Poster + Paper
21 August 2024 Pile-up simulator for XRISM/Xtend
Tomokage Yoneyama, Tsubasa Tamba, Hirokazu Odaka, Aya Bamba, Hiroshi Murakami, Koji Mori, Yukikatsu Terada, Masayoshi Nobukawa, Tsunefumi Mizuno
Author Affiliations +
Conference Poster
Abstract
In X-ray astronomy, most observatories utilize multi-pixel photon-counting devices to obtain spatial, timing, and energy information of X-ray photons radiated by astronomical objects. When a photon-counting device observe a bright source, we face an unavoidable problem called pile-up. Pile-up leads to mistakes in the observational properties of the source, mainly an apparent decrease in the X-ray flux. X-ray telescopes utilizing CCDs as multi-pixel photon-counting devices for imaging and spectroscopy, such as ASCA, Chandra, XMM-Newton, and Suzaku, have operating modes to avoid pile-up for bright sources. X-Ray Imaging and Spectroscopy Mission (XRISM) has two X-ray telescopes, one of which is Xtend, a CCD camera with a wide field-of-view (FOV) of 38 arcmin square. Xtend has three operating modes: full window mode with a frame exposure of ∼4 sec, 1/8 window mode with ∼0.5 sec and reduced FOV, and 1/8 window mode with burst option, whose frame exposure is reduced to ∼0.06 s. Observers need to select the operating mode according to their target fluxes and scientific purposes. We develop the pile-up simulator for Xtend to provide a quantitative assessment of pile-up according to the fluxes, spectra, and shapes of X-ray sources. The simulator is based on the Monte-Carlo simulation utilizing the GEANT4 framework. We derived the 10% pile-up limits for a point source of 7.8, 66.2, and 447.9 counts s−1 for full window, 1/8 window, and 1/8 window mode with burst option, respectively by assuming the Crab spectrum. We present further simulations for a diffuse source and monochromatic spectra.
(2024) Published by SPIE. Downloading of the abstract is permitted for personal use only.
Tomokage Yoneyama, Tsubasa Tamba, Hirokazu Odaka, Aya Bamba, Hiroshi Murakami, Koji Mori, Yukikatsu Terada, Masayoshi Nobukawa, and Tsunefumi Mizuno "Pile-up simulator for XRISM/Xtend", Proc. SPIE 13093, Space Telescopes and Instrumentation 2024: Ultraviolet to Gamma Ray, 130935Y (21 August 2024); https://doi.org/10.1117/12.3018665
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Monte Carlo methods

X-rays

Imaging spectroscopy

X-ray imaging

Photonic devices

X-ray telescopes

Charge-coupled devices

RELATED CONTENT


Back to Top