Paper
1 December 1991 Real-time structural integrity monitoring using a passive quadrature demodulated, localized Michelson optical fiber interferometer capable of simultaneous strain and acoustic emission sensing
Edward Tapanes
Author Affiliations +
Abstract
A Michelson Fibre optic sensor (MFOS) is described for in-situ strain and vibration monitoring as well as acoustic emission detection in composite material structures. The phase sensitive fibre optic sensor is localised, all-fibre, and intrinsic. The MFOS was successfully embedded in Keviar/epoxy and graphite/epoxy thermosets as well as graphite/PEEK thermoplastic in order to perform local strain and vibration measurements at the lamina level. A technique allowing acoustic emission detection in parallel with strain and vibration monitoring is illustrated.
© (1991) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Edward Tapanes "Real-time structural integrity monitoring using a passive quadrature demodulated, localized Michelson optical fiber interferometer capable of simultaneous strain and acoustic emission sensing", Proc. SPIE 1588, Fiber Optic Smart Structures and Skins IV, (1 December 1991); https://doi.org/10.1117/12.50188
Lens.org Logo
CITATIONS
Cited by 11 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Sensors

Composites

Fiber optics sensors

Acoustic emission

Fiber optics

Signal detection

Smart structures

RELATED CONTENT

Fiber Optic Sensor Systems For Smart Aerospace Structures
Proceedings of SPIE (January 16 1989)
Fiber Optic Sensors For Composite Monitoring
Proceedings of SPIE (January 16 1989)
Air Force Smart Structures/Skins Program Overview
Proceedings of SPIE (January 16 1989)
Progress toward fiber optic smart structures at UTIAS
Proceedings of SPIE (December 01 1990)

Back to Top