1 May 1994 Temporal behavior of electric field at triple junction and its relation to flashover of bridged vacuum gaps
O. Yamamoto, T. Hara, H. Matsuura, Masayasu Hayashi, K. Yukimura
Author Affiliations +
Proceedings Volume 2259, XVI International Symposium on Discharges and Electrical Insulation in Vacuum; (1994) https://doi.org/10.1117/12.174676
Event: XVI International Symposium on Discharges and Electrical Insulation in Vacuum, 1994, Moscow-St. Petersburg, Russian Federation
Abstract
Temporal change in electric field strength at the insulator-cathode-vacuum interface accompanied by charging of the insulator have been studied by using a 2D Monte Carlo simulation. The study employed cylindrical insulators and conical insulators. Each of the insulators was made of PMMA, polyimide or Al2O3. The field strength with cylindrical insulators show an abrupt increase, and with conical insulators considerable rapid reduction. Dependencies of the field change on the applied voltage height and material are well demonstrated. Flashovers occur after the simulated field change.
© (1994) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
O. Yamamoto, T. Hara, H. Matsuura, Masayasu Hayashi, and K. Yukimura "Temporal behavior of electric field at triple junction and its relation to flashover of bridged vacuum gaps", Proc. SPIE 2259, XVI International Symposium on Discharges and Electrical Insulation in Vacuum, (1 May 1994); https://doi.org/10.1117/12.174676
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Dielectrics

Polymethylmethacrylate

Monte Carlo methods

Aluminum

Interfaces

Computer simulations

Electrodes

Back to Top