Paper
24 July 1998 Detective quantum efficiency of direct flat-panel x-ray imaging detectors for fluoroscopy
Author Affiliations +
Abstract
Our goal is to develop a large area, flat panel solid-state detector for fluoroscopy. The detector employs a layer of photoconductor to convert incident x-rays directly to a charge image, which is then read out in real-time using a two dimensional array of thin film transistors (TFTs), or 'active matrix.' In order to guide the design of an optimum fluoroscopic flat-panel detector, a cascaded linear systems model was developed, from which the spatial frequency dependent detective quantum efficiency [DQE(f)] can be obtained. Then DQE(f) was calculated as a function of different detector design parameters, e.g. pixel fill-factor, x-ray exposure, Swank factor, electronic noise, and the calculation was performed for three different x-ray photoconductors: amorphous selenium (a-Se), cadmium zinc telluride (CZT), and lead iodide (PbI2). A critical comparison was made of the advantages and disadvantages of each photoconductor. The results showed that the DQE(0) of all direct detectors has a linear dependence on the pixel fill- factor. For an a-Se layer with an electric field of 10 V/micrometer, DQE(f) is significantly degraded by the electronic noise of the detector, especially at very low x-ray exposure rates (e.g. 0.1 (mu) R/frame). With CZT and PbI2, the detector is more tolerant of electronic noise because of the larger number of charge generated for each absorbed x-ray. We have applied our cascaded linear systems model of the direct, flat-panel detector to fluoroscopy. The theoretical predictions of DQE(f) for different detector parameters, e.g. the type of x-ray photoconductor, fill-factor, and electronic noise, provide a guideline for an optimum detector design for fluoroscopy.
© (1998) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Dylan C. Hunt, Wei Zhao, and John A. Rowlands "Detective quantum efficiency of direct flat-panel x-ray imaging detectors for fluoroscopy", Proc. SPIE 3336, Medical Imaging 1998: Physics of Medical Imaging, (24 July 1998); https://doi.org/10.1117/12.317041
Lens.org Logo
CITATIONS
Cited by 10 scholarly publications and 6 patents.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Photoresistors

Sensors

Quantum efficiency

X-rays

Fluoroscopy

X-ray imaging

Systems modeling

Back to Top