this case, the imaged object area was only 0.075 μm2.33

Plasma-based SXR lasers provide a much larger number, ~1011, photons per-pulse, which in principle is a clear advantage over HHG sources for high temporal resolution (single-shot) FTH recording. SXR and EUV holograms have a very prolific history. The first hologram obtained with a plasma based SXR laser was a Gabor hologram34 more than 30 years ago. More recently a resolution of 87 nm has been obtained using a FTH setup with a FOV of 9 μm2.35 Using an EUV capillary discharge laser source operating at 46.9 nm wavelength a spatial resolution of 169 nm was obtained in a single laser pulse with temporal resolution of ≈1ns 21,36. Single-shot CDI with 180 nm resolution using an 18.9 nm Ni-like Mo SXR laser was also reported 37.

In this work, we implemented a single-shot picosecond resolution FTH using a setup that a custom-made ZP with a central aperture that plays the role of a beam splitter, similar to the experimental setup used with a synchrotron source17. The ZP generates both the point source for the reference source (third order focus) and the illuminating (central opening) beams. In contrast to FTH in which a pinhole produces a reference beam, this geometry increases by orders of magnitude the flux and therefore the area of the object that can be recorded by equalizing the intensities of the object and reference beams. Moreover, by employing a dual-plasma amplifier laser scheme the spatial coherence and beam divergence of the SXR lasers source are dramatically improved. A large number of coherent photons were concentrated on the ZP area generating high contrast holograms which is essential for single-shot large FOV FTH. A half-pitch resolution of up to 62 nm was achieved with single-shot SXR laser illumination, yielding a temporal resolution of 5 ps. The area imaged was 38.5 μm2 i.e. near an order of magnitude larger than formerly reported experiments with SXR lasers35 and more than 500 times the area in experiments using HHG sources33.

2.

EXPERIMENTAL SETUP

The experiment was conducted at Colorado State University’s ALEPH laser facility. A high quality SXR coherent beam is essential to demonstrate the ideal of large FOV FTH in a single shot. To improve the spatial coherent of the SXR laser source the self-seeded dual-plasma configuration38 was employed. Particularly two spatially separated plasma columns were pumped by two sets of beams coming from same laser with adequate delay intervals. The small cross-section area of the second plasma gain region acts as a spatial filter that filtering only small fraction of the amplified spontaneous emission from the first plasma amplifier. This filtered fraction, about 20 μm in diameter, has good wavefront and spatial coherent is going to be further amplified. We chose Ni-like Mo SXR laser as the source. The generated dual-plasma self-seeded SXR laser beam has a near-diffraction limited beam divergence of 0.66 mrad and nearly full transverse coherent with up to ~ 2×10n photons per pulse at λ=18.9 nm39. The pulse duration of this type of Ni-like collisionally excited grazing incidence plasma-based SXR lasers was measured to be ~5 ps using a streak camera40. This highly coherent bright SXR beam was directed by a flat gold coated mirror at grazing incidence to the FTH experiment.

Figure 1 shows the Fourier holography experiment setup. Ni-like Mo SXR laser illuminates a custom-made condenser ZP with a central aperture that plays the role of a beam splitter generating both the point reference source (third order focus) and the illuminating (central opening) beams. The SXR laser beam passes through the central aperture of the ZP and illuminates the object located in a downstream plane. The ZP focuses the remaining part of the beam into a small pinhole located in the same plane of the object creating the FTH reference beam. Here the pinhole is designed to block other diffraction orders of the ZP, while the spatial resolution defined by the ZP focal spot size. The scattered beam from the object and the reference beam interfere in a CCD camera that records the hologram. The size of the object hole and its distance from the reference hole was selected to assure the interference fringes are resolved at the CCD and there is no superposition between autocorrelation and cross correlation in the FFT reconstruction.

Figure 1.

Schematic setup of Fourier holography experiment. A zone plate is used as a beam splitter. The mask contains a hole to define the reference beam and a semitransparent area to support the sample. The hologram is recorded by a CCD camera. A zoomed-in inset shows the beam that illuminates the sample and the refence beam.

00042_PSISDG11886_118860O_page_3_1.jpg

The use of a ZP can gather a larger number of photos of the illuminating beam and better equalize the intensity between the object and the reference beams, which in turn overcomes the object size limitations in the mask-based FTH. Another advantage is the ZP design can be optimized to generate a tens of nanometer diameter focal spot. In contrast to FTH in which a pinhole produces a reference beam, this geometry increases by orders of magnitude the flux and therefore the area of the object that can be recorded. The ZP used in this experiment is an available ZP designed for 46.9 nm wavelength with self-standing structure that allows for maximum transparency of the SXR laser beam. It contains 623 self-standing zones with an outer diameter of 500 μm, an outer zone width of 200 nm and a center aperture of 30 μm. In this work we use the 3rd order of the ZP which gives a calculated spot size of 81 nm, a NA of 0.14 and a focal length of 1.78mm for λ=18.9 nm. By using a higher diffraction order, it is possible to achieve a smaller focal spot and larger NA, increasing the FTH resolution.

The object was placed at the focal distance of 1.78mm away from the ZP. The sample holder was implemented with a 50 nm thick Si2N3 membrane with coatings to enhance the absorption. A 7 μm diameter object region was left without coating to preserve a region with higher transmission for the beam. The Ag nanowire samples, diameter varied from 180 nm to 120 nm, are randomly spin coated over the region. Additionally, a 3 μm hole was defined in the membrane to allow for the passage of the reference beam produced by the focus of the ZP. The pinhole for the reference beam was located at 8 μm from the center of the sample region. Figure 2 shows two samples images from Scanning electron microscope (SEM) that prepared for the experiment. The CCD camera with the pixel size of 13.5 μm and 2048 × 2048 pixels placed 50 mm away from the sample to capture the diffracted light.

Figure. 2.

SEM images of the two samples used in the experiment. Each sample consists of an opaque membrane with a 7μm hole where silver nanowires were placed. The membrane contains a 3μm diameter hole for the reference beam separated by a center-to-center distance of ~8 μm.

00042_PSISDG11886_118860O_page_4_1.jpg

3.

RESULTS

A typical single-shot hologram and its FFT reconstruction are shown in Figure 3. The raw hologram data was further processed to reduce the influence of the noise. An FFT of the data finally resulted in an image in the object at the plane of the ZP focus. By zooming in on the area of interest the nanowires are clearly visible. Figure 4 compares picosecond resolution single-shot images of two nanowire samples to those obtained from the same samples using a scanning electron microscope.

Figure 3.

(a) Typical single shot SXR laser Fourier holography image with a zoom of the fringe pattern. (b) The Fourier transform of the hologram with zoomed-in inset showing Ag nanowire object.

00042_PSISDG11886_118860O_page_4_2.jpg

Figure 4.

Electron microscope image (a), (c) and corresponding single shot holographic images (b), (d) of the silver nanowires over a 7 μm diameter hole.

00042_PSISDG11886_118860O_page_5_1.jpg

The 10% to 90% knife edge criterium was used to assess the spatial resolution. The reconstruction of the image is the results of the convolution of the object with a point source. Here we assume the source has a Gaussian with FWHM of 81 nm. Convolving a Gaussian function with a step function, produces also a Gaussian profile. This Gaussian profile is the image that we can expect to obtain after the reconstruction from a hard-edge object. The spatial spread for an 81nm FWHM Gaussian to rise from 10% to 90% of its peak value is Δx=58nm. It is consistent with the experimental results we obtained of 62nm which shows in Figure 5 as a typical cross section image, corresponding to the small red segment of Ag nanowires indicated in Figure 4(b).

Figure 5.

Characteristic 10% to 90% knife edge cut of the image showing a spatial resolution of 62 nm.

00042_PSISDG11886_118860O_page_6_1.jpg

The utilization of the ZP to implement the point reference source allowed for an extended field of view of 38.5 μm2. The imaged area could be further increased without sacrificing resolution by enlarging the high transmission area where the sample is located while maintaining its distance to the reference pinhole. This could be achieved using to a half doughnut shape instead of the circle. The area could also be enlarged by increasing the size of the central opening on the ZP, to create a larger illuminated area. Finally, since the reconstruction of the hologram produces an image of the object at the plane where the reference source is located, it would be possible to inspect the object at different planes along the optical axis by displacing the ZP, which will enable one to compose a tomography of the object. With the recent demonstration of sub 8 nm wavelength gain-saturated plasma-based table-top SXR laser10 it will be possible to further improve the resolutions both in time and space using compact table-top systems.

Acknowledgment

The work was supported by the AMOS program of the Office of Basic Energy Sciences, US Department of Energy grant number (DE-FG02-04ER15592). Previous support from DARPA grant D16PC00087 is acknowledged. The experiments were conducted at CSU’s ALEPH laser facility supported by LaserNet US (DE-SC0019076).

REFERENCES

[1] 

Mcneil, B. W. J. and Thompson, N. R., “X-ray free-electron lasers,” Nat. Photonics, 4 (12), 814 –821 (2010). https://doi.org/10.1038/nphoton.2010.239 Google Scholar

[2] 

Faatz, B., Baboi, N., Ayvazyan, V., Balandin, V., Decking, W., Duesterer, S., Eckoldt, H. J., Feldhaus, J., Golubeva, N., Koerfer, M., Laarmann, T., Leuschner, A., Lilje, L., Limberg, T., Noelle, D., Obier, F., Petrov, A., Ploenjes, E., Rehlich, K., “FLASH II: A seeded future at FLASH,” in IPAC 2010 - 1st Int. Part. Accel. Conf, 2152 –2154 (2010). Google Scholar

[3] 

Patterson, B. D., Abela, R., Braun, H.-H., Flechsig, U., Ganter, R., Kim, Y., Kirk, E., Oppelt, A., Pedrozzi, M., Reiche, S., Rivkin, L., Schmidt, T., Schmitt, B., Strocov, V. N., Tsujino, S. and Wrulich, A. F., “Coherent science at the SwissFEL x-ray laser,” New J. Phys., 12 (3), 35012 (2010). https://doi.org/10.1088/1367-2630/12/3/035012 Google Scholar

[4] 

Allaria, E., Badano, L., Bassanese, S., Capotondi, F., Castronovo, D., Cinquegrana, P., Danailov, M. B., D’Auria, G., Demidovich, A., De Monte, R., De Ninno, G., Di Mitri, S., Diviacco, B., Fawley, W. M., Ferianis, M., Ferrari, E., Gaio, G., Gauthier, D., Giannessi, L., “The FERMI free-electron lasers,” J. Synchrotron Radiat., 22 (3), 485 –491 (2015). https://doi.org/10.1107/S1600577515005366 Google Scholar

[5] 

Chatziathanasiou, S., Kahaly, S., Skantzakis, E., Sansone, G., Lopez-Martens, R., Haessler, S., Varju, K., Tsakiris, G. D., Charalambidis, D. and Tzallas, P., “Generation of attosecond light pulses from gas and solid state media,” Photonics, 4 (2), (2017). Google Scholar

[6] 

Rocca, J. J., “Table-top soft x-ray lasers,” Rev. Sci. Instrum., 70 (10), 3799 –3827 (1999). https://doi.org/10.1063/1.1150041 Google Scholar

[7] 

Wang, Y., Granados, E., Pedaci, F., Alessi, D., Luther, B., Berrill, M. and Rocca, J. J., “Phase-coherent, injection-seeded, table-top soft-X-ray lasers at 18.9 nm and 13.9 nm,” Nat. Photonics, 2 (2), 94 –98 (2008). https://doi.org/10.1038/nphoton.2007.280 Google Scholar

[8] 

Alessi, D., Wang, Y., Luther, B. M., Yin, L., Martz, D. H., Woolston, M. R., Liu, Y., Berrill, M. and Rocca, J. J., “Efficient Excitation of Gain-Saturated Sub-9-nm-Wavelength Tabletop Soft-X-Ray Lasers and Lasing Down to 7.36 nm,” Phys. Rev. X, 1 (2), (2011). Google Scholar

[9] 

Depresseux, A., Oliva, E., Gautier, J., Tissandier, F., Nejdl, J., Kozlova, M., Maynard, G., Goddet, J. P., Tafzi, A., Lifschitz, A., Kim, H. T., Jacquemot, S., Malka, V., Ta Phuoc, K., Thaury, C., Rousseau, P., Iaquaniello, G., Lefrou, T., Flacco, A., “Table-top femtosecond soft X-ray laser by collisional ionization gating,” Nat. Photonics, 9 (12), (2015). https://doi.org/10.1038/nphoton.2015.225 Google Scholar

[10] 

Rockwood, A., Wang, Y., Wang, S., Berrill, M., Shlyaptsev, V. N. and Rocca, J. J., “Compact gain-saturated x-ray lasers down to 6.85 nm and amplification down to 5.85 nm,” Optica, 5 (3), 257 –262 (2018). https://doi.org/10.1364/OPTICA.5.000257 Google Scholar

[11] 

Vaschenko, G., Brizuela, F., Brewer, C., Grisham, M., Mancini, H., Menoni, C. S., Marconi, M. C., Rocca, J. J., Chao, W., Liddle, J. A., Anderson, E. H., Attwood, D. T., Vinogradov, A. V., Artioukov, I. A., Pershyn, Y. P. and Kondratenko, V. V., “Nanoimaging with a compact extreme-ultraviolet laser,” Opt. Lett., 30 (16), (2005). https://doi.org/10.1364/OL.30.002095 Google Scholar

[12] 

Brewer, C. A., Brizuela, F., Wachulak, P., Martz, D. H., Chao, W., Anderson, E. H., Attwood, D. T., Vinogradov, A. V., Artyukov, I. A., Ponomareko, A. G., Kondratenko, V. V., Marconi, M. C., Rocca, J. J. and Menoni, C. S., “Single-shot extreme ultraviolet laser imaging of nanostructures with wavelength resolution,” Opt. Lett., 33 (5), (2008). https://doi.org/10.1364/OL.33.000518 Google Scholar

[13] 

Brizuela, F., Wang, Y., Brewer, C. A., Pedaci, F., Chao, W., Anderson, E. H., Liu, Y., Goldberg, K. A., Naulleau, P., Wachulak, P., Marconi, M. C., Attwood, D. T., Rocca, J. J. and Menoni, C. S., “Microscopy of extreme ultraviolet lithography masks with 13.2 nm tabletop laser illumination,” Opt. Lett., 34 (3), (2009). https://doi.org/10.1364/OL.34.000271 Google Scholar

[14] 

Brizuela, F., Carbajo, S., Sakdinawat, A., Alessi, D., Martz, D. H., Wang, Y., Luther, B., Goldberg, K. A., Mochi, I., Attwood, D. T., La Fontaine, B., Rocca, J. J. and Menoni, C. S., “Extreme ultraviolet laser-based table-top aerial image metrology of lithographic masks,” Opt. Express, 18 (14), 14467 –14473 (2010). https://doi.org/10.1364/OE.18.014467 Google Scholar

[15] 

Vaschenko, G., Brewer, C., Brizuela, F., Wang, Y., Larotonda, M. A., Luther, B. M., Marconi, M. C., Rocca, J. J., Menoni, C. S., Anderson, E. H., Chao, W., Harteneck, B. D., Liddle, J. A., Liu, Y. and Attwood, D. T., “Sub-38 nm resolution tabletop microscopy with 13 nm wavelength laser light,” Opt. Lett., 31 (9), 1214 –1216 (2006). https://doi.org/10.1364/OL.31.001214 Google Scholar

[16] 

Carbajo, S., Howlett, I. D., Brizuela, F., Buchanan, K. S., Marconi, M. C., Chao, W., Anderson, E. H., Artioukov, I., Vinogradov, A., Rocca, J. J. and Menoni, C. S., “Sequential single-shot imaging of nanoscale dynamic interactions with a table-top soft x-ray laser,” Opt. Lett., 37 (14), 2994 –2996 (2012). https://doi.org/10.1364/OL.37.002994 Google Scholar

[17] 

McNulty, I., Kirz, J., Jacobsen, C., Anderson, E. H., Howells, M. R. and Kern, D. P., “High-resolution imaging by fourier transform X-ray holography,” Science (80-.), (1992). https://doi.org/10.1126/science.256.5059.1009 Google Scholar

[18] 

Miao, J., Charalambous, P., Kirz, J. and Sayre, D., “Extending the methodology of X-ray crystallography to allow imaging of micrometre-sized non-crystalline specimens,” Nature(1999). https://doi.org/10.1038/22498 Google Scholar

[19] 

Barty, A., Boutet, S., Bogan, M. J., Hau-Riege, S., Marchesini, S., Sokolowski-Tinten, K., Stojanovic, N., Tobey, R., Ehrke, H., Cavalleri, A., Düsterer, S., Frank, M., Bajt, S., Woods, B. W., Seibert, M. M., Hajdu, J., Treusch, R. and Chapman, H. N., “Ultrafast single-shot diffraction imaging of nanoscale dynamics,” Nat. Photonics, 2 (7), (2008). https://doi.org/10.1038/nphoton.2008.128 Google Scholar

[20] 

Ravasio, A., Gauthier, D., Maia, F. R. N. C., Billon, M., Caumes, J. P., Garzella, D., Géléoc, M., Gobert, O., Hergott, J. F., Pena, A. M., Perez, H., Carré, B., Bourhis, E., Gierak, J., Madouri, A., Mailly, D., Schiedt, B., Fajardo, M., Gautier, J., “Single-shot diffractive imaging with a table-top femtosecond soft X-ray laser-harmonics source,” Phys. Rev. Lett., 103 (2), (2009). https://doi.org/10.1103/PhysRevLett.103.028104 Google Scholar

[21] 

Monserud, N. C., Malm, E. B., Wachulak, P. W., Putkaradze, V., Balakrishnan, G., Chao, W., Anderson, E., Carlton, D. and Marconi, M. C., “Recording oscillations of sub-micron size cantilevers by extreme ultraviolet Fourier transform holography,” Opt. Express, (2014). https://doi.org/10.1364/OE.22.004161 Google Scholar

[22] 

Gorkhover, T., Ulmer, A., Ferguson, K., Bucher, M., Maia, F. R. N. C., Bielecki, J., Ekeberg, T., Hantke, M. F., Daurer, B. J., Nettelblad, C., Andreasson, J., Barty, A., Bruza, P., Carron, S., Hasse, D., Krzywinski, J., Larsson, D. S. D., Morgan, A., Mühlig, K., “Femtosecond X-ray Fourier holography imaging of free-flying nanoparticles,” Nat. Photonics, 12 (3), 150 –153 (2018). https://doi.org/10.1038/s41566-018-0110-y Google Scholar

[23] 

Tenboer, J., Basu, S., Zatsepin, N., Pande, K., Milathianaki, D., Frank, M., Hunter, M., Boutet, S., Williams, G. J., Koglin, J. E., Oberthuer, D., Heymann, M., Kupitz, C., Conrad, C., Coe, J., Roy-Chowdhury, S., Weierstall, U., James, D., Wang, D., “Time-resolved serial crystallography captures high-resolution intermediates of photoactive yellow protein,” Science (80-.), 346 (6214), (2014). https://doi.org/10.1126/science.1259357 Google Scholar

[24] 

Lai, Y., Xue, Y., Côté, C. Y., Liu, X., Laramée, A., Jaouen, N., Légaré, F., Tian, L. and Liang, J., “Single-Shot Ultraviolet Compressed Ultrafast Photography,” Laser Photonics Rev., 14 (10), (2020). Google Scholar

[25] 

Schlotter, W. F., Rick, R., Chen, K., Scherz, A., Stöhr, J., Lüning, J., Eisebitt, S., Günther, C., Eberhardt, W., Hellwig, O. and McNulty, I., “Multiple reference Fourier transform holography with soft x rays,” Appl. Phys. Lett., (2006). https://doi.org/10.1063/1.2364259 Google Scholar

[26] 

Marchesini, S., Boutet, S., Sakdinawat, A. E., Bogan, M. J., Bajt, S., Barty, A., Chapman, H. N., Frank, M., HauRiege, S. P., Szöke, A., Cui, C., Shapiro, D. A., Howells, M. R., Spence, J. C. H., Shaevitz, J. W., Lee, J. Y., Hajdu, J. and Seibert, M. M., “Massively parallel X-ray holography,” Nat. Photonics, (2008). https://doi.org/10.1038/nphoton.2008.154 Google Scholar

[27] 

Schlotter, W. F., Lüning, J., Rick, R., Chen, K., Scherz, A., Eisebitt, S., Günther, C. M., Eberhardt, W., Hellwig, O. and Stöhr, J., “Extended field of view soft x-ray Fourier transform holography: toward imaging ultrafast evolution in a single shot,” Opt. Lett., 32 (21), (2007). https://doi.org/10.1364/OL.32.003110 Google Scholar

[28] 

Pfau, B., Günther, C. M., Schaffert, S., Mitzner, R., Siemer, B., Roling, S., Zacharias, H., Kutz, O., Rudolph, I., Treusch, R. and Eisebitt, S., “Femtosecond pulse X-ray imaging with a large field of view,” New J. Phys., (2010). https://doi.org/10.1088/1367-2630/12/9/095006 Google Scholar

[29] 

Sandberg, R. L., Paul, A., Raymondson, D. A., Hädrich, S., Gaudiosi, D. M., Holtsnider, J., Tobey, R. I., Cohen, O., Murnane, M. M., Kapteyn, H. C., Song, C., Miao, J., Liu, Y. and Salmassi, F., “Lensless diffractive imaging using tabletop coherent high-harmonic soft-X-ray beams,” Phys. Rev. Lett., 99 (9), (2007). https://doi.org/10.1103/PhysRevLett.99.098103 Google Scholar

[30] 

Sandberg, R. L., Song, C., Wachulak, P. W., Raymondson, D. A., Paul, A., Amirbekian, B., Lee, E., Sakdinawat, A. E., La-O-Vorakiat, C., Marconi, M. C., Menoni, C. S., Murnane, M. M., Rocca, J. J., Kapteyn, H. C. and Miao, J., “High numerical aperture tabletop soft x-ray diffraction microscopy with 70-nm resolution,” in Proc. Natl. Acad. Sci. U. S. A, (2008). Google Scholar

[31] 

Seaberg, M. D., Adams, D. E., Townsend, E. L., Raymondson, D. A., Schlotter, W. F., Liu, Y., Menoni, C. S., Rong, L., Chen, C.-C., Miao, J., Kapteyn, H. C. and Murnane, M. M., “Ultrahigh 22 nm resolution coherent diffractive imaging using a desktop 13 nm high harmonic source,” Opt. Express, 19 (23), (2011). https://doi.org/10.1364/OE.19.022470 Google Scholar

[32] 

Sandberg, R. L., Raymondson, D. a., La-o-vorakiat, C., Paul, A., Raines, K. S., Miao, J., Murnane, M. M., Kapteyn, H. C. and Schlotter, W. F., “Tabletop soft-x-ray Fourier transform holography with 50 nm resolution,” Opt. Lett, (2009). https://doi.org/10.1364/OL.34.001618 Google Scholar

[33] 

Tadesse, G. K., Eschen, W., Klas, R., Hilbert, V., Schelle, D., Nathanael, A., Zilk, M., Steinert, M., Schrempel, F., Pertsch, T., Tünnermann, A., Limpert, J. and Rothhardt, J., “High resolution XUV Fourier transform holography on a table top,” Sci. Rep., (2018). https://doi.org/10.1038/s41598-018-27030-y Google Scholar

[34] 

TREBES, J. E., BROWN, S. B., CAMPBELL, E. M., MATTHEWS, D. L., NILSON, D. G., STONE, G. F. and WHELAN, D. A., “Demonstration of X-ray Holography with an X-ray Laser,” Science (80-.), 238 (4826), 517 LP –519 (1987). https://doi.org/10.1126/science.238.4826.517 Google Scholar

[35] 

Kim, H. T., Kim, I. J., Kim, C. M., Jeong, T. M., Yu, T. J., Lee, S. K., Sung, J. H., Yoon, J. W., Yun, H., Jeon, S. C., Choi, I. W. and Lee, J., “Single-shot nanometer-scale holographic imaging with laser-driven x-ray laser,” Appl. Phys. Lett., (2011). Google Scholar

[36] 

Malm, E. B., Monserud, N. C., Brown, C. G., Wachulak, P. W., Xu, H., Balakrishnan, G., Chao, W., Anderson, E. and Marconi, M. C., “Tabletop single-shot extreme ultraviolet Fourier transform holography of an extended object,” Opt, Express(2013). Google Scholar

[37] 

Zürch, M., Jung, R., Späth, C., Tümmler, J., Guggenmos, A., Attwood, D., Kleineberg, U., Stiel, H. and Spielmann, C., “Transverse Coherence Limited Coherent Diffraction Imaging using a Molybdenum Soft X-ray Laser Pumped at Moderate Pump Energies,” Sci. Rep., (2017). https://doi.org/10.1038/s41598-017-05789-w Google Scholar

[38] 

Nishikino, M., Tanaka, M., Nagashima, K., Kishimoto, M., Kado, M., Kawachi, T., Sukegawa, K., Ochi, Y., Hasegawa, N. and Kato, Y., “Demonstration of a soft-x-ray laser at 13.9 nm with full spatial coherence,” Phys. Rev. A - At. Mol. Opt. Phys., 68 (6), 4 (2003). https://doi.org/10.1103/PhysRevA.68.061802 Google Scholar

[39] 

Wang, S., Rockwood, A., Wang, Y., Chao, W.-L., Naulleau, P., Song, H., Menoni, C. S., Marconi, M. and Rocca, J. J., “Single-shot large field of view Fourier transform holography with a picosecond plasma-based soft X-ray laser,” Opt. Express, 28 (24), (2020). https://doi.org/10.1364/OE.409815 Google Scholar

[40] 

Larotonda, M. A., Wang, Y., Berrill, M., Luther, B. M., Rocca, J. J., Shakya, M. M., Gilbertson, S. and Chang, Z., “Pulse duration measurements of grazing-incidence-pumped high repetition rate Ni-like Ag and Cd transient soft x-ray lasers,” Opt. Lett., (2006). https://doi.org/10.1364/OL.31.003043 Google Scholar
© (2021) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Shoujun Wang, Alex Rockwood, Yong Wang, Wei-Lun Chao, Patrick Naulleau, Huanyu Song, Carmen S. Menoni, Mario Marconi, and Jorge J. Rocca "Single-shot picosecond resolution Fourier transform holographic microscopy with large field of view using a compact soft x-ray laser", Proc. SPIE 11886, International Conference on X-Ray Lasers 2020, 118860O (8 July 2021); https://doi.org/10.1117/12.2594832
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
Back to Top