Paper
1 June 1991 New 2/3-inch MF image pick-up tubes for HDTV camera
Akira Kobayashi, Masayoshi Ishikawa, Takayoshi Suzuki, Morihiro Ikeya, Yasuharu Shimomoto
Author Affiliations +
Proceedings Volume 1449, Electron Image Tubes and Image Intensifiers II; (1991) https://doi.org/10.1117/12.44270
Event: Electronic Imaging '91, 1991, San Jose, CA, United States
Abstract
When HDTV broadcasting starts, HDTV systems will be required more and more in regions of industrial and medical imaging fields. The authors have developed two types of 2/3-inch MF (Mixed Field) Chalnicon (Cadmium-Selenide photoconductive target) for HDTV systems. One of them, No. N4272, is suitable for a three-tube color camera, and black and white camera. Another, No. N4182, is useful for radiation resistant use ($OM 105 Ren/h). Both N4272 and N4182 feature high sensitivity (N4272: 0.16 (mu) A/lx, N4182: 0.15 (mu) A/lx) and high resolution (1,150 TV Lines) which are good enough for required specifications for HDTV imaging devices. In addition to the features mentioned above, it is remarkable that the maximum operating temperature of N4182 is 185 degree(s)F. Thus it is possible to use it for imaging under such conditions as high radiation and high temperature -- circumstances experienced, for instance, in the nuclear power plant.
© (1991) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Akira Kobayashi, Masayoshi Ishikawa, Takayoshi Suzuki, Morihiro Ikeya, and Yasuharu Shimomoto "New 2/3-inch MF image pick-up tubes for HDTV camera", Proc. SPIE 1449, Electron Image Tubes and Image Intensifiers II, (1 June 1991); https://doi.org/10.1117/12.44270
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Electrodes

Image intensifiers

Spatial resolution

Cameras

Transmittance

Glasses

Diodes

RELATED CONTENT


Back to Top