1 September 1992 Measured performance of the Hughes 256 x 256 hybrid PtSi imaging device
David L. Perry
Author Affiliations +
Abstract
The Hughes Aircraft Company CRC-365 is a hybrid infrared focal plane array that features a 256 X 256 array of platinum silicide (PtSi) photodiodes. The device was tested in a laboratory environment to determine its performance limits, in the context of MWIR imaging. Test results included the dc transfer function of the multiplexer, power dissipation, dark current, thermal barrier height, Schottky barrier height, blackbody response, saturation charge, signal contrast, Schottky quantum yield, temporal noise, NETD, response nonuniformity, temporal drift, and MRTD. Overall, performance was found to be excellent. Using two-point nonuniformity correction, background-noise-limited photodetection was achieved for a 40 degree target temperature range. Notable problem areas included bandwidth limitations and electrical crosstalk.
© (1992) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
David L. Perry "Measured performance of the Hughes 256 x 256 hybrid PtSi imaging device", Proc. SPIE 1685, Infrared Detectors and Focal Plane Arrays II, (1 September 1992); https://doi.org/10.1117/12.137816
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Sensors

Staring arrays

Black bodies

Multiplexers

Infrared detectors

Electrons

Imaging systems

RELATED CONTENT

Large format high SNR SWIR HgCdTe Si FPA with multiple...
Proceedings of SPIE (April 28 2017)
Performance of a InSb hybrid focal plane array
Proceedings of SPIE (September 01 1990)
Comparative study of SWIR and MWIR Schottky-barrier imagers
Proceedings of SPIE (September 01 1992)

Back to Top