Paper
11 August 1998 Relationship between the cut-on wave number of the transmission spectra and the cut-off wave number of the response spectra
Wenjuan Zhu, Xiaoning Hu, Haimei Gong, Jiaxiong Fang
Author Affiliations +
Abstract
The transmission spectra and response spectra were measured in the same small region of Hg1-xCdxTe material over a temperature range 85K < T < 300K. The relationship between the cut-on wavenumber of the transmission spectra and the cut-off wavenumber of response spectra in the same temperature is shown and the empirical expression is deduced as following: vcutoff equals 2.407 X 10-2 + 1.401vcuton - 1.199vcuton2.
© (1998) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Wenjuan Zhu, Xiaoning Hu, Haimei Gong, and Jiaxiong Fang "Relationship between the cut-on wave number of the transmission spectra and the cut-off wave number of the response spectra", Proc. SPIE 3553, Detectors, Focal Plane Arrays, and Imaging Devices II, (11 August 1998); https://doi.org/10.1117/12.318059