T-Sensors enable the optical detection of clinically significant analytes directly in whole blood. In microfluidic channels, fluids usually show laminar behavior. This allows the movement of different fluidic layers in a channel without mixing other than by diffusion. A sample solution, a detection solution, and a reference solution are introduce din a common channel. Smaller particles such as ions or small proteins diffuse rapidly across the fluid boundaries, whereas larger molecules diffuse more slowly. Large particles show no significant diffusion within the time the flow streams are in contact. Two interface zones are formed between the fluidic layers. The ratio of a property of the two interface zones is a function of the concentration of the analyte. In this paper, we introduce a novel optical geometry to determine absorbance or fluorescence at a number of distinct wavelength ranges, and to perform spectroscopic measurements with 1D or 2D spatial. Resolution in a flow channel. A flow channel is coupled to an optical filter with variable transmission in one or two dimensions, a light source, and a CCD detector. Such a device allows, for example, the absorption- or fluorescence- based detection of a variety of analytes in a T-sensor using a non-color-sensitive spatial detector, while retaining diffusion and reference information provided by the T-sensor principle.
© (1999) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Eric H. Altendorf and Bernhard H. Weigl "Implementation of novel optical detection methods for clinically important blood analytes using microfabricated flow structures (T-Sensors)", Proc. SPIE 3603, Systems and Technologies for Clinical Diagnostics and Drug Discovery II, (21 April 1999); https://doi.org/10.1117/12.346743
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Optical filters

Diffusion

Image filtering

Linear filtering

Statistical analysis

Sensors

Light sources

RELATED CONTENT


Back to Top