26 June 1992 Point-spread sensitivity analysis for 3-D flourescence microscopy
Chrysanthe Preza, John M. Ollinger, James G. McNally, Lewis J. Thomas Jr.
Author Affiliations +
Proceedings Volume 1660, Biomedical Image Processing and Three-Dimensional Microscopy; (1992) https://doi.org/10.1117/12.59555
Event: SPIE/IS&T 1992 Symposium on Electronic Imaging: Science and Technology, 1992, San Jose, CA, United States
Abstract
Previous empirical results suggest that the use of an experimentally determined point-spread function (PSF) instead of a theoretical one improves reconstructions of three-dimensional (3- D) microscopic objects from optical sections. The microscope's PSF is usually measured by imaging a small fluorescent bead. There is a tradeoff in this measurement: very small beads are dim and bleach rapidly, while larger beads are a poorer approximation to a point source. We have simulated the effect of the bead on the shape of the PSF by convolving a theoretically determined PSF (of a 40 X 1.0 N.A. oil-immersion lens) with spheres of varying diameters. Simulated data were generated with a 3-D phantom and the theoretical PSF, which is defined to be the `true' PSF for the simulation. Reconstructions of the phantom were obtained with each of the theoretical PSFs obtained from the beads using a regularized linear least-squares method. Results show a significant drop (more than 50%) in the signal-to-noise ratio of the reconstructions for beads with diameter larger than 0.22 micrometers . These results suggest that the bead used in the PSF measurement should have a diameter less than 30% of the diameter of the first dark ring of the infocus two-dimensional (2-D) PSF. This study quantifies the tradeoff between the quality of the reconstructions and the bead size used in the PSF measurement.
© (1992) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Chrysanthe Preza, John M. Ollinger, James G. McNally, and Lewis J. Thomas Jr. "Point-spread sensitivity analysis for 3-D flourescence microscopy", Proc. SPIE 1660, Biomedical Image Processing and Three-Dimensional Microscopy, (26 June 1992); https://doi.org/10.1117/12.59555
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Point spread functions

3D image processing

Microscopy

Biomedical optics

Signal to noise ratio

Image processing

Error analysis

Back to Top