Paper
8 December 1997 National Ignition Facility frequency converter development
Charles E. Barker, Jerome M. Auerbach, Chris H. Adams, Stanley E. Bumpas, R. L. Hibbard, Catherine S. Lee, D. H. Roberts, Jack H. Campbell, Paul J. Wegner, Bruno M. Van Wonterghem, John A. Caird
Author Affiliations +
Proceedings Volume 3047, Solid State Lasers for Application to Inertial Confinement Fusion: Second Annual International Conference; (1997) https://doi.org/10.1117/12.294303
Event: Second International Conference on Solid State Lasers for Application to ICF, 1996, Paris, France
Abstract
A preliminary error budget for the third harmonic converter for the National Ignition Facility laser driver has been developed using a root-sum-square-accumulation of error sources. Such a budget sets an upper bound on the allowable magnitude of the various effects that reduce conversion efficiency. Development efforts on crystal mounting technology and crystal quality studies are discussed.
© (1997) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Charles E. Barker, Jerome M. Auerbach, Chris H. Adams, Stanley E. Bumpas, R. L. Hibbard, Catherine S. Lee, D. H. Roberts, Jack H. Campbell, Paul J. Wegner, Bruno M. Van Wonterghem, and John A. Caird "National Ignition Facility frequency converter development", Proc. SPIE 3047, Solid State Lasers for Application to Inertial Confinement Fusion: Second Annual International Conference, (8 December 1997); https://doi.org/10.1117/12.294303
Lens.org Logo
CITATIONS
Cited by 15 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Crystals

Laser crystals

National Ignition Facility

Harmonic generation

Crystallography

Error analysis

Frequency converters

RELATED CONTENT


Back to Top